DOI QR코드

DOI QR Code

Resistance to sliding in orthodontics: misconception or method error? A systematic review and a proposal of a test protocol

  • Savoldi, Fabio (Department of Orthodontics, Dental School, University of Brescia) ;
  • Papoutsi, Aggeliki (Department of Orthodontics, Medical Faculty, Slovak Medical University) ;
  • Dianiskova, Simona (Department of Orthodontics, Medical Faculty, Slovak Medical University) ;
  • Dalessandri, Domenico (Department of Orthodontics, Dental School, University of Brescia) ;
  • Bonetti, Stefano (Department of Orthodontics, Dental School, University of Brescia) ;
  • Tsoi, James K.H. (Dental Materials Science, Faculty of Dentistry, The University of Hong Kong) ;
  • Matinlinna, Jukka P. (Dental Materials Science, Faculty of Dentistry, The University of Hong Kong) ;
  • Paganelli, Corrado (Department of Orthodontics, Dental School, University of Brescia)
  • Received : 2017.05.24
  • Accepted : 2017.08.09
  • Published : 2018.07.25

Abstract

Resistance to sliding (RS) between the bracket, wire, and ligature has been largely debated in orthodontics. Despite the extensive number of published studies, the lack of discussion of the methods used has led to little understanding of this phenomenon. The aim of this study was to discuss variables affecting RS in orthodontics and to suggest an operative protocol. The search included $PubMed^{(c)}$, $Medline^{(c)}$, and the Cochrane $Library^{(c)}$. References of full-text articles were manually analyzed. English-language articles published between January 2007 and January 2017 that performed an in vitro analysis of RS between the bracket, wire, and ligature were included. Study methods were analyzed based on the study design, description of materials, and experimental setup, and a protocol to standardize the testing methods was proposed. From 404 articles identified from the database search and 242 records selected from published references, 101 were eligible for the qualitative analysis, and six for the quantitative synthesis. One or more experimental parameters were incompatible and a meta-analysis was not performed. Major factors regarding the study design, materials, and experimental setup were not clearly described by most studies. The normal force, that is the force perpendicular to the sliding of the wire and one of the most relevant variable in RS, was not considered by most studies. Different variables were introduced, often acting as confounding factors. A protocol was suggested to standardize testing procedures and enhance the understanding of in vitro findings.

Keywords

References

  1. Besancon RM. The encyclopedia of physics. 3rd ed. New York, NY: Van Nostrand Reinhold Company; 1985.
  2. Jastrzebsky ZD. The nature and properties of engineering materials. 2nd ed. New York, NY: Wiley & Sons; 1976.
  3. Kusy RP, Whitley JQ. Influence of archwire and bracket dimensions on sliding mechanics: derivations and determinations of the critical contact angles for binding. Eur J Orthod 1999;21:199-208. https://doi.org/10.1093/ejo/21.2.199
  4. Kusy RP, Whitley JQ. Friction between different wire-bracket configurations and materials. Semin Orthod 1997;3:166-77. https://doi.org/10.1016/S1073-8746(97)80067-9
  5. Burrow SJ. Friction and resistance to sliding in orthodontics: a critical review. Am J Orthod Dentofacial Orthop 2009;135:442-7. https://doi.org/10.1016/j.ajodo.2008.09.023
  6. Kapur R, Sinha PK, Nanda RS. Comparison of frictional resistance in titanium and stainless steel brackets. Am J Orthod Dentofacial Orthop 1999;116:271-4. https://doi.org/10.1016/S0889-5406(99)70237-4
  7. Southard TE, Marshall SD, Grosland NM. Friction does not increase anchorage loading. Am J Orthod Dentofacial Orthop 2007;131:412-4. https://doi.org/10.1016/j.ajodo.2006.09.037
  8. Braun S, Bluestein M, Moore BK, Benson G. Friction in perspective. Am J Orthod Dentofacial Orthop 1999;115:619-27. https://doi.org/10.1016/S0889-5406(99)70286-6
  9. Yeh CL, Kusnoto B, Viana G, Evans CA, Drummond JL. In vitro evaluation of frictional resistance between brackets with passive-ligation designs. Am J Orthod Dentofacial Orthop 2007;131:704.e11-22.
  10. Muguruma T, Iijima M, Brantley WA, Ahluwalia KS, Kohda N, Mizoguchi I. Effects of third-order torque on frictional force of self-ligating brackets. Angle Orthod 2014;84:1054-61. https://doi.org/10.2319/111913-845.1
  11. Kusy RP. Influence of force systems on archwire-bracket combinations. Am J Orthod Dentofacial Orthop 2005;127:333-42. https://doi.org/10.1016/j.ajodo.2004.07.037
  12. Edwards GD, Davies EH, Jones SP. The ex vivo effect of ligation technique on the static frictional resistance of stainless steel brackets and archwires. Br J Orthod 1995;22:145-53. https://doi.org/10.1179/bjo.22.2.145
  13. Suwa N, Watari F, Yamagata S, Iida J, Kobayashi M. Static-dynamic friction transition of FRP esthetic orthodontic wires on various brackets by suspension-type friction test. J Biomed Mater Res B Appl Biomater 2003;67:765-71.
  14. Kusy RP, Whitley JQ, Prewitt MJ. Comparison of the frictional coefficients for selected archwire-bracket slot combinations in the dry and wet states. Angle Orthod 1991;61:293-302.
  15. Tageldin H, Cadenas de Llano Pérula M, Thevissen P, Celis JP, Willems G. Resistance to sliding in orthodontics: a systematic review. Jacobs J Dent Res 2016;3:034.
  16. Leite VV, Lopes MB, Gonini Júnior A, Almeida MR, Moura SK, Almeida RR. Comparison of frictional resistance between self-ligating and conventional brackets tied with elastomeric and metal ligature in orthodontic archwires. Dental Press J Orthod 2014;19:114-9.
  17. Fleming PS, DiBiase AT, Lee RT. Randomized clinical trial of orthodontic treatment efficiency with self-ligating and conventional fixed orthodontic appliances. Am J Orthod Dentofacial Orthop 2010;137:738-42. https://doi.org/10.1016/j.ajodo.2009.06.023
  18. Savoldi F, Bonetti S, Dalessandri D, Mandelli G, Paganelli C. Incisal apical root resorption evaluation after low-friction orthodontic treatment using two- dimensional radiographic imaging and trigonometric correction. J Clin Diagn Res 2015;9:ZC70-4.
  19. Saunders CR, Kusy RP. Surface topography and frictional characteristics of ceramic brackets. Am J Orthod Dentofacial Orthop 1994;106:76-87. https://doi.org/10.1016/S0889-5406(94)70024-9
  20. Peterson L, Spencer R, Andreasen G. A comparison of friction resistance for Nitinol and stainless steel wire in edgewise brackets. Quintessence Int Dent Dig 1982;13:563-71.
  21. Husain N, Kumar A. Frictional resistance between orthodontic brackets and archwire: an in vitro study. J Contemp Dent Pract 2011;12:91-9.
  22. Kim TK, Kim KD, Baek SH. Comparison of frictional forces during the initial leveling stage in various combinations of self-ligating brackets and archwires with a custom-designed typodont system. Am J Orthod Dentofacial Orthop 2008;133:187.e15-24.
  23. Oz AA, Arici N, Arici S. The clinical and laboratory effects of bracket type during canine distalization with sliding mechanics. Angle Orthod 2012;82:326-32. https://doi.org/10.2319/032611-215.1
  24. Huang TH, Luk HS, Hsu YC, Kao CT. An in vitro comparison of the frictional forces between archwires and self-ligating brackets of passive and active types. Eur J Orthod 2012;34:625-32. https://doi.org/10.1093/ejo/cjr065
  25. Lombardo L, Wierusz W, Toscano D, Lapenta R, Kaplan A, Siciliani G. Frictional resistance exerted by different lingual and labial brackets: an in vitro study. Prog Orthod 2013;14:37. https://doi.org/10.1186/2196-1042-14-37
  26. Williams CL, Khalaf K. Frictional resistance of three types of ceramic brackets. J Oral Maxillofac Res 2014;4:e3.
  27. Amaral MR, Neto PS, Pithon MM, Oliveira DD. Evaluation in vitro of frictional resistance of self-ligating esthetic and conventional brackets. Int J Odontostomatol 2014;8:261-6. https://doi.org/10.4067/S0718-381X2014000200019
  28. Pasha A, Vishwakarma S, Narayan A, Vinay K, Shetty SV, Roy PP. Comparison of frictional forces generated by a new ceramic bracket with the conventional brackets using unconventional and conventional ligation system and the self-ligating brackets: an in vitro study. J Int Oral Health 2015; 7:108-13.
  29. Arici N, Akdeniz BS, Arici S. Comparison of the frictional characteristics of aesthetic orthodontic brackets measured using a modified in vitro technique. Korean J Orthod 2015;45:29-37. https://doi.org/10.4041/kjod.2015.45.1.29
  30. Gandini P, Orsi L, Bertoncini C, Massironi S, Franchi L. In vitro frictional forces generated by three different ligation methods. Angle Orthod 2008;78:917-21. https://doi.org/10.2319/090607-420.1
  31. Kim Y, Cha JY, Hwang CJ, Yu HS, Tahk SG. Com- parison of frictional forces between aesthetic orthodontic coated wires and self-ligation brackets. Korean J Orthod 2014;44:157-67. https://doi.org/10.4041/kjod.2014.44.4.157
  32. Reznikov N, Har-Zion G, Barkana I, Abed Y, Red- lich M. Measurement of friction forces between stainless steel wires and “reduced-friction" self- ligating brackets. Am J Orthod Dentofacial Orthop 2010;138:330-8. https://doi.org/10.1016/j.ajodo.2008.07.025
  33. Ozturk Ortan Y, Yurdakuloglu Arslan T, Aydemir B. A comparative in vitro study of frictional resistance between lingual brackets and stainless steel archwires. Eur J Orthod 2012;34:119-25. https://doi.org/10.1093/ejo/cjq180
  34. Regis S Jr, Soares P, Camargo ES, Guariza Filho O, Tanaka O, Maruo H. Biodegradation of orthodontic metallic brackets and associated implications for friction. Am J Orthod Dentofacial Orthop 2011;140: 501-9. https://doi.org/10.1016/j.ajodo.2011.01.023
  35. Budd S, Daskalogiannakis J, Tompson BD. A study of the frictional characteristics of four commercially available self-ligating bracket systems. Eur J Orthod 2008;30:645-53. https://doi.org/10.1093/ejo/cjn058
  36. Fourie Z, Ozcan M, Sandham A. Effect of dental arch convexity and type of archwire on frictional forces. Am J Orthod Dentofacial Orthop 2009;136:14.e1-7; discussion 14-5. https://doi.org/10.1016/j.ajodo.2009.06.006
  37. Edwards IR, Spary DJ, Rock WP. The effect upon friction of the degradation of orthodontic elastomeric modules. Eur J Orthod 2012;34:618-24. https://doi.org/10.1093/ejo/cjr052
  38. Martins MM, Teixeira AOB, Artese F, Mendes AM. Friction generated by elastomeric ligature with and without polymer coating. Braz Dent Sci 2011;14:9- 12.
  39. Queiroz GV, Ballester RY, Batista De Paiva J, Neto JR, Galon GM. Comparative study of frictional forces generated by NiTi archwire deformation in different orthodontic brackets in vitro evaluation. Dental Press J Orthod 2012;17:45-50. https://doi.org/10.1590/S2176-94512012000400012
  40. Abbassy MA, Bakry AS. The effect of fluoride on beta titanium orthodontics wires' surface texture and friction resistance. Int J Dent Oral Sci 2015;2:47-52.
  41. Uribe MN, Chaparro JPB, Cáceres EJG, Mazo ILP, Quijada ACR. Comparison of resistance to sliding produced by self-ligating brackets and conventional brackets ligated with conventional elastomeric ligature and low-friction ligatures. Rev Fac Odontol Univ Antioq 2012;23:192-206.
  42. Pillai AR, Gangadharan A, Kumar S, Shah A. Comparison of the frictional resistance between archwire and different bracket system: an in vitro study. J Pharm Bioallied Sci 2014;6(Suppl 1):S150-5. https://doi.org/10.4103/0975-7406.137429
  43. Kumar S, Singh S, Hamsa PRR, Ahmed S, Prasanthma, Bhatnagar A, et al. Evaluation of friction in orthodontics using various brackets and archwire combinations-an in vitro study. J Clin Diagn Res 2014;8:ZC33-6. https://doi.org/10.1111/crj.12031
  44. Fathimani M, Melenka GW, Romanyk DL, Toogood RW, Heo G, Carey JP, et al. Development of a standardized testing system for orthodontic sliding mechanics. Prog Orthod 2015;16:14. https://doi.org/10.1186/s40510-015-0087-8
  45. Voudouris JC, Schismenos C, Lackovic K, Kuftinec MM. Self-ligation esthetic brackets with low frictional resistance. Angle Orthod 2010;80:188-94. https://doi.org/10.2319/110608-565.1
  46. Nucera R, Lo Giudice A, Matarese G, Artemisia A, Bramanti E, Crupi P, et al. Analysis of the characteristics of slot design affecting resistance to sliding during active archwire configurations. Prog Orthod 2013;14:35. https://doi.org/10.1186/2196-1042-14-35
  47. Farronato G, Maijer R, Caria MP, Esposito L, Alber- zoni D, Cacciatore G. The effect of Teflon coating on the resistance to sliding of orthodontic archwires. Eur J Orthod 2012;34:410-7. https://doi.org/10.1093/ejo/cjr011
  48. Alió-Sanz JJ, Claros-Stucchi M, Albaladejo A, Ig- lesias-Conde C, Alvarado-Lorenzo A. In vitro com- parative study on the friction of stainless steel wires with and without $Orthospeed^{(R)}$ (JAL 90458) on an inclined plane. J Clin Exp Dent 2016;8:e141-5.
  49. Whitley JQ, Kusy RP. Influence of interbracket distances on the resistance to sliding of orthodontic appliances. Am J Orthod Dentofacial Orthop 2007;132:360-72. https://doi.org/10.1016/j.ajodo.2006.04.032
  50. Tecco S, Di Iorio D, Cordasco G, Verrocchi I, Festa F. An in vitro investigation of the influence of self- ligating brackets, low friction ligatures, and archwire on frictional resistance. Eur J Orthod 2007;29:390-7. https://doi.org/10.1093/ejo/cjm007
  51. Pliska BT, Beyer JP, Larson BE. A comparison of resistance to sliding of self-ligating brackets under an increasing applied moment. Angle Orthod 2011; 81:794-9. https://doi.org/10.2319/111510-666.1
  52. Tecco S, Di Iorio D, Nucera R, Di Bisceglie B, Cor- dasco G, Festa F. Evaluation of the friction of self- ligating and conventional bracket systems. Eur J Dent 2011;5:310-7.
  53. Crincoli V, Perillo L, Di Bisceglie MB, Balsamo A, Serpico V, Chiatante F, et al. Friction forces dur- ing sliding of various brackets for malaligned teeth: an in vitro study. ScientificWorldJournal 2013; 2013:871423.
  54. de Lima Mendonça S, Praxedes Neto OJ, de Olive- ira PT, dos Santos PB, de Sa Leitao Pinheiro FH. Comparison of friction produced by two types of orthodontic bracket protectors. Dental Press J Orthod 2014;19:86-91.
  55. Chang CJ, Lee TM, Liu JK. Effect of bracket bevel design and oral environmental factors on frictional resistance. Angle Orthod 2013;83:956-65. https://doi.org/10.2319/101612-808.1
  56. Galvao MB, Camporesi M, Tortamano A, Domin- guez GC, Defraia E. Frictional resistance in monocrystalline ceramic brackets with conventional and nonconventional elastomeric ligatures. Prog Orthod 2013;14:9. https://doi.org/10.1186/2196-1042-14-9
  57. Inami T, Tanimoto Y, Yamaguchi M, Shibata Y, Nishiyama N, Kasai K. Surface topography, hardness, and frictional properties of GFRP for esthetic orthodontic wires. J Biomed Mater Res B Appl Biomater 2016;104:88-95. https://doi.org/10.1002/jbm.b.33372
  58. Ioi H, Yanase Y, Uehara M, Hara A, Nakata S, Na- kasima A, et al. Frictional resistance in plastic preadjusted brackets ligated with low-friction and conventional elastomeric ligatures. J Orthod 2009;36:17-22; discussion 13. https://doi.org/10.1179/14653120722887
  59. Matarese G, Nucera R, Militi A, Mazza M, Portelli M, Festa F, et al. Evaluation of frictional forces during dental alignment: an experimental model with 3 nonleveled brackets. Am J Orthod Dentofacial Orthop 2008;133:708-15. https://doi.org/10.1016/j.ajodo.2006.06.021
  60. Cordasco G, Lo Giudice A, Militi A, Nucera R, Triolo G, Matarese G. In vitro evaluation of resistance to sliding in self-ligating and conventional bracket systems during dental alignment. Korean J Orthod 2012;42:218-24. https://doi.org/10.4041/kjod.2012.42.4.218
  61. Chung M, Nikolai RJ, Kim KB, Oliver DR. Third-order torque and self-ligating orthodontic bracket-typeeffects on sliding friction. Angle Orthod 2009;79:551-7. https://doi.org/10.2319/0003-3219(2009)079[0551:TTASOB]2.0.CO;2
  62. Heo W, Baek SH. Friction properties according to vertical and horizontal tooth displacement and bracket type during initial leveling and alignment. Angle Orthod 2011;81:653-61. https://doi.org/10.2319/072310-431.1
  63. Meier MJ, Bourauel C, Roehlike J, Reimann S, Keilig L, Braumann B. Friction behavior and other material properties of nickel-titanium and titanium-molybdenum archwires following electrochemical surface refinement. J Orofac Orthop 2014;75:308-18. https://doi.org/10.1007/s00056-014-0225-9
  64. Murayama M, Namura Y, Tamura T, Iwai H, Shimizu N. Relationship between friction force and orthodontic force at the leveling stage using a coa- ted wire. J Appl Oral Sci 2013;21:554-9. https://doi.org/10.1590/1679-775720130325
  65. Seo YJ, Lim BS, Park YG, Yang IH, Ahn SJ, Kim TW, et al. Effect of tooth displacement and vibration on frictional force and stick-slip phenomenon in conventional brackets: a preliminary in vitro mechanical analysis. Eur J Orthod 2015;37:158-63. https://doi.org/10.1093/ejo/cju027
  66. Obaisi NA, Galang-Boquiren MT, Evans CA, Tsay TG, Viana G, Berzins D, et al. Comparison of the transformation temperatures of heat-activated nickel-titanium orthodontic archwires by two diffe- rent techniques. Dent Mater 2016;32:879-88. https://doi.org/10.1016/j.dental.2016.03.017
  67. Savoldi F, Visconti L, Dalessandri D, Bonetti S, Tsoi JKH, Matinlinna JP, et al. In vitro evaluation of the influence of velocity on sliding resistance of stainless steel arch wires in a self-ligating orthodontic bracket. Orthod Craniofac Res 2017;20:119-25.
  68. Natt AS, Sekhon AK, Munjal S, Duggal R, Holla A, Gupta P, et al. A comparative evaluation of static frictional resistance using various methods of ligation at different time intervals: an in vitro study. Int J Dent 2015;2015:407361.
  69. Venâncio FR, Vedovello SAS, Tubel CAM, Degan VV, Lucato AS, Lealdim LN. Effect of elastomeric ligatures on frictional forces between the archwire and orthodontic bracket. Braz J Oral Sci 2013;12:41- 5.
  70. Pacheco MR, Oliveira DD, Neto PS, Jansen WC. Evaluation of friction in self-ligating brackets sub- jected to sliding mechanics: an in vitro study. Dental Press J Orthod 2011;16:107-15. https://doi.org/10.1590/S2176-94512011000100016
  71. Cordasco G, Farronato G, Festa F, Nucera R, Para- zzoli E, Grossi GB. In vitro evaluation of the fric- tional forces between brackets and archwire with three passive self-ligating brackets. Eur J Orthod 2009;31:643-6. https://doi.org/10.1093/ejo/cjp054
  72. Doshi UH, Bhad-Patil WA. Static frictional force and surface roughness of various bracket and wire combinations. Am J Orthod Dentofacial Orthop 2011;139:74-9. https://doi.org/10.1016/j.ajodo.2009.02.031
  73. Sirisaowaluk N, Kravchuk O, Ho CT. The influence of ligation on frictional resistance to sliding during repeated displacement. Aust Orthod J 2006; 22:141-6.
  74. Keith O, Jones SP, Davies EH. The influence of bracket material, ligation force and wear on frictional resistance of orthodontic brackets. Br J Orthod 1993;20:109-15. https://doi.org/10.1179/bjo.20.2.109

Cited by

  1. Functional Coatings for Orthodontic Archwires—A Review vol.13, pp.15, 2018, https://doi.org/10.3390/ma13153257
  2. Self-Assembled PHMB Titanium Coating Enables Anti-Fusobacterium nucleatum Strategy vol.11, pp.10, 2018, https://doi.org/10.3390/coatings11101190
  3. Robust low friction performance of graphene sheets embedded carbon films coated orthodontic stainless steel archwires vol.10, pp.1, 2018, https://doi.org/10.1007/s40544-020-0471-3