Permanent Sprayed Concrete Tunnel Linings Waterproofed with Bonded Membranes. A Review of the Current State-of-the-art for Hard Rock Conditions

  • Holter, K.G. (Norwegian University of Science and Technology NTNU)
  • Published : 2019.06.22

Abstract

Permanent sprayed concrete tunnel linings waterproofed with bonded membranes have been used at a number of important traffic projects over the last decade. Research has been carried out in several teams in order to increase the understanding of the function, properties and behavior of such linings under different loading and boundary conditions. The basic layout of this lining gives fundamental different system properties compared to the traditional lining systems. The main differences pertain to the groundwater exposure and the resulting hydraulic loading, the response of the concrete and membrane materials to this loading, as well as the geomechanically induced loading of the lining structure. The current understanding of the function and properties of such lining structures is presented in the paper based on review of recent research carried out in Norway, as well as field observations and monitoring carried over a several years. The influence of the water exposure on the final condition of the concrete and membrane materials has proven to be of vital importance for proper material testing and acceptance, assessments of the mechanical contribution of the bonded membrane, as well as assessments of the longterm durability of such linings. Obtaining realistic material parameters for the concrete and membrane materials subject to the boundary conditions posed by the groundwater exposure in an undrained structure is emphasized. Finally, some recent results from currently ongoing research on such linings, particularly the hydraulic response of the rock mass and the long term behavior of the concrete and membrane materials are presented.

Keywords

References

  1. Bane NOR (2018). Technical Specifications (in Norwegian, Teknisk regelverk), www.banenor.no/teknisk regelverk.
  2. Ericsson, L. O., Christiansson, R., Hansson, K.; Butron, C., Lehtmaki, T., Sigurdsson, O.; Thorn, J.; & Kinnbom, K. 2015. A demonstration project on controlling and verifying the excavation-damaged zone. Experience from the Aspo Hard Rock Laboratory. Swedish Nuclear Fuel and Waste Company. Report no R-14-30
  3. Holter, K. G. 2014. Loads on sprayed waterproof tunnel linings in jointed hard rock.
  4. Holter, K. G., 2015. Properties of waterproof sprayed concrete tunnel linings. PhD thesis, Norwebian University of Technology and Science, Trondheim, ISBN: 978-82-326-1050-1.
  5. Holter, K. G., Geving, S. 2016. Moisture transport through sprayed concrete tunnel linings. Rock Mechanics and Rock Engineering, 2016, Vol 49/1, pp 243-272. https://doi.org/10.1007/s00603-015-0730-1
  6. Holter, K. G., Smeplass, S., Jacobsen S. 2016. Freeze-thaw resistance of sprayed concrete in tunnel linings. Materials and Structures, Vol 49, pp 3075-3093. https://doi.org/10.1617/s11527-015-0705-4
  7. Holter, K. G. 2016. Performance of EVA-based membranes for SCL in hard rock. Rock Mechanics and Rock Engineering, Vol 49, pp 1329-1358. https://doi.org/10.1007/s00603-015-0844-5
  8. NPRA Norwegian Public Roads Administration. 2012 Report No 127, Major research and development projects, modern road tunnels. Norwegian Public Roads Administration, Oslo.
  9. Rothlisberger, B. (1993) Sprayed Concrete - the wet mix method considering quality, rebound and dust (in German). Proceedings of the Sprayed Concrete Conference, Alpbach Austria.