Transducer analysis and signal processing of PMSF with embedded bluff body

  • Yan, Xiao-Xue (School of Electrical and Automation Engineering, Hefei University of Technology) ;
  • Xu, Ke-Jun (School of Electrical and Automation Engineering, Hefei University of Technology) ;
  • Xu, Wei (School of Electrical and Automation Engineering, Hefei University of Technology) ;
  • Yu, Xin-Long (School of Electrical and Automation Engineering, Hefei University of Technology) ;
  • Wu, Jian-Ping (School of Electrical and Automation Engineering, Hefei University of Technology)
  • Received : 2019.01.27
  • Accepted : 2019.07.30
  • Published : 2020.02.25

Abstract

Permanent magnet sodium flowmeter (PMSF) have been used to measure the sodium flow in fast breeder reactors. Due to the effects of irradiation, thermal cycling, time lapse, etc., the magnetic flux density of the PMSF will decrease after being used in the reactor for a period of time. Therefore, it must be calibrated regularly. But some flowmeters that immersed in sodium cannot be removed for an off-line calibration, so the on-line calibration is required. However, the best online calibration accuracy of PMSF using cross-correlation analysis method was 2.0-level without considering the repeatability. In order to further improve this work, the operational principle of the transducer in PMSF is analyzed and the design principle of the transducer is proposed. The transducers were tested on the sodium flow loop to collect the experimental data. The signal characteristics are analyzed from the time and frequency domains, respectively. The cross-correlation analysis method based on biased estimation is adopted to obtain the flow rate. The verification experimental results showed that the measurement accuracy is 1.0-level when the flow velocity is above 0.5 m/s, and the measurement accuracy is 3.0-level when the flow velocity is in the range of 0.2 m/s to 0.5 m/s.

Keywords

References

  1. A.C. Raptis, G.A. Forster, A signal analysis method using cross-correlation of turbulence flow signals to determine calibration of permanent magnet sodium flowmeters, IEEE Trans. Nucl. Sci. 25 (1977) 278-281. https://doi.org/10.1109/TNS.1978.4329316
  2. A. Endou, In service calibration method of electromagnetic flowmeter for LMFBR utilizing cross correlation of output voltage fluctuations, J. Nucl. Sci. Technol. 21 (1984) 501-514. https://doi.org/10.1080/18811248.1984.9731076
  3. H. Araki, Electromagnetic flowmeter in-situ calibration by the flow fluctuation cross correlation method, Trans. Soc. Instrum. Control Eng. 22 (2009) 210-217. https://doi.org/10.9746/sicetr1965.22.210
  4. R. Ramakrishna, P. Anup Kumar, et al., In-situ calibration of permanent magnet flowmeters in PFBR using noise analysis technique, Flow Meas. Instrum. 34 (2013) 76-82. https://doi.org/10.1016/j.flowmeasinst.2013.08.004
  5. Y.Y. Liu, D.L. Chen, J.W. Yang, et al., Correlation sodium flow measurement system design based on labview, Atomic Energy Sci. Technol. 49 (2015) 1865-1869.
  6. Z.-P. Shu, K.-J. Xu, The comparison of biased estimate and unbiased estimate on cross-correlation analysis, J. Electr. Electron. Educ. 39 (2017) 32-34.
  7. L.-A. Xu, Cross-correlation Flow Measurement Technique, first ed., Tianjin University Press, Tianjin, July 1988.
  8. W.-C. Cai, Q.-G. Ying, The New Flow Detection Instrument, first ed., Chemical Industry Press, Beijing, January, 2006.
  9. L.A. Adamovskii, Vortex electromagnetic flow meters for liquid metal coolants, Meas. Tech. 50 (2007) 58-65. https://doi.org/10.1007/s11018-007-0023-5
  10. A. Venugopal, A. Agrawal, S.V. Prabhu, A vortex cross-correlation flowmeter with enhanced turndown ratio, Rev. Sci. Instrum. 85 (2014), 06619.
  11. C.H. Tang, B.B. Dong, B.Z. Ma, Argon Distribution System in Sodium Cooled Fast Reactor, 2011. Pub.No.CN2011/101174479B, Pub. Data: Sep.14.
  12. K.-J. Xu, Y.-Z. Huang, Y.R. Lin, Q. Chen, Signal Analysis and Processing, second ed., Tsinghua University Press, Beijing, December, 2012.
  13. Y.B. Ji, S.R. Qin, et al., Research on the boundary effect problem of finite interval signals, J. Vib. Shock 21 (2002) 108-111. https://doi.org/10.3969/j.issn.1000-3835.2002.04.028

Cited by

  1. Error correction method for in-situ calibration of permanent magnet sodium flowmeter without bluff body based on low-frequency suppression vol.187, 2020, https://doi.org/10.1016/j.measurement.2021.110347