References
- Atsushi, S., Hisakazu, K., Toshinori, K., Mitsuhiro, I., Kazuhiro, W. (2007) A Hetero-core Structured Fiber Optic pH Sensor, Anlytica chim. Acta, 582(1), pp.154-157. https://doi.org/10.1016/j.aca.2006.08.061
- Bartoli, I., Phillips, R., di Scalea, F.L., Salamone, S., Coccia, S., Sikorsky, C.S. (2008) Load Monitoring in Multiwire Strands by Interwire Ultrasonic Measurements, Proc. of SPIE, 6932, pp.1-12.
- Chen, H.-L., Wissawapaisal, K. (2001) Measurement of Tensile Forces in a Seven-Wire Prestressing Strand Using Stress Waves. J. Eng. Mech., 127(6), pp.599-606. https://doi.org/10.1061/(ASCE)0733-9399(2001)127:6(599)
- Glisic, B., Inaudi, D. (2008) Fiber Optic Methods for Structural Health Monitoring, John Wiley & Sons, Ltd., Chichester. p.276.
- Idriss, R.L. (2001) Monitoring of a High Performance Prestressed Concrete Bridge with Embedded Optical Fiber Sensors during Fabrication, Construction and Service, 10th Int. Conf. Struct. Faults & Repair, London, England.
- Inaudi, D., Elamari, A., Pflug, L., Gisin, N., Breguet, J., Vurpillot, S. (1994) Low-Coherence Deformation Sensors for the Monitoring of Civil Engineering Structures, Sensor & Actuators A, 44(2), pp.125-130. https://doi.org/10.1016/0924-4247(94)00797-7
- Kim, H.W., Kim, J.M., Choi, S.Y., Park, S.Y., Lee, H.W. (2015) Long Term Monitoring of Prestressing Tension Force in Post-Tension UHPC Bridge using Fiber Optical FBG Sensor, J. Comput. Struct. Eng. Inst. Korea, 28(6), pp.699-706. https://doi.org/10.7734/COSEIK.2015.28.6.699
- Kim, Y.B. (2010) A Basic Study on Development of the Hetero-core Type Fiber Optic Pressure Sensor, Trans. Korea Fluid Power Syst. Soc., 7(2), pp.1-6.
- Ko, J.M., Ni, Y.Q. (2005) Technology Developments in Structural Health Monitoring of Large-Scale Bridges, Eng. Struct. 27(12), pp.1715-1725. https://doi.org/10.1016/j.engstruct.2005.02.021
- Lee, J.H. (2015) Prestressed Concrete Strength Design and Limit State Design, Dong Myeong Publisher, pp.6-11.
- Lee, S.C., Choi, S.Y., Shin, K.J., Kim, J.M., Lee, H.W. (2015) Measurement of Transfer Length for a Seven-Wire Strand with FBG Sensors, J. Comput. Struct. Eng. Inst. Korea, 28(6), pp.707-714. https://doi.org/10.7734/COSEIK.2015.28.6.707
- Maaskant, R., Alavie, T., Measures, R.M., Tadros, G., Rizkalla, S.H., Guha-Thakurta, A. (1997) Fiber-Optic Bragg Grating Sensors for Bridge Monitoring, Cement & Concr. Compos. 19(1), pp.21-33. https://doi.org/10.1016/S0958-9465(96)00040-6
- Measures, R.M., Alavie, A.T., Maaskant, R., Ohn, M., Karr, S., Huang, S. (1994) Bragg Grating Structural Sensing System for Bridge Monitoring, SPIE, 2294, pp.53-60.
- Michiko, N., Kazuhiro, W. (2016) Unconstrained Pulse Pressure Sensing for Health Management based on a Hetero-Core Fiber Optic Sensor, Biomed. Opt. Express. 7(9), pp.3675-3685. https://doi.org/10.1364/BOE.7.003675
- Park, E.T., Choi, K.S., Kim, T.Y., Lee, H.W. (2018) Fundamental Experiment to Verify the Resolution of Hetero-core Fiber Optic Sensor for the Prestress Measurement. J. Comput. Struct. Eng. Inst. Korea, 31(5), pp.259-266. https://doi.org/10.7734/COSEIK.2018.31.5.259
- Sumitro, S., Hida, K., Diouron, T.L. (2003) Structural Health Monitoring Paradigm for Concrete Structures, 28th Conference on Our World in Concrete & Structures, pp.525-532.
- Wang, M.L., Chen, Z. (2000) Magneto-Elastic Permeability Measurement for Stress Monitoring in Steel Tendons and Cables. Proc. SPIE 7th Annual Symposium on Smart Structures and Materials, Health Monitoring of the Highway Transportation Infrastructure, 3995, pp.492-500.