An Experimental Study on the Performance of Heat Pump Unit Using Geothermal Heat for New Renewable Energy

신재생에너지 지열을 이용한 열펌프유닛의 성능에 관한 실험적 연구

  • JEONG, SOON YOUNG (Clean Energy R&D Department, Korea Institute of Industrial Technology)
  • 정순영 (한국생산기술연구원 청정에너지시스템연구부문)
  • Received : 2020.11.02
  • Accepted : 2020.12.30
  • Published : 2020.12.30

Abstract

This paper presents a experimental study on the performance of the heat pump. Uncertainty of measurement means the degree of uncertainty in the measurement. Therefore, it estimates a section where expected value of the measurement might be within a certain confidence level and suggests a range where measured representative value might be incorrect. Uncertainty of measurement is a parameter that shows characteristics of dispersion of measured value that was reasonably estimated from measured quantity. Measurement result of performance experiment is not a true value but estimated value that was estimated reasonably. Therefore, uncertainty of measurement needs to be calculated and presented with the result of measurement.

Keywords

References

  1. O. K. Gwon, D. A. Cha, C. S. Park, and S. G. Lee, "A study on two-stage compression heat pump for district heating", The Society of Air-Conditioning and Refrigerating Engineers of Korea, Vol. 2011, pp. 471-476.
  2. D. A. Cha, O. K. Gwon, C. S. Park, and S. G. Park, "A study on cooling characteristics of ground source heat pump with variation of heat exchange methods", The Society of Air-Conditioning and Refrigerating Engineers of Korea, 2011, pp. 1093-1096.
  3. Z. Lian, S. Park, and H. Qi, "Analysis on energy consumption of water-loop heat pump system in china", Applied Thermal Engineering, 2005, Vol. 25, No. 1, pp. 73-85, doi: https://doi.org/10.1016/j.applthermaleng.2004.06.002.
  4. C. Y. Cho and J. M. Choi, "Influence of refrigerant charge amount on the performance of a water-to-water type ground source heat pump with a variation of compressor speed and water flow rate", New & Renewable Energy, Vol. 7, No. 4, 2011, pp. 30-36, doi: https://doi.org/10.7849/ksnre.2011.7.4.030.
  5. KS (Korean industrial standards) B (B: machine) 8292, "Water-to-water ground source heat pump unit", Korea, 2015. Retrieved from https://standard.go.kr/KSCI/standardIntro/getStandardSearchList.do.
  6. D. Y. Um, "Consideration of the measurement uncertainty for reliability improvement of surveying results", Korea Society of Surveying, Geodesy, Photogrammetry, and Cartography, 2011, pp. 107-112. Retrieved from UCI(KEPA): I410-ECN-0101-2014-530-003268699.
  7. S. J. Moon and J. H. Chung, "Measurement uncertainty of vibration testing result with including uncertainty of testing facilities", Transactions of the Korean Society for Noise and Vibration Engineering, Vol. 26, No. 7, 2016, pp. 781-786. Retrieved from http://www.dbpia.co.kr/journal/articleDetail?nodeId=NODE07070582. https://doi.org/10.5050/KSNVE.2016.26.7.781