DOI QR코드

DOI QR Code

Experimental Study on the Shear Capacity of Continuous Cap-Type Shear Connector

연속 캡 형상 전단연결재의 전단 내력에 관한 실험 연구

  • Received : 2019.05.08
  • Accepted : 2019.06.11
  • Published : 2019.06.15

Abstract

The push-out tests have been conducted on the specimens which consist of the steel beam with U-shape section and the continuous cap-type shear connector. Existing formulas for the elevation of shear connector capacity were investigated on the basis of test results. The shear capacities of continuous cap-type shear connectors distinctly declined as the diameters of side-hole in the shear connector increased. The rebars through side-hole for the transverse reinforcement improved the shear capacity of continuous cap-type connector by 20 to 30 percent. It was not feasible to obtain the appropriate capacity values of continuous cap-type shear connectors made of thin steel plate like those of in this study, using the existing formulas. The new formula for reflecting the shear strength of penetrative bars was proposed based on the shear equation of Eurocode 4. The slip capacities of continuous cap-type shear connectors were shown to exceed the limit value of 6mm for the sufficiently ductile behavior.

Keywords

References

  1. Chae, H. S., Ryoo, J. Y., Chung, K. S., Moon, Y. M., & Choi, S. M., "Experimental Study on Structural Performance of End-reinforced Steel-beam system(Eco-girder)", Journal of Korean Society of Steel Construction, Vol.22, No.6, pp.533-541, 2010
  2. Heo, B. W., Bae, K. W., & Moon, T. S., "Flexural Capacity of the Encased(Slim Floor) Composite Beam with Deep Deck Plate", Journal of Korean Society of Steel Construction, Vol.16, No.2, pp.235-245, 2004
  3. Park, K. S., Heo, B. W., Kwak, M. G., & Bae, K. W., "Experimental Study of the Flexural Behavior of Encased Composite Beam for Residential Buildings", Journal of the Architectural Institute of Korea Structure and Construction, Vol.24, No.12, pp.91-98, 2008
  4. Kim, D. B., Kim, Y. H., Oh, M. H., & Kim, M. H., "Experimental Study on the Flexural Capacity of the Concrete-Filled Composite Beam with Exposed Top Flange", Journal of the Korean Society of Hazard Mitigation, Vol.17, No.4, pp.1-9, 2017 https://doi.org/10.9798/kosham.2017.17.4.1
  5. Lee, M. H., Oh, M. H., Kim, Y. H., Jeong, S. C., & Kim, M. H., "Experimental Study on the Shear Capacity of Slim AU Composite Beam", Journal of Korean Association for Spatial Structures, Vol.17, No.3, pp.99-105, 2017 https://doi.org/10.9712/KASS.2017.17.3.099
  6. Kim, S. B., Hwangbo, C., Lee, T. K., Cho, H. S., & Kim, S. S., "The Shear Strength Evaluation of the New Shear Connector by Push-out Test", Journal of the Korean Society of Hazard Mitigation, Vol.14, No.1, pp.1-10, 2014 https://doi.org/10.9798/KOSHAM.2014.14.1.1
  7. Kim, Y. J., Bae, J. H., Ahn, T. S., & Jang, D. W., "Pushout Test on Welded Angle shear Connectors used in Composite Beams", Journal of Korean Society of Steel Construction, Vol.26, No.3, pp.155-167, 2014 https://doi.org/10.7781/kjoss.2014.26.3.155
  8. Oguejiofor, E. C., & Hosain, M. U., "A parametric study of perfobond rib shear connectors", Canadian Journal of Civil Engineering, Vol.21, No.4, pp.614-625, 1994 https://doi.org/10.1139/l94-063
  9. Medberry, S. B., & Shahrooz, B. M., "Perfobond shear connector for composite construction", Engineering Journal, Vol.39, No.1, pp.1048-1056, 2002
  10. Verissimo, G. S., Paes, J. L. R., Valente, I. B., Cruz, P. J. S., & Fakury, R. H. (2006). Design and dxperimental analysis of a new shear connector for steel and concrete composite structures. Proceedings of the 3rd International Conference on Bridge Maintenance, Safety and Management, Portugal, pp.68-72
  11. Ushijima, Y., Hosaka, T., Mitsuki, K., Watanabe, H., Tachibana, Y., & Hiragi, H. (2001). An experimental study on shear characteristics of perfobond strip and its rational strength equations. Proceedings of the International Symposium on Connections between Steel and Concrete, Germany, pp.1066-1075
  12. Oh, M. H., Lee, M. S., Kim, Y. H., & Kim, M. H., "Experimental Study on the Shear Capacity of Cap Type Shear Connectors With Constant Intervals", Journal of Korean Association for Spatial Structures, Vol.18, No.2, pp.121-128, 2018 https://doi.org/10.9712/KASS.2018.18.2.121
  13. CEN prEN 1994-1-1:2004: Final Version of Editorial Group; Eurocode 4, "Design of composite steel and concrete structures. Part 1.1 : General rules and rules for buildings", Comite Europeen de Nomalisation (CEN), Belgium, 2004
  14. Vinh, C. T. H., Vinh, B, D., Le, V. P. N., Kim, I. T., Ahn, J. H., & Dao, D. K., "Shear Resistance Behaviors of an Newly Puzzle Shape of Crestbond Rib Shear Connector:An Experimental Study", Steel and Composite Structures, Vol.21, No.5, pp.1157-1182, 2016 https://doi.org/10.12989/scs.2016.21.5.1157
  15. Candido-Martins, J. P. S., Costa-Veves, L. F., & Vellasco, P. C. G da S., "Experimental svaluation of the structural response of Perfobond shear connecors", Engineering Structures, Vol.32, No.8, pp.1976-1985, 2010 https://doi.org/10.1016/j.engstruct.2010.02.031