Abstract

This study analyzes the low-frequency magnetic shielding effectiveness (SE) of a metal plate, in terms of diffusion and slot effects, by conducting a numerical simulation and implementing an analytical solution. When the metal has a low conductivity, the SE is dominated by the diffusion effect. However, when the conductivity and frequency both increase, the slot has a major influence on the SE. These results can be used as guidelines in the shielding design and SE requirements of electromagnetic pulse protection facilities.

본 논문에서는 확산과 슬롯 효과를 고려한 도체 판의 저주파수 자기장 차폐효과를 수치해석과 해석적인 해를 통해 분석하였다. 도체 판의 전도율이 낮은 경우에는 확산에 의한 투과가 지배적이며, 전도율이 높거나 주파수가 높아지면 표피효과로 인해 확산에 의한 투과는 줄어들고, 슬롯이 있는 경우 슬롯에 의한 투과가 우세함을 확인하였다. 이러한 결과는 향후 고출력 전자파 방호시설의 자기장 차폐설계 및 평가기준에 대한 가이드라인으로 활용될 수 있다.

Keywords

JJPHCH_2019_v30n4_324_f0003.png 이미지

그림 3. 수치해석과 전송선 모델을 이용한 차폐효과 결과 비교(도체 판 두께 t=1 mm) Fig. 3. Comparison of SE calculated by numerical analysis and transmission line model.

JJPHCH_2019_v30n4_324_f0004.png 이미지

그림 4. 슬롯이 없는 도체 판의 전도율 변화에 따른 차폐효과(도체 판 두께 t=1 mm) Fig. 4. SE of a metal plate without a slot as varying its conductivity.

JJPHCH_2019_v30n4_324_f0005.png 이미지

그림 5. 슬롯을 갖는 도체 판의 차폐효과 변화 (도체 판두께 t=1 mm, 전도율 σ =106 S/m) Fig. 5. SE of a metal plate with a slot.

JJPHCH_2019_v30n4_324_f0006.png 이미지

그림 6. 자기장 분포 Fig. 6. Magnetic field distributions.

JJPHCH_2019_v30n4_324_f0007.png 이미지

그림 1. MIL-STD-188-125-1의 차폐효과 평가기준[2] Fig. 1. Shielding effectiveness (SE) requirements of MILSTD-188-125-1[2].

JJPHCH_2019_v30n4_324_f0008.png 이미지

그림 2. 시뮬레이션 구조 Fig. 2. Simulation geometry.

References

  1. 정연춘, 이종경, 권석태, "HEMP 방호시설의 SE 평가방법의 비교," 한국전자파학회논문지, 25(11), pp. 1197-1200, 2014년 11월. https://doi.org/10.5515/KJKIEES.2014.25.11.1197
  2. High-altitude electromagnetic pulse(HEMP) protection for ground-based C41 facilities performing critical, time-urgent missions part 1 fixed facilities, MIL-STD-188-125-1, Apr. 2005.
  3. L. F. Babcock, "Shielding circuits from EMP," IEEE Transactions on Electromagnetic Compatibility, vol. 9, no. 2, pp. 45-48, Sep. 1967. https://doi.org/10.1109/TEMC.1967.4307461
  4. K. Lee, G. Bedrosian, "Diffusive electromagnetic penetration into metallic-enclosures," IEEE Transactions on Antennas and Propagation, vol. 27, no. 2, pp. 194-198, Mar. 1979. https://doi.org/10.1109/TAP.1979.1142064
  5. CST. (2012) Microwave Studio(MWS). Available: www.cst.de.
  6. A. C. D. Whitehouse, "Screening: New wave impedance for the transmission line analogy," in Proceedings of the Institution of Electrical Engineers, Jul. 1969, vol. 116, no. 7, pp. 1159-1164. https://doi.org/10.1049/piee.1969.0216
  7. 장태헌, "EMP 방호용 차폐실 설계 및 구축에 대한 고찰," 한국전자파학회지 전자파기술, 25(3), pp. 48-57, 2014년 5월.