DOI QR코드

DOI QR Code

Optimal Monochromatic Imaging of Spectral Computed Tomography Potentially Improves the Quality of Hepatic Vascular Imaging

  • Yin, Xiao-Ping (Department of CT and MRI, Affiliated Hospital of Hebei University) ;
  • Gao, Bu-Lang (Department of Medical Research, Shijiazhuang First Hospital) ;
  • Li, Cai-Ying (The Second Hospital of Hebei Medical University) ;
  • Zhou, Huan (Department of CT and MRI, Affiliated Hospital of Hebei University) ;
  • Zhao, Liang (Department of CT and MRI, Affiliated Hospital of Hebei University) ;
  • Zheng, Ya-Ting (Department of CT and MRI, Affiliated Hospital of Hebei University) ;
  • Zhao, Yong-Xia (Department of CT and MRI, Affiliated Hospital of Hebei University)
  • Received : 2017.04.19
  • Accepted : 2018.02.01
  • Published : 2018.08.01

Abstract

Objective: To investigate the efficiency of spectral computed tomography (CT) optimal monochromatic images in improving imaging quality of liver vessels. Materials and Methods: The imaging data of 35 patients with abdominal CT angiography were retrospectively analyzed. Hepatic arteries, portal veins, and hepatic veins were reconstructed with mixed energy (quality check, QC), 70 keV and optimal monochromatic mode. Comparative parameters were analyzed including CT value, image noise (IN), contrast-to-noise ratio (CNR), signal-to-noise ratio (SNR), and subjective qualitative analysis. Results: The optimal monochromatic value for assessment of the common hepatic artery, portal vein, and hepatic vein ranged between 49 keV and 53 keV, with a mean of 51 keV. There were statistically significant differences (p < 0.001) among the optimal monochromatic, 70 keV and QC images with regards to the hepatic vascular CT value, IN, CNR, SNR, and subjective qualitative score. CNR of the common hepatic artery in the optimal monochromatic, 70 keV and QC groups was $24.6{\pm}10.9$, $18.1{\pm}8.3$, and $11.6{\pm}4.6$, respectively (p < 0.001) with subjective scores of $4.7{\pm}0.2$, $4.0{\pm}0.3$, and $3.6{\pm}0.4$, respectively (p < 0.001). CNR of the hepatic portal vein was $6.9{\pm}2.7$, $4.3{\pm}1.9$, and $3.0{\pm}2.1$, respectively (p < 0.001) with subjective scores of $4.5{\pm}0.3$, $3.9{\pm}0.4$, and $3.3{\pm}0.3$, respectively (p < 0.001). CNR of the hepatic vein was $5.7{\pm}2.3$, $4.2{\pm}1.9$, and $2.7{\pm}1.4$, respectively with subjective scores of $4.3{\pm}0.3$, $3.8{\pm}0.4$, and $3.2{\pm}0.3$, respectively (p < 0.001). Conclusion: Optimal monochromatic images can lead to improvement in the imaging parameters and optimization of the image quality of the common hepatic artery, hepatic portal vein and hepatic vein compared with conventional mixed kV and with 70 keV datasets.

Keywords

References

  1. Kishi Y, Imamura H, Sugawara Y, Sano K, Kaneko J, Kokudo N, et al. Evaluation of donor vasculobiliary anatomic variations in liver graft procurements. Surgery 2010;147:30-39 https://doi.org/10.1016/j.surg.2009.06.017
  2. Radtke A, Sotiropoulos GC, Sgourakis G, Molmenti EP, Schroeder T, Saner FH, et al. Hepatic venous drainage: how much can we learn from imaging studies? Anatomic-functional classification derived from three-dimensional computed tomography reconstructions. Transplantation 2010;89:1518-1525 https://doi.org/10.1097/TP.0b013e3181dd6bac
  3. Radtke A, Sotiropoulos GC, Sgourakis G, Molmenti EP, Schroeder T, Saner FH, et al. "Anatomical" versus "territorial" belonging of the middle hepatic vein: virtual imaging and clinical repercussions. J Surg Res 2011;166:146-155 https://doi.org/10.1016/j.jss.2009.07.042
  4. Takeishi K, Shirabe K, Yoshida Y, Tsutsui Y, Kurihara T, Kimura K, et al. Correlation between portal vein anatomy and bile duct variation in 407 living liver donors. Am J Transplant 2015;15:155-160 https://doi.org/10.1111/ajt.12965
  5. Goo HW, Goo JM. Dual-energy CT: new horizon in medical imaging. Korean J Radiol 2017;18:555-569 https://doi.org/10.3348/kjr.2017.18.4.555
  6. Song I, Yi JG, Park JH, Kim SM, Lee KS, Chung MJ. Virtual non-contrast CT using dual-energy spectral CT: feasibility of coronary artery calcium scoring. Korean J Radiol 2016;17:321-329 https://doi.org/10.3348/kjr.2016.17.3.321
  7. Xing Y, Zhao Y, Guo N, Pan CX, Azati G, Wang YW, et al. Effect of a novel intracycle motion correction algorithm on dual-energy spectral coronary CT angiography: a study with pulsating coronary artery phantom at high heart rates. Korean J Radiol 2017;18:881-887 https://doi.org/10.3348/kjr.2017.18.6.881
  8. Lv P, Lin XZ, Li J, Li W, Chen K. Differentiation of small hepatic hemangioma from small hepatocellular carcinoma: recently introduced spectral CT method. Radiology 2011;259:720-729 https://doi.org/10.1148/radiol.11101425
  9. He J, Ma X, Wang Q, Fan J, Sun Z. Spectral CT demonstration of the superior mesenteric artery: comparison of monochromatic and polychromatic imaging. Acad Radiol 2014;21:364-368 https://doi.org/10.1016/j.acra.2013.11.004
  10. Xin L, Yang X, Huang N, Du X, Zhang J, Wang Y, et al. The initial experience of the upper abdominal CT angiography using low-concentration contrast medium on dual energy spectral CT. Abdom Imaging 2015;40:2894-2899 https://doi.org/10.1007/s00261-015-0462-4
  11. Zhao LQ, He W, Li JY, Chen JH, Wang KY, Tan L. Improving image quality in portal venography with spectral CT imaging. Eur J Radiol 2012;81:1677-1681 https://doi.org/10.1016/j.ejrad.2011.02.063
  12. Fang CH, You JH, Lau WY, Lai EC, Fan YF, Zhong SZ, et al. Anatomical variations of hepatic veins: three-dimensional computed tomography scans of 200 subjects. World J Surg 2012;36:120-124 https://doi.org/10.1007/s00268-011-1297-y
  13. Wu TC, Lee RC, Chau GY, Chiang JH, Chang CY. Reappraisal of right portal segmental ramification based on 3-dimensional volume rendering of computed tomography during arterial portography. J Comput Assist Tomogr 2007;31:475-480 https://doi.org/10.1097/01.rct.0000243448.41233.75
  14. Zhao LQ, He W, Chen G. Characteristics of paraesophageal varices: a study with 64-row multidetector computed tomography portal venography. World J Gastroenterol 2008;14:5331-5335 https://doi.org/10.3748/wjg.14.5331
  15. Coursey CA, Nelson RC, Boll DT, Paulson EK, Ho LM, Neville AM, et al. Dual-energy multidetector CT: how does it work, what can it tell us, and when can we use it in abdominopelvic imaging? Radiographics 2010;30:1037-1055 https://doi.org/10.1148/rg.304095175
  16. Cheng J, Yin Y, Wu H, Zhang Q, Hua J, Hua X, et al. Optimal monochromatic energy levels in spectral CT pulmonary angiography for the evaluation of pulmonary embolism. PLoS One 2013;8:e63140 https://doi.org/10.1371/journal.pone.0063140
  17. Schueller-Weidekamm C, Schaefer-Prokop CM, Weber M, Herold CJ, Prokop M. CT angiography of pulmonary arteries to detect pulmonary embolism: improvement of vascular enhancement with low kilovoltage settings. Radiology 2006;241:899-907 https://doi.org/10.1148/radiol.2413040128
  18. Takahashi H, Okada M, Hyodo T, Hidaka S, Kagawa Y, Matsuki M, et al. Can low-dose CT with iterative reconstruction reduce both the radiation dose and the amount of iodine contrast medium in a dynamic CT study of the liver? Eur J Radiol 2014;83:684-691 https://doi.org/10.1016/j.ejrad.2013.12.014
  19. Wang X, Zhong Y, Hu L, Xue L, Shi M, Qiu H, et al. A prospective evaluation of the contrast, radiation dose and image quality of contrast-enhanced CT scans of paediatric abdomens using a low-concentration iodinated contrast agent and low tube voltage combined with 70% ASIR algorithm. Int J Clin Pract 2016;70 Suppl 9B:B16-B21 https://doi.org/10.1111/ijcp.12853
  20. Huda W, Scalzetti EM, Levin G. Technique factors and image quality as functions of patient weight at abdominal CT. Radiology 2000;217:430-435 https://doi.org/10.1148/radiology.217.2.r00nv35430
  21. Funama Y, Awai K, Nakayama Y, Kakei K, Nagasue N, Shimamura M, et al. Radiation dose reduction without degradation of low-contrast detectability at abdominal multisection CT with a low-tube voltage technique: phantom study. Radiology 2005;237:905-910 https://doi.org/10.1148/radiol.2373041643
  22. Nakayama Y, Awai K, Funama Y, Hatemura M, Imuta M, Nakaura T, et al. Abdominal CT with low tube voltage: preliminary observations about radiation dose, contrast enhancement, image quality, and noise. Radiology 2005;237:945-951 https://doi.org/10.1148/radiol.2373041655
  23. Wintersperger B, Jakobs T, Herzog P, Schaller S, Nikolaou K, Suess C, et al. Aorto-iliac multidetector-row CT angiography with low kV settings: improved vessel enhancement and simultaneous reduction of radiation dose. Eur Radiol 2005;15:334-341 https://doi.org/10.1007/s00330-004-2575-y
  24. Sagara Y, Hara AK, Pavlicek W, Silva AC, Paden RG, Wu Q. Abdominal CT: comparison of low-dose CT with adaptive statistical iterative reconstruction and routine-dose CT with filtered back projection in 53 patients. AJR Am J Roentgenol 2010;195:713-719 https://doi.org/10.2214/AJR.09.2989
  25. Ma CL, Chen XX, Lei YX, Zhang XR, Jia YJ, Tian X, et al. Clinical value of dual-energy spectral imaging with adaptive statistical iterative reconstruction for reducing contrast medium dose in CT portal venography: in comparison with standard 120-kVp imaging protocol. Br J Radiol 2016;89:20151022 https://doi.org/10.1259/bjr.20151022
  26. Zhao Y, Wu Y, Zuo Z, Suo H, Zhao S, Han J, et al. Application of low concentration contrast medium in spectral CT imaging for CT portal venography. J Xray Sci Technol 2017;25:135-143
  27. Zhu Z, Zhao XM, Zhao YF, Wang XY, Zhou CW. Feasibility study of using gemstone spectral imaging (GSI) and adaptive statistical iterative reconstruction (ASIR) for reducing radiation and iodine contrast dose in abdominal CT patients with high BMI values. PLoS One 2015;10:e0129201 https://doi.org/10.1371/journal.pone.0129201

Cited by

  1. A Glimpse on Trends and Characteristics of Recent Articles Published in the Korean Journal of Radiology vol.20, pp.12, 2019, https://doi.org/10.3348/kjr.2019.0928
  2. Spectral detector CT applications in advanced liver imaging vol.94, pp.1123, 2018, https://doi.org/10.1259/bjr.20201290