DOI QR코드

DOI QR Code

Evaluation of Flexural Performance of Reinforced Concrete Shear Walls According to Flexural Retrofit by Wall End Excavating

단부 파쇄형 휨 보강에 따른 철근콘크리트 전단벽 휨 성능 평가

  • 조의진 (한양대학교 대학원) ;
  • 김수용 (한양대학교 대학원) ;
  • 배백일 (한양사이버대학교 디지털건축도시공학과) ;
  • 최창식 (한양대학교 건축공학부)
  • Received : 2020.02.04
  • Accepted : 2020.03.30
  • Published : 2020.04.30

Abstract

The purpose of this study is to analyze the method of retrofitting flexural strength and the flexural performance of retrofitted shear walls. There are various ways to reinforce the flexural strength of reinforced concrete shear wall structural systems that have already been built, in the case of that, the external force is increased, and the internal force is insufficient. However, there are various problems, such as excessive flexural stiffness after reinforcement and increasing the thickness and length of the wall. We have developed a retrofit method to solve these problems. The wall end is excavated to place the required vertical rebars, and concrete is poured after placing rebars. This is the same concept as creating wall end boundary elements later on. We also studied the anchorage method of reinforcement and the interaction method between the retrofitting end and the existing wall. The flexural test results for the reinforced concrete shear wall using the studied retrofit method can be predicted according to the sectional analysis and FEM analysis, and there are differences in the plastic hinge length, crack propagation, stiffness degradation and energy dissipation due to the bending depending on the vertical rebar ratio of wall end.

Keywords

Acknowledgement

Supported by : 국토교통부

이 논문은 국토교통부 R&D 주거환경연구사업의 연구비지원(20RERP-B099826-06)에 의해 수행되었습니다.

References

  1. Architectural Institute of Korea(AIK). (2016). Korean Building Code and Commentary, Seoul, Architecture Institute of Korean, Kimoondang Publishing Company. (In Korean)
  2. Asplund, B. S. (1949). Strengthening Bridge Slabs with Grouted Reinforcement. ACI Journal Proceedings, 45(1), 397-406.
  3. Attard, M. M., & Setunge, S. (1996). Stress-strain relationship of confined and unconfined concrete. ACI Materials Journal, 93(5), 432-442.
  4. Bohl, A., & Adebar, P. (2011). Plastic hinge lengths in high-rise concrete shear walls. ACI Structural Journal, 108(2).
  5. Chun, Y.S., Lee, K.H., Lee, H.W., Park, Y.E., & Song, J.K. (2013). Seismic Performance of Special Shear Wall Structural System with Effectively Reduced Reinforcement Detail. Journal of the Korea Concrete Institute, 25(3), 271-281. https://doi.org/10.4334/JKCI.2013.25.3.271
  6. De Lorenzis, L., & Teng, J. G. (2007). Near-surface mounted FRP reinforcement: An emerging technique for strengthening structures. Composites Part B: Engineering, 38(2), 119-143. https://doi.org/10.1016/j.compositesb.2006.08.003
  7. Kazaz, I. (2013). Analytical study on plastic hinge length of structural walls. Journal of Structural Engineering (United States), 139(11), 1938-1950. https://doi.org/10.1061/(ASCE)ST.1943-541X.0000770
  8. Korean Agency for Technology and Standards. (2019). Standard test method for making and curing concrete specimens, KS F 2403. (in Korean)
  9. Korean Agency for Technology and Standards. (2017). Standard test method for compressive strength of concrete, KS F 2405. (in Korean)
  10. Korean Agency for Technology and Standards. (2017). Standard test method for static modulus of elasticity and Poisson's ratio in compression of cylindrical concrete specimens, KS F 2438. (in Korean)
  11. Korean Agency for Technology and Standards. (2019). Steel bars for concrete reinforcement, KS D 3504. (in Korean)
  12. Korean Agency for Technology and Standards. (2017). Welding - Welding of reinforcing steel - Part 1:Load-bearing welded joints, KS B ISO 17660-1:2006. (in Korean)
  13. Panagiotakos, T. B., & Fardis, M. N. (2001). Deformations of reinforced concrete members at yielding and ultimate. Structural Journal, 98(2), 135-148.
  14. Park, R., & Paulay, T. (1975). Reinforced concrete structures. John Wiley & Sons, 244-250.
  15. Paulay, T, & Priestley, M. J. N. (1992). Seismic design of reinforced concrete and masonry buildings. John Wiley & Sons, Inc, 142-402.
  16. Paulay, T, & Priestley, M. J. N. (1993). Stability of ductile structural walls. Structural Journal, 90(4), 385-392.
  17. Wong, P. S., Vecchio, F. J., & Trommels, H. (2013). Vector2 & Formworks user's manual second edition. University of Toronto, Canada.