References
- R.F. Barth, J.A. Coderre, M.G.H. Vicente, T.E. Blue, Boron neutron capture therapy of cancer: current status and future prospects, Clin. Cancer Res. 11 (2005) 3987-4002. https://doi.org/10.1158/1078-0432.CCR-05-0035
- R.F. Barth, A.H. Soloway, R.G. Fairchild, R.M. Brugger, Boron neutron capture therapy for cancer, Realities Prospects Canc. 70 (1992) 2995-3007.
- M.F. Hawthorne, The role of chemistry in the development of boron neutron capture therapy of cancer, Angew. Chem. Int. Ed. 32 (1993) 950-984. https://doi.org/10.1002/anie.199309501
- J.A. Coderre, G.M. Morris, The radiation biology of boron neutron capture therapy, Radiat. Res. 151 (1999) 1-18. https://doi.org/10.2307/3579742
- N.S. Hosmane, J.A. Maguire, Y. Zhu, M. Takagaki, Boron and gadolinium neutron capture therapy for cancer treatment, World Sci. (2012) 35-96.
- T. Kurihara, M. Yoshioka, T. Sugano, K. Sennyu, A. Matsumura, H. Matsumoto, H. Kobayashi, F. Inoue, Y. Kiyanagi, H. Nakashima, Construction of a BNCT facility using an 8-MeV high power proton linac in Tokai, in: Conf. Proc, 2012, pp. 4083-4085.
- E. Brunckhorst, Experimental Investigations of the Neutron Contamination in High-Energy Photon Fields at Medical Linear Accelerators, 2009.
- M. Carpano, M. Perona, C. Rodriguez, S. Nievas, M. Olivera, G.A. Santa Cruz, D. Brandizzi, R. Cabrini, M. Pisarev, G.J. Juvenal, Experimental studies of boronophenylalanine (10 BPA) biodistribution for the individual application of boron neutron capture therapy (BNCT) for malignant melanoma treatment, Int. J. Radiat. Oncol. Biol. Phys. 93 (2015) 344-352. https://doi.org/10.1016/j.ijrobp.2015.05.039
- V. Trivillin, M. Garabalino, L. Colombo, S. Gonzalez, R. Farias, A.M. Hughes, E. Pozzi, S. Bortolussi, S. Altieri, M. Itoiz, Biodistribution of the boron carriers boronophenylalanine (BPA) and/or decahydrodecaborate (GB-10) for Boron Neutron Capture Therapy (BNCT) in an experimental model of lung metastases, Appl. Radiat. Isot. 88 (2014) 94-98. https://doi.org/10.1016/j.apradiso.2013.11.115
- H. Joensuu, L. Kankaanranta, T. Seppala, I. Auterinen, M. Kallio, M. Kulvik, J. Laakso, J. Vahatalo, M. Kortesniemi, P. Kotiluoto, Boron neutron capture therapy of brain tumors: clinical trials at the Finnish facility using boronophenylalanine, J. Neuro Oncol. 62 (2003) 123-134. https://doi.org/10.1023/A:1023293006617
- L. Kankaanranta, T. Seppala, H. Koivunoro, K. Saarilahti, T. Atula, J. Collan, E. Salli, M. Kortesniemi, J. Uusi-Simola, A. Makitie, Boron neutron capture therapy in the treatment of locally recurred head and neck cancer, Int. J. Radiat. Oncol. Biol. Phys. 69 (2007) 475-482. https://doi.org/10.1016/j.ijrobp.2007.03.039
- Y. Nakagawa, K. Pooh, T. Kobayashi, T. Kageji, S. Uyama, A. Matsumura, H. Kumada, Clinical review of the Japanese experience with boron neutron capture therapy and a proposed strategy using epithermal neutron beams, J. Neuro Oncol. 62 (2003) 87-99. https://doi.org/10.1023/A:1023234902479
- Y. Nakagawa, H. Hatanaka, Boron neutron capture therapy: clinical brain tumor studies, J. Neuro Oncol. 33 (1997) 105-115. https://doi.org/10.1023/A:1005781517624
- C.P. Raaijmakers, M.W. Konijnenberg, L. Dewit, D. Haritz, R. Huiskamp, K. Philipp, A. Siefert, F. Stecher-Rasmussen, B.J. Mijnheer, Monitoring of blood-10B concentration for boron neutron capture therapy using prompt gammaray analysis, Acta Oncol. 34 (1995) 517-523. https://doi.org/10.3109/02841869509094017
- S. Baechler, P. Kudejova, J. Jolie, J.-L. Schenker, N. Stritt, Prompt gamma-ray activation analysis for determination of boron in aqueous solutions, Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrom. Detect. Assoc. Equip. 488 (2002) 410-418. https://doi.org/10.1016/S0168-9002(02)00466-7
- T. Matsumoto, M. Aoki, O. Aizawa, Phantom experiment and calculation for in vivo 10boron analysis by prompt gamma ray spectroscopy, Phys. Med. Biol. 36 (1991) 329. https://doi.org/10.1088/0031-9155/36/3/002
- P.M. af Rosenschold, D. Minarik, C. Ostlund, M. Ljungberg, C. Ceberg, Prompt gamma tomography during BNCT-a feasibility study, J. Instrum. 1 (2006) P05003. https://doi.org/10.1088/1748-0221/1/05/P05003
- Murata, T. Mukai, S. Nakamura, H. Miyamaru, I. Kato, Development of a thick CdTe detector for BNCT-SPECT, Appl. Radiat. Isot. 69 (2011) 1706-1709. https://doi.org/10.1016/j.apradiso.2011.05.014
- M. Manabe, S. Nakamura, I. Murata, Study on measuring device arrangement of array-type CdTe Detector for BNCT-SPECT, Rep. Practical Oncol. Radiother. 21 (2016) 102-107. https://doi.org/10.1016/j.rpor.2015.04.002
- Murata, S. Nakamura, M. Manabe, H. Miyamaru, I. Kato, Characterization measurement of a thick CdTe detector for BNCT-SPECT-Detection efficiency and energy resolution, Appl. Radiat. Isot. 88 (2014) 129-133. https://doi.org/10.1016/j.apradiso.2014.01.023
- J.-Y. Jung, B. Lu, D.-K. Yoon, K.J. Hong, H. Jang, C. Liu, T.S. Suh, Therapy region monitoring based on PET using 478 keV single prompt gamma ray during BNCT: a Monte Carlo simulation study, Phys. Med. 32 (2016) 562-567. https://doi.org/10.1016/j.ejmp.2016.02.010
- S.-m. Park, A. Aalipour, O. Vermesh, J.H. Yu, S.S. Gambhir, Towards clinically translatable in vivo nanodiagnostics, Nat. Rev. Mater. 2 (2017) 17014. https://doi.org/10.1038/natrevmats.2017.14
- J. Dey, M.A. King, Theoretical and numerical study of MLEM and OSEM reconstruction algorithms for motion correction in emission tomography, IEEE Trans. Nucl. Sci. 56 (2009) 2739-2749. https://doi.org/10.1109/TNS.2009.2021765
- Gaitanis, G. Kontaxakis, G. Spyrou, G. Panayiotakis, G. Tzanakos, PET image reconstruction: a stopping rule for the MLEM algorithm based on properties of the updating coefficients, Comput. Med. Imag. Graph. 34 (2010) 131-141. https://doi.org/10.1016/j.compmedimag.2009.07.006
- T. Yokei, H. Shinohara, H. Onishi, Performance evaluation of OSEM reconstruction algorithm incorporating three-dimensional distance-dependent resolution compensation for brain SPECT: a simulation study, Ann. Nucl. Med. 16 (2002) 11-18. https://doi.org/10.1007/BF02995286
- D.-K. Yoon, J.-Y. Jung, T.S. Suh, Application of proton boron fusion reaction to radiation therapy: a Monte Carlo simulation study, Appl. Phys. Lett. 105 (2014) 223507. https://doi.org/10.1063/1.4903345
- D.K. Yoon, J.Y. Jung, K. Jo Hong, K. Sil Lee, T. Suk Suh, GPU-based prompt gamma ray imaging from boron neutron capture therapy, Med. Phys. 42 (2015) 165-169.
- H.-B. Shin, D.-K. Yoon, J.-Y. Jung, M.-S. Kim, T.S. Suh, Prompt gamma ray imaging for verification of proton boron fusion therapy: a Monte Carlo study, Phys. Med. 32 (2016) 1271-1275. https://doi.org/10.1016/j.ejmp.2016.05.053
- D.-K. Yoon, J.-Y. Jung, S.-M. Han, T.S. Suh, Statistical analysis for discrimination of prompt gamma ray peak induced by high energy neutron: Monte Carlo simulation study, J. Radioanal. Nucl. Chem. 303 (2015) 859-866. https://doi.org/10.1007/s10967-014-3572-5
- A. Valda, D. Minsky, A. Kreiner, A. Burlon, H. Somacal, Development of a tomographic system for online dose measurements in BNCT (Boron Neutron Capture Therapy), Braz. J. Phys. 35 (2005) 785-788. https://doi.org/10.1590/S0103-97332005000500017
- D.M. Minsky, A. Valda, A. Kreiner, S. Green, C. Wojnecki, Z. Ghani, First tomographic image of neutron capture rate in a BNCT facility, Appl. Radiat. Isot. 69 (2011) 1858-1861. https://doi.org/10.1016/j.apradiso.2011.01.030
- G. Hu, S. Wang, Y. Li, L. Xu, P. Li, The influence of temperature gradient on energy resolution of Bi 4 Ge 3 O 12 (BGO) crystal, Ceram. Int. 30 (2004) 1665-1668. https://doi.org/10.1016/j.ceramint.2003.12.157
- G. Hull, B. Genolini, M. Josselin, I. Matea, J. Peyre, J. Pouthas, T. Zerguerras, Energy resolution of LaBr 3: Ce in a phoswich configuration with CsI: Na and NaI: Tl scintillator crystals, Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrom. Detect. Assoc. Equip. 695 (2012) 350-353. https://doi.org/10.1016/j.nima.2011.10.023
- M. McClish, P. Dokhale, J. Christian, C. Stapels, E. Johnson, F. Augustine, K.S. Shah, Performance measurements from LYSO scintillators coupled to a CMOS position sensitive SSPM detector, Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrom. Detect. Assoc. Equip. 652 (2011) 264-267. https://doi.org/10.1016/j.nima.2010.08.064
- L.J. Meng, Z. He, Exploring the limiting timing resolution for large volume CZT detectors with waveform analysis, Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrom. Detect. Assoc. Equip. 550 (2005) 435-445. https://doi.org/10.1016/j.nima.2005.04.076
- H. Nishimura, K. Hattori, S. Kabuki, H. Kubo, K. Miuchi, T. Nagayoshi, Y. Okada, R. Orito, H. Sekiya, A. Takada, Development of large area gamma-ray camera with GSO (Ce) scintillator arrays and PSPMTs, Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrom. Detect. Assoc. Equip. 573 (2007) 115-118. https://doi.org/10.1016/j.nima.2006.11.029
- H. Rothfuss, L. Byars, M.E. Casey, M. Conti, L. Eriksson, C. Michel, Energy resolution and absolute detection efficiency for LSO crystals: a comparison between Monte Carlo simulation and experimental data, Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrom. Detect. Assoc. Equip. 580 (2007) 1087-1092. https://doi.org/10.1016/j.nima.2007.06.067
- P.-A. Soderstrom, F. Recchia, J. Nyberg, A. Al-Adili, A. Atac, S. Aydin, D. Bazzacco, P. Bednarczyk, B. Birkenbach, D. Bortolato, Interaction position resolution simulations and in-beam measurements of the AGATA HPGe detectors, Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrom. Detect. Assoc. Equip. 638 (2011) 96-109. https://doi.org/10.1016/j.nima.2011.02.089
- Tengblad, T. Nilsson, E. Nacher, H.T. Johansson, J. Briz, M. Carmona-Gallardo, C. Cruz, V. Gugliermina, A. Perea, J.S. del Rio, LaBr 3 (Ce): LaCl 3 (Ce) phoswich with pulse shape analysis for high energy gamma-ray and proton identification, Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrom. Detect. Assoc. Equip. 704 (2013) 19-26. https://doi.org/10.1016/j.nima.2012.11.094
- J. Trummer, E. Auffray, P. Lecoq, A. Petrosyan, P. Sempere-Roldan, Comparison of LuAP and LuYAP crystal properties from statistically significant batches produced with two different growth methods, Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrom. Detect. Assoc. Equip. 551 (2005) 339-351. https://doi.org/10.1016/j.nima.2005.06.047
- S. Watanabe, T. Tanaka, K. Oonuki, T. Mitani, S.i. Takeda, T. Kishishita, K. Nakazawa, T. Takahashi, Y. Kuroda, M. Onishi, Development of CdTe pixel detectors for Compton cameras, Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrom. Detect. Assoc. Equip. 567 (2006) 150-153. https://doi.org/10.1016/j.nima.2006.05.164
- H. Yang, N. Menaa, F. Bronson, M. Kastner, R. Venkataraman, W. Mueller, Evaluation of a LiI (Eu) neutron detector with coincident double photodiode readout, Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrom. Detect. Assoc. Equip. 652 (2011) 364-369. https://doi.org/10.1016/j.nima.2010.08.119
- M. Kapusta, M. Balcerzyk, M. Moszynski, J. Pawelke, A high-energy resolution observed from a YAP: Ce scintillator, Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrom. Detect. Assoc. Equip. 421 (1999) 610-613. https://doi.org/10.1016/S0168-9002(98)01232-7
- F. Becvar, J. Cizek, L. Lestak, I. Novotny, I. Prochazka, F. Sebesta, A high-resolution BaF 2 positron-lifetime spectrometer and experience with its long-term exploitation, Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrom. Detect. Assoc. Equip. 443 (2000) 557-577. https://doi.org/10.1016/S0168-9002(99)01156-0
- Bartoli, N. Belcari, A. Del Guerra, S. Fabbri, Simultaneous PET/SPECT imaging with the small animal scanner YAP-(S) PET, in: Nuclear Science Symposium Conference Record, 2007. NSS'07. IEEE, IEEE, 2007, pp. 3408-3413.
-
Z. He, R.D. Vigil, Investigation of pixellated
$HgI2{\gamma}$ -ray spectrometers, Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrom. Detect. Assoc. Equip. 492 (2002) 387-401. https://doi.org/10.1016/S0168-9002(02)01127-0 - K.J. Hong, Y. Choi, J.H. Jung, J. Kang, W. Hu, H.K. Lim, Y. Huh, S. Kim, J.W. Jung, K.B. Kim, A prototype MR insertable brain PET using tileable GAPD arrays, Med. Phys. 40 (2013).
- H. Yu, X. Tang, D. Shu, Y. Liu, C. Geng, C. Gong, S. Hang, D. Chen, Influence of neutron sources and 10B concentration on boron neutron capture therapy for shallow and deeper non-small cell lung cancer, Health Phys. 112 (2017) 258-265. https://doi.org/10.1097/HP.0000000000000601
- A.R. Genady, J.A. Ioppolo, M.M. Azaam, E. Mohamed, New functionalized mercaptoundecahydrododecaborate derivatives for potential application in boron neutron capture therapy: synthesis, characterization and dynamic visualization in cells, Eur. J. Med. Chem. 93 (2015) 574-583. https://doi.org/10.1016/j.ejmech.2015.02.033
- R.G. Fairchild, J. Kalef-Ezra, S. Saraf, S. Fiarman, E. Ramsey, L. Wielopolski, B. Laster, F. Wheeler, Installation and testing of an optimized epithermal neutron beam at the Brookhaven Medical Research Reactor (BMRR), in: Neutron Beam Design, Development, and Performance for Neutron Capture Therapy, Springer, 1990, pp. 185-199.
- Y. Eisen, A. Shor, C. Gilath, M. Tsabarim, P. Chouraqui, C. Hellman, E. Lubin, A gamma camera based on CdTe detectors, Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrom. Detect. Assoc. Equip. 380 (1996) 474-478. https://doi.org/10.1016/S0168-9002(96)00364-6
Cited by
- Feasibility study on image reconstruction for single-photon emission computed tomography with limited projections by neural networks vol.986, 2020, https://doi.org/10.1016/j.nima.2020.164700