참고문헌
- Aboshosha, H. and El Damatty, A.A. (2014), "Effective technique for the reactions of transmission line conductors under high intensity winds", Wind Struct., 18(3), 235-252. http://dx.doi.org/10.12989/was.2014.18.3.235.
- American Society of Civil Engineers (ASCE), (2010) "Guidelines for electrical transmission line structural loading", ASCE manuals and reports on engineering practice, No. 74, New York, NY, USA.
- American Society of Civil Engineers (ASCE), (1997) "Design of guyed electrical transmission structures", ASCE Manuals and Reports on Engineering Practice, vol. 91, New York, NY, USA.
- American Society of Civil Engineers (ASCE), (2012) "Prestressed Concrete Transmission Pole Structures", ASCE manuals and reports on engineering practice, No. 123, Reston, VA, USA.
- Australian Standard/New Zealand Standard (AS/NZS) 7000, (2010) "Overhead line design detailed procedures", Standards Australia Limited/Standards New Zealand, North Sydney, Australia.
- Australian Wind Alliance, (2016): http://www.windalliance.org.au/
- Choi, E.C.C. (2004), "Field measurement and experimental study of wind speed profile during thunderstorms", J. Wind Eng. Ind. Aerod., 92(3-4), 275-290. https://doi.org/10.1016/j.jweia.2003.12.001.
- Darwish, M., El Damatty A.A. and Hangan, H. (2010), "Dynamic characteristics of transmission line conductors and behaviour under turbulent downburst loading", Wind Struct., 13(4), 327-346. http://dx.doi.org/10.12989/was.2010.13.4.327.
- Darwish, M. and El Damatty, A.A. (2011), "Behavior of selfsupported transmission line towers under stationary downburst loading", Wind Struct., 14(5), 481-4. https://doi.org/10.12989/was.2011.14.5.481
- Elawady, A. and El Damatty A.A. (2016), "Longitudinal force on transmission towers due to nonsymmetric downburst conductor loads", Eng. Struct., 127, 206-226. https://doi.org/10.1016/j.engstruct.2016.08.030.
- El Damatty, A.A. and Elawady, A. (2018), "Critical load cases for lattice transmission line structures subjected to downbursts: Economic implications for design of transmission lines", Eng. Struct., 159, 213-226. https://doi.org/10.1016/j.engstruct.2017.12.043.
- Fujita, T. (1985), "The downburst: microburst and macroburst", SMRP Research Paper 210, University of Chicago, USA.
- Fujita, T. (1990), "Downbursts: meteorological features and wind field characteristics", J. Wind Eng. Ind. Aerod., 36, 75-86. https://doi.org/10.1016/0167-6105(90)90294-M.
- Gast, K.D. and Schroeder, J.L. (2003), "Supercell rear-flank downdraft as sampled in the 2002 thunderstorm outflow experiment", Proceedings of the 11th International Conference on Wind Engineering. ICWEIA, 2233-2240.
- Gere, J.M. and Carter, W.O. (1962), "Critical buckling loads for tapered columns", J. Struct. Div- ASCE, 88(1), 1-12. https://doi.org/10.1061/JSDEAG.0000737
- Hangan, H., Roberts, D., Xu, Z. and Kim, J. (2003), "Downburst simulation. Experimental and numerical challenges", Proceedings of the 11th International Conference on Wind Engineering, Lubbock, TX, USA.
- Holmes, J., Hangan, H., Schroeder, J., Letchford, C. and Orwig, K. (2008), "A forensic study of the Lubbock-Reese downdraft of 2002", Wind Struct., 11(2), 137-152. http://dx.doi.org/10.12989/was.2008.11.2.137.
- Ibrahim, A.M. and El Damatty, A.A., (2014), "Behaviour of Prestressed Concrete Poles under Downburst Loading", Proceeding of ASCE conference, Hamilton, ON, Canada.
- Ibrahim, A.M., El Damatty, A.A. and Elansary A.M. (2017), "Finite element modelling of pre-stressed concrete poles under downbursts and tornadoes", Eng. Struct., 153, 370-382. https://doi.org/10.1016/j.engstruct.2017.10.047.
- Ladubec, C., El Damatty, A.A. and El Ansary, A. (2012), "Effect of geometric nonlinear behaviour of a guyed transmission tower under downburst loading", Proceedings of the International Conference on Vibration, Structural Engineering and Measurement, Shanghai, China, Trans. Tech. Publications, 1240-1249.
- Li, C.Q. (2000), "A stochastic model of severe thunderstorms for transmission line design", Probablist. Eng. Mech., 15(4), 359-364. https://doi.org/10.1016/S0266-8920(99)00037-5.
- McCarthy, P. and Melsness, M. (1996), "Severe weather elements associated with September 5, 1996 hydro tower failures near Grosse".
- Shehata, A., El Damatty, A.A. and Savory, E. (2005), "Finite element modeling of transmission line under downburst wind loading", Finite Elem. Anal. Des., 42(1), 71-89. https://doi.org/10.1016/j.finel.2005.05.005.
- Shehata, A. and El Damatty, A.A. (2007), "Behaviour of guyed transmission line structures under downburst wind loading", Wind Struct., 10(3), 249-268 http://dx.doi.org/10.12989/was.2007.10.3.249.
- Wang, X., Lou, W., Li, H. and Chen, Y. (2009), "Wind-induced dynamic response of high-rise transmission tower under downburst wind load", J. Zhejiang Univ., 43(8), 1520-1525.
- Wolfson, M., DiStefano, J. and Fujita, T. (1985), "Low-altitude wind shear characteristics in the Memphis, TN area", Proceedings of the 14th conference on severe local storms, American Meteorological Society, Indianapolis, IN, USA., 322-7.
- Yang, F. and Zhang, H. (2016), "Two case studies on structural analysis of transmission towers under downburst", Wind Struct., 22(6), 685-701. http://dx.doi.org/10.12989/was.2016.22.6.685.
- Zhang, Y., (2006), "Status quo of wind hazard prevention for transmission lines and countermeasures", East China Electric Power, 34(3), 28-31. https://doi.org/10.3969/j.issn.1001-9529.2006.03.008