Acknowledgement
Supported by : Ministry for Health and Welfare, National Cancer Center
References
- Kramer BS, Berg CD, Aberle DR, Prorok PC. Lung cancer screening with low-dose helical CT: results from the National Lung Screening Trial (NLST). J Med Screen 2011;18:109-111 https://doi.org/10.1258/jms.2011.011055
- Lee JW, Kim HY, Goo JM, Kim EY, Lee SJ, Kim TJ, et al. Radiological report of pilot study for the Korean Lung Cancer Screening (K-LUCAS) project: feasibility of implementing lung imaging reporting and data system. Korean J Radiol 2018;19:803-808 https://doi.org/10.3348/kjr.2018.19.4.803
- McNitt-Gray MF. AAPM/RSNA physics tutorial for residents: topics in CT. Radiation dose in CT. Radiographics 2002;22:1541-1553 https://doi.org/10.1148/rg.226025128
- WHO Expert Consultation. Appropriate body-mass index for Asian populations and its implications for policy and intervention strategies. Lancet 2004;363:157-163 https://doi.org/10.1016/S0140-6736(03)15268-3
- Larke FJ, Kruger RL, Cagnon CH, Flynn MJ, McNitt-Gray MM, Wu X, et al. Estimated radiation dose associated with lowdose chest CT of average-size participants in the National Lung Screening Trial. AJR Am J Roentgenol 2011;197:1165-1169 https://doi.org/10.2214/AJR.11.6533
- Aberle DR, Gamsu G, Henschke CI, Naidich DP, Swensen SJ. A consensus statement of the Society of Thoracic Radiology: screening for lung cancer with helical computed tomography. J Thorac Imaging 2001;16:65-68 https://doi.org/10.1097/00005382-200101000-00010
- AAPM Task Group 23 of the Diagnostic Imaging Council CT Committee. The measurement, reporting and management of radiation dose in CT (Report No. 96). College Park, MD: American Association of Physicists in Medicine, 2008
- AAPM Task Group 204. Size-specific dose estimates (SSDE) in pediatric and adult body CT examinations. College Park, MD: American Association of Physicists in Medicine, 2008
- McCollough CH, Leng S, Yu L, Cody DD, Boone JM, McNitt-Gray MF. CT dose index and patient dose: they are not the same thing. Radiology 2011;259:311-316 https://doi.org/10.1148/radiol.11101800
- Christner JA, Braun NN, Jacobsen MC, Carter RE, Kofler JM, McCollough CH. Size-specific dose estimates for adult patients at CT of the torso. Radiology 2012;265:841-847 https://doi.org/10.1148/radiol.12112365
- Israel GM, Cicchiello L, Brink J, Huda W. Patient size and radiation exposure in thoracic, pelvic, and abdominal CT examinations performed with automatic exposure control. AJR Am J Roentgenol 2010;195:1342-1346 https://doi.org/10.2214/AJR.09.3331
- Mulkens TH, Bellinck P, Baeyaert M, Ghysen D, Van Dijck X, Mussen E, et al. Use of an automatic exposure control mechanism for dose optimization in multi-detector row CT examinations: clinical evaluation. Radiology 2005;237:213-223 https://doi.org/10.1148/radiol.2363041220
Cited by
- Rise of the Visible Monkey: Sectioned Images of Rhesus Monkey vol.34, pp.8, 2018, https://doi.org/10.3346/jkms.2019.34.e66
- Characteristics of Recent Articles Published in the Korean Journal of Radiology Based on the Citation Frequency vol.21, pp.12, 2020, https://doi.org/10.3348/kjr.2020.1322
- Coronary artery calcium severity grading on non-ECG-gated low-dose chest computed tomography: a multiple-observer study in a nationwide lung cancer screening registry vol.30, pp.7, 2018, https://doi.org/10.1007/s00330-020-06707-x
- Association of Radiation Doses and Cancer Risks from CT Pulmonary Angiography Examinations in Relation to Body Diameter vol.10, pp.9, 2018, https://doi.org/10.3390/diagnostics10090681
- Radiation Dose from Computed Tomography Scans for Korean Pediatric and Adult Patients vol.46, pp.3, 2018, https://doi.org/10.14407/jrpr.2021.00010