참고문헌
- EPRI, 2010, "Fuel Reliability Monitoring and Failure Evaluation Handbook," Electric Power Research Institute, California, 1019107/Revision 2
- NRC, 2018, "Noble Fission Gas Release During Spent Fuel Cask Loading Operations," Nuclear Regulatory Commission, Washington, Information Notice 2018-01
- IAEA, 2010, "Review of Fuel Failures in Water Cooled Reactors,", International Atomic Energy Agency, Vienna, NF-T-3.6IAEA-TECDOC-1345
- Shin, J. C., Yang, J. D., Sung, U. H., Ryu, S, W., Park, Y. W., 2020, "Technology Trends in Spent Nuclear Fuel Cask and Dry Storage," Trans, of the KPVP, Vol. 16, No. 1, pp. 110-116. doi: http://dx.doi.org/10.20466/KPVP.2020.16.1.110
- Song, T. Y., 2014, "A Study on the Work Management Method Considering Risks in Nuclear Power Plants," Trans, of the KPVP, Vol. 10, No. 1, pp. 37-43
- Kim, S. H., 2010, "Incore Fuel Management," Hyungseul Press, ISBN978-472-4462-6 93430
- IAEA, 2009, "Management of Damaged Spent Nuclear Fuel,", International Atomic Energy Agency, Vienna, NF-T-3.6
- IAEA, 1997, "Poolside Inspection, Repair,and Reconstitution of LWR Fuel Elements", International Atomic Energy Agency, Vienna, IAEA-TECDOC-1050
- IAEA, 2002, "Fuel Failure in Water Reactors: Causes and Mitigation,", International Atomic Energy Agency, Vienna, IAEA-TECDOC-1345
- Rudling, P. and Ingemansson, T., 2003, "PWR Fuel Failure Management Handbook,", Advanced Nuclear Technology International, Sweden, Report ANTI 03-0039R, Rev. 0
- INPO, 2006, "Review of Fauled Fuel, 2000-2006", Institute of Nuclear Power Operations, Atlanta, INPO-TR-64
- Lee, J. M., Kim, H. A, Kook, D. H., and Kim, Y. S., 2018, "A Review of Factors Influencing the Hydride Reorientation Phenomena in Zirconium Alloy Cladding During Long-Term Dry Storage," Korean J. Met. Mater., Vol. 56, No. 2, pp.79-92, DOI: 10.3365/KJMM.2018.56.2.79
- Smith, M. L., Bignell, L. J., Alexiev, M. and Mp, L., 2009, "Sipping Test : Checking for Failur of Fuel Elements at the OPAL Reactor," Australia, Australian Nuclear Science and Technology Organization, PMB 1 Menai NSW 2234,
- Lee, J, H., Kim, Y.C., and Song T, H., 2012, "Development of CANDU Spent Fuel Bundle Inspection System and Technology," Journal of Nuclear Fuel Cycle and Waste Technology, Vol.11, No.1, pp.31-39. doi:https://doi.org/10.7733/jkrws.2013.11.1.31
- Nuclear Services Leaflet, 2014, "In-mast Sipping Services," Westinghouse Electric Company, NS-FS-0046
- Company Leaflet, 2018, "Mast Sipping," Farmatome, www.faramatome.com
- Knecht, K., Stark, R. and Habeck, K. "Recent Experience with In-Core Sipping Techniques," GENES4/ANP2003, Sept. 15-19, 2003, Kyoto, JAPAN, Paper 1134-1- DOC: 25293
- Company Leaflet, 2012, "Telescope Sipping Services," Westinghouse Electric Company, NS-FS-0053
- Deleryd, R., Fredriksson, E., Ivars, R., and Rosengren, A., 1998, "Optimization of Fuel Leak Detection during Outages," SFM 98-095, ABB Atom AB, Vasteras Sweden
- Nuclear Services Leaflet, 2009, "Vacuum Canister Sipping Services," Westinghouse Electric Company, NS-FS-0052