Abstract
The purpose of this study was to increase product reliability by improving the durability of the breech block for a 30mm Automatic Gun. The breech block is a key component of a gun that functions as chambering, closing, and extracting. The breech block requires high reliability, which needs to be improved because cracks of a breech block can occur early in operation. Cause analysis confirmed that the crack is caused by repeated impacts. Therefore, the following improvement measures were studied, and the effects were demonstrated using a firing test. The energy of impact absorption was increased by changing the material, and the stress concentration was mitigated by increasing the value of R. In addition, the fatigue life was increased by adding Shot-peening, deleting chromium plating, and changing the forging method. The firing test did not show firing trouble for up to 5,000 rounds. The start timing of the crack was delayed, and the depth was small. Therefore, the improved product was more durable than the existing product. This study can be used as a useful reference when assessing the improvement of the durability of similar products, life study, and criteria for crack acceptance.
본 연구는 30mm 자동포에 적용 중인 폐쇄기의 내구성을 향상시킴으로서 제품의 신뢰성을 증가시키는 것을 목적으로 하고 있다. 연구 대상인 폐쇄기는 왕복운동을 통해 탄의 장전, 약실 폐쇄, 탄피 추출 등의 기능을 하는 포의 주요 구성품으로 높은 신뢰성이 요구되지만 운용 중 폐쇄기 균열이 조기에 발생됨에 따라 개선이 필요하였다. 개선을 위해 원인 분석을 수행하여 균열은 반복적인 충격에 의해 발생함을 확인하였다. 그러하여 다음과 같은 개선방안을 연구하고 입증 사격을 통해 효과를 증명하였다. 개선방안으로 소재 변경으로 충격 흡수에너지를 증가시켰으며 균열 부위의 R 값을 증대하여 응력 집중을 완화하였다. 또한, 쇼트피닝 추가, 크롬도금 삭제, 단조 방법 변경으로 피로수명을 증가시켰다. 개선품의 입증 사격 결과 5,000발까지 사격 장애가 발생하지 않았고 균열의 시작이 늦춰졌으며 그 깊이가 작아졌다. 따라서 개선방안이 적용된 폐쇄기는 기존 제품 보다 내구성이 향상됨을 확인하였다. 본 연구는 유사제품의 내구성 향상, 폐쇄기 균열 성장 속도 예측(수명 연구) 및 균열 허용 기준 설정을 추진할 때 유용한 참고 자료로 활용될 수 있을 것으로 기대된다.