DOI QR코드

DOI QR Code

경기도 북부지역 아파트의 지하주차장 실내공기질 변동 특성

The Characteristics of Indoor Air Quality Variation in Underground Parking Lots of Apartments located in Northern Gyeonggi Province

  • 박현구 (경기도보건환경연구원 북부지원) ;
  • 정연훈 (경기도보건환경연구원 북부지원) ;
  • 김병록 (경기도보건환경연구원 북부지원) ;
  • 김진길 (경기도보건환경연구원 북부지원) ;
  • 신형순 (경기도보건환경연구원 북부지원) ;
  • 이상수 (경기도보건환경연구원 북부지원) ;
  • 오조교 (경기도보건환경연구원 북부지원)
  • 투고 : 2018.05.02
  • 심사 : 2018.06.18
  • 발행 : 2018.06.28

초록

Objectives: The study examined indoor air quality during daytime and commute times in underground parking lots in five apartments located in northern Gyeonggi province. Methods: This study examined the temporal characteristics of $PM_{10}$, $CO_2$, CO, HCHO and VOCs in the indoor air quality of the underground parking lots in five apartments. Results: $PM_{10}$ concentration in daytime were ranged from 37.4 to $69.9{\mu}g/m^3$ which complied with the indoor air quality maintenance standard ($200{\mu}g/m^3$) and Gyeonggi province ordinance standard ($180{\mu}g/m^3$). However $PM_{10}$ concentrations in commuting time were in range of $447.3{\sim}944.0{\mu}g/m^3$ that exceeded for both criteria. The $CO_2$, CO and HCHO concentrations complied with the standard. The VOCs indicated high tendency in the order of toluene, xylene, ethylbenzene and benzene. This tendency was more apparent in commuting time than daytime. Conclusion: All indoor parking lots of five apartments were equipped with ventilators. However the most apartment residents did not operate blowers to save electricity and the lack of interest for indoor air quality. In order to improve the indoor air quality of underground parking lots in apartment, operating ventilation system during commuting time is recommended.

키워드

참고문헌

  1. National institute of environmental research, A study on individual exposure assessment according to daily Activities 2010.
  2. Bae HJ. Effects of Short-term Exposure to PM10 and PM2.5 on Mortality in Seoul J Environ Health Sci, 2014; 40(5): 346-354
  3. Baek SO, Kim YS. Characterization of Air Quality in Various Types of Indoor Environments in Urban Areas. Journal of Korea Air Pollution Research Association. 1998; 14(4): 343-360
  4. Ministry of Environment, Indoor Air Quality Control Act for Multi-use Facilities. 2004.
  5. Lee MG, Dong JU, Planning on parking space in co-housing site-Focusing on housing sites in small city, Korea community development society, 2015;40(1): 3-12.
  6. Kim KT, Yang SS, Son BS, Jeon YT, Jang BK, Lee JD, Research about room air quality of department store underground parking lot, The Korean journal of Sanitation 2006; 21(1): 45-51.
  7. Kyonggi Province Ordinance, Regulation No. 3493 on Standards for Indoor Air Quality Maintenance of Multi-use Facilities in Gyeonggi Province 2006.
  8. Ministry of Environment, Indoor air quality process test method. Ministry of Environment Notice 2010: 2010-24.
  9. Song HB , Kwon TK , Hong SH , Baek SO, Air Quality Survey in Large Scale Underground Parking Lots, Korea society environmental engineers, spring academic thesis, 1998; 20(9): 1315-1330.