과제정보
연구 과제 주관 기관 : University of Sistan and Baluchestan
참고문헌
- ABAQUS. (2017). User's manual version 2017. Pawtucket, RI: Hibbitt, Karlsson & Sorensen Inc.
- Abidelah, A., Bouchair, A., & Kerdal, D. E. (2012). Experimental and analytical behavior of bolted end-plate connections with or without stiffeners. Journal of Constructional Steel Research, 76, 13-27. https://doi.org/10.1016/j.jcsr.2012.04.004
- AISC, ANSI 341. (2010). Seismic provisions for structural steel buildings. Chicago, IL: American Institute of Steel Construction Inc.
- AISC, ANSI360. (2010). Specification for structural steel buildings. Chicago, IL: American Institute of Steel Construction Inc.
- Azizi Naserabad, A., Ghasemi, M. R., Shabakhty, N., & Ghohani Arab, H. (2015). Patent "prefabricated BBCC connection for using in bolted steel structures". Patent Office, Tehran, Iran, Patent Record Number 86310.
- Chen, C. C., Lin, C. C., & Tsai, C. L. (2004). Evaluation of reinforced connections between steel beams and box columns. Engineering Structures, 26, 1889-1904. https://doi.org/10.1016/j.engstruct.2004.06.017
- Dubina, D., & Stratan, A. (2002). Behavior of welded connections of moment resisting frames beam-to-column joints. Engineering Structures, 24, 1431-1440. https://doi.org/10.1016/S0141-0296(02)00091-3
- Fang, C., Yam, M. C. H., Lam, A. C. C., & Xie, L. (2014). Cyclic performance of extended end-plate connections equipped with shape memory alloy bolts. Journal of Constructional Steel Research, 94, 122-136. https://doi.org/10.1016/j.jcsr.2013.11.008
- Gerami, M., Saberi, H., Saberi, V., & Saedi Daryan, A. (2011). Cyclic behavior of bolted connections with different arrangement of bolts. Journal of Constructional Steel Research, 67, 690-705. https://doi.org/10.1016/j.jcsr.2010.11.011
- Gholami, M., Deylami, A., & Tehranizadeh, M. (2013). Seismic performance of flange plate connections between steel beams and box columns. Journal of Constructional Steel Research, 84, 36-48. https://doi.org/10.1016/j.jcsr.2012.11.011
- Grimsmo, E. L., Clausen, A. H., Langseth, M., & Aalberg, A. (2015). An experimental study of static and dynamic behaviour of bolted end-plate joints of steel. International Journal of Impact Engineering, 85, 132-145. https://doi.org/10.1016/j.ijimpeng.2015.07.001
- Liu, X. C., Pu, S. H., Zhang, A. L., Xu, A. X., Ni, Z., Sun, Y., et al. (2015a). Static and seismic experiment for bolted-welded joint in modularized prefabricated steel structure. Journal of Constructional Steel Research, 115, 417-433. https://doi.org/10.1016/j.jcsr.2015.08.036
- Liu, X. C., Pu, S. H., Zhang, A. L., & Zhan, X. X. (2017). Performance analysis and design of bolted connections in modularized prefabricated steel structures. Journal of Constructional Steel Research, 115, 360-373.
- Liu, X. C., Xu, A. X., Zhang, A. L., Ni, Z., Wang, H. X., & Wu, L. (2015b). Static and seismic experiment for welded joints in modularized prefabricated steel structure. Journal of Constructional Steel Research, 112, 183-195. https://doi.org/10.1016/j.jcsr.2015.05.003
- Maggi, Y. I., Goncalves, R. M., Leon, R. T., & Ribeiro, L. F. L. (2005). Parametric analysis of steel bolted end plate connections using finite element modeling. Journal of Constructional Steel Research, 61, 689-708. https://doi.org/10.1016/j.jcsr.2004.12.001
- Mirghaderi, S. R., Torabian, S., & Keshavarzi, F. (2010). I-beam to box-column connection by a vertical plate passing through the column. Engineering Structures, 32, 2034-2048. https://doi.org/10.1016/j.engstruct.2010.03.002
- Mirghaderil, S. R., & Dehghani Renani, M. (2008). The rigid seismic connection of continuous beams to column. Journal of Constructional Steel Research, 64, 1516-1529. https://doi.org/10.1016/j.jcsr.2008.01.015
- Prinz, G. S., Nussbaumer, A., Borges, L., & Khadka, S. (2014). Experimental testing and simulation of bolted beam-column connections having thick extended endplates and multiple bolts per row. Engineering Structures, 59, 434-447. https://doi.org/10.1016/j.engstruct.2013.10.042
- Rezaeian, A., Jamal-Omidi, M., & Shahidi, F. (2014). Seismic behavior of ConXL rigid connection in box-columns not filled with concrete. Journal of Constructional Steel Research, 97, 79-104. https://doi.org/10.1016/j.jcsr.2013.12.005
- Simoes-da-Silva, L., Lima, L., Vellasco, P., Dendrade, S., & DeCastro, R. A. (2008). Nonlinear dynamic analysis of steel portal frames with semi-rigid connections. Engineering Structures, 30, 2566-2579. https://doi.org/10.1016/j.engstruct.2008.02.011
- Tagawa, H., & Liu, Y. (2014). Stiffening of bolted end-plate connections with steel member assemblies. Journal of Constructional Steel Research, 103, 190-199. https://doi.org/10.1016/j.jcsr.2014.09.005
- Torabian, S., Mirghaderi, S. R., & Keshavarzi, F. (2012). Momentconnection between I-beam and built-up square column by a diagonal through plate. Journal of Constructional Steel Research, 70, 385-401. https://doi.org/10.1016/j.jcsr.2011.10.017
- Wang, J., & Guo, S. (2012). Structural performance of blind bolted end plate joints to concrete-filled thin-walled steel tubular columns. Thin-Walled Structures, 60, 54-68. https://doi.org/10.1016/j.tws.2012.07.006
피인용 문헌
- Design of a Novel Prefabricated Bolted I-Beam to Box-Column Connection Using Numerical Analysis Under Cyclic Load vol.19, pp.5, 2019, https://doi.org/10.1007/s13296-019-00222-6
- Experimental study on all-bolted joint in modularized prefabricated steel structure vol.73, pp.6, 2018, https://doi.org/10.12989/sem.2020.73.6.613
- A review on modular construction for high-rise buildings vol.28, pp.None, 2018, https://doi.org/10.1016/j.istruc.2020.09.070