Acknowledgement
Supported by : (재)바이오 나노헬스가드연구단
References
- Sheeler RD, Houston MS, Radke S, Dale JC, Adamson SC. Accuracy of rapid strep testing in patients who have had recent streptococcal pharyngitis. J Am Board Fam Pract 2002;15:261-265.
- Chin CD, Linder V, Sia SK. Lab-on-a-chip devices for global health: past studies and future opportunities. Lab Chip 2007;7:41-57. https://doi.org/10.1039/B611455E
- Blyth CC, Iredell JR, Dwyer DE. Rapid-test sensitivity for novel swine-origin influenza A (H1N1) virus in humans. N Engl J Med 2009;361:2493. https://doi.org/10.1056/NEJMc0909049
- Booth S, Baleriola C, Rawlinson WD. Comparison of two rapid influenza A/B test kits with reference methods showing high specificity and sensitivity for influenza A infection. J Med Virol 2006;78:619-622. https://doi.org/10.1002/jmv.20584
- DiDomenico N, Link H, Knobel R, et al. COBAS AMPLICOR: fully automated RNA and DNA amplification and detection system for routine diagnostic PCR. Clin Chem 1996;42:1915-1923.
- Bustin SA, Mueller R. Real-time reverse transcription PCR (qRT-PCR) and its potential use in clinical diagnosis. Clin Sci (Lond) 2005;109:365-379. https://doi.org/10.1042/CS20050086
- Yager P, Edwards T, Fu E, et al. Microfluidic diagnostic technologies for global public health. Nature 2006;442:412-418. https://doi.org/10.1038/nature05064
- Lee WG, Kim YG, Chung BG, Demirci U, Khademhosseini A. Nano/Microfluidics for diagnosis of infectious diseases in developing countries. Adv Drug Deliv Rev 2010;62:449-457. https://doi.org/10.1016/j.addr.2009.11.016
- Kettler H, White K, Hawkes S. Mapping the landscape of diagnostics for sexually transmitted infections: key findings and recommendation. Geneva: World Health Organization, 2004.
- St John A. The evidence to support point-of-care testing. Clin Biochem Rev 2010;31:111-119.
- Sharma S, Zapatero-Rodriguez J, Estrela P, O'Kennedy R. Point-of-care diagnostics in low resource settings: present status and future role of microfluidics. Biosensors (Basel) 2015;5:577-601.
- Yager P, Domingo GJ, Gerdes J. Point-of-care diagnostics for global health. Annu Rev Biomed Eng 2008;10:107-144. https://doi.org/10.1146/annurev.bioeng.10.061807.160524
- Martinez AW, Phillips ST, Whitesides GM, Carrilho E. Diagnostics for the developing world: microfluidic paper-based analytical devices. Anal Chem 2010;82:3-10. https://doi.org/10.1021/ac9013989
- Hu J, Wang S, Wang L, et al. Advances in paper-based point-of-care diagnostics. Biosens Bioelectron 2014;54:585-597. https://doi.org/10.1016/j.bios.2013.10.075
- Smit M, Beynon KA, Murdoch DR, Jennings LC. Comparison of the NOW Influenza A & B, NOW Flu A, NOW Flu B, and Directigen Flu A+B assays, and immunofluorescence with viral culture for the detection of influenza A and B viruses. Diagn Microbiol Infect Dis 2007;57:67-70. https://doi.org/10.1016/j.diagmicrobio.2006.11.003
- Rashid H, Shafi S, Haworth E, et al. Value of rapid testing for influenza among Hajj pilgrims. Travel Med Infect Dis 2007;5:310-313. https://doi.org/10.1016/j.tmaid.2007.07.006
- Xu Y, Liu Y, Wu Y, Xia X, Liao Y, Li Q. Fluorescent probe-based lateral flow assay for multiplex nucleic acid detection. Anal Chem 2014;86:5611-5614. https://doi.org/10.1021/ac5010458
- Rohrman BA, Leautaud V, Molyneux E, Richards-Kortum RR. A lateral flow assay for quantitative detection of amplified HIV-1 RNA. PLoS One 2012;7:e45611. https://doi.org/10.1371/journal.pone.0045611
- Mak WC, Sin KK, Chan CP, Wong LW, Renneberg R. Biofunctionalized indigo-nanoparticles as biolabels for the generation of precipitated visible signal in immunodipsticks. Biosens Bioelectron 2011;26:3148-3153. https://doi.org/10.1016/j.bios.2010.12.016
- Wang S, Lifson MA, Inci F, Liang LG, Sheng YF, Demirci U. Advances in addressing technical challenges of point-ofcare diagnostics in resource-limited settings. Expert Rev Mol Diagn 2016;16:449-459. https://doi.org/10.1586/14737159.2016.1142877
- Drancourt M, Michel-Lepage A, Boyer S, Raoult D. The Point-of-care laboratory in clinical microbiology. Clin Microbiol Rev 2016;29:429-447. https://doi.org/10.1128/CMR.00090-15
- Notomi T, Okayama H, Masubuchi H, et al. Loop-mediated isothermal amplification of DNA. Nucleic Acids Res 2000;28:E63. https://doi.org/10.1093/nar/28.12.e63
- Francois P, Tangomo M, Hibbs J, et al. Robustness of a loop-mediated isothermal amplification reaction for diagnostic applications. FEMS Immunol Med Microbiol 2011;62:41-48. https://doi.org/10.1111/j.1574-695X.2011.00785.x
- Henson AM, Carter D, Todd K, Shulman ST, Zheng X. Detection of Streptococcus pyogenes by use of Illumigene group A Streptococcus assay. J Clin Microbiol 2013;51:4207-4209. https://doi.org/10.1128/JCM.01892-13
- Pierce VM, Elkan M, Leet M, McGowan KL, Hodinka RL. Comparison of the Idaho Technology FilmArray system to real-time PCR for detection of respiratory pathogens in children. J Clin Microbiol 2012;50:364-371. https://doi.org/10.1128/JCM.05996-11
- Binnicker MJ, Espy MJ, Irish CL, Vetter EA. Direct detection of influenza A and B viruses in less than 20 minutes using a commercially available rapid PCR assay. J Clin Microbiol 2015;53:2353-2354. https://doi.org/10.1128/JCM.00791-15
- Bell JJ, Selvarangan R. Evaluation of the Alere I influenza A&B nucleic acid amplification test by use of respiratory specimens collected in viral transport medium. J Clin Microbiol 2014;52:3992-3995. https://doi.org/10.1128/JCM.01639-14
- Ioannidis P, Papaventsis D, Karabela S, et al. Cepheid GeneXpert MTB/RIF assay for Mycobacterium tuberculosis detection and rifampin resistance identification in patients with substantial clinical indications of tuberculosis and smear-negative microscopy results. J Clin Microbiol 2011;49:3068-3070. https://doi.org/10.1128/JCM.00718-11
- Buchan BW, Ledeboer NA. Emerging technologies for the clinical microbiology laboratory. Clin Microbiol Rev 2014;27:783-822. https://doi.org/10.1128/CMR.00003-14
- Song SH, Kim E. Rapid Diagnosis of respiratory virus infection. J Lab Med Qual Assur 2007;29:207-210.
- Yoo Y, Sohn JW, Park DW, et al. Clinical evaluation of the SD Bioline influenza virus antigen test for rapid detection of influenza viruses A and B in children and adults during the influenza season. Clin Vaccine Immunol 2007;14:1050-1052. https://doi.org/10.1128/CVI.00465-06
- Cruz AT, Cazacu AC, Greer JM, Demmler GJ. Rapid assays for the diagnosis of influenza A and B viruses in patients evaluated at a large tertiary care children's hospital during two consecutive winter seasons. J Clin Virol 2008;41:143-147. https://doi.org/10.1016/j.jcv.2007.11.006
- Song JH, Park JS, Choi YJ, Kim HJ, Nam HS, Kim YB. Clinical utility of rapid influenza antigen test. J Soonchunhyang Med Sci 2009;15:125-132.
- Son JA, Kim SH, Shin JH, et al. Comparison of the clinical performance of Binax NOW RSV versus multiplex RT-PCR for detection of respiratory syncytial virus. Lab Med Online 2015;5:27-32. https://doi.org/10.3343/lmo.2015.5.1.27
- Kim JS, Choi HJ, Ahn YM, Hwang YO. Clinical usefulness of rapid antigen test on the diagnosis of influenza. Korean J Pediatr 2005;48:1348-1353.
- Gerber MA, Randolph MF, Chanatry J, Wright LL, DeMeo KK, Anderson LR. Antigen detection test for streptococcal pharyngitis: evaluation of sensitivity with respect to true infections. J Pediatr 1986;108(5 Pt 1):654-658. https://doi.org/10.1016/S0022-3476(86)81036-8
- Abdullah N, Hamad MN. Sensitivity and specificity of rapid antigen test in diagnosis of streptococcal upper respiratory tract infection. LMJ 2016;2:6-9.
- Kim S. The evaluation of SD Bioline Strep A rapid antigen test in acute pharyngitis in pediatric clinics. Korean J Lab Med 2009;29:320-323. https://doi.org/10.3343/kjlm.2009.29.4.320
- Lee CK, Cho CH, Woo MK, Nyeck AE, Lim CS, Kim WJ. Evaluation of Sofia fluorescent immunoassay analyzer for influenza A/B virus. J Clin Virol 2012;55:239-243. https://doi.org/10.1016/j.jcv.2012.07.008
- Hassan F, Nguyen A, Formanek A, Bell JJ, Selvarangan R. Comparison of the BD Veritor System for Flu A+B with the Alere BinaxNOW influenza A&B card for detection of influenza A and B viruses in respiratory specimens from pediatric patients. J Clin Microbiol 2014;52:906-910. https://doi.org/10.1128/JCM.02484-13
- Bell J, Bonner A, Cohen DM, et al. Multicenter clinical evaluation of the novel AlereTM i Influenza A&B isothermal nucleic acid amplification test. J Clin Virol 2014;61:81-86. https://doi.org/10.1016/j.jcv.2014.06.001
- Cohen DM, Russo ME, Jaggi P, Kline J, Gluckman W, Parekh A. Multicenter Clinical Evaluation of the Novel Alere i Strep A Isothermal Nucleic Acid Amplification Test. J Clin Microbiol 2015;53:2258-2261. https://doi.org/10.1128/JCM.00490-15
- Gibson J, Schechter-Perkins EM, Mitchell P, et al. Multicenter evaluation of the cobas(R) Liat(R) Influenza A/B & RSV assay for rapid point of care diagnosis. J Clin Virol 2017;95:5-9. https://doi.org/10.1016/j.jcv.2017.08.004
- Binnicker MJ. Multiplex Molecular panels for diagnosis of gastrointestinal infection: performance, result interpretation, and cost-effectiveness. J Clin Microbiol 2015;53:3723-3728. https://doi.org/10.1128/JCM.02103-15
- Kim J, Kim HS, Kim HS, et al. Evaluation of an immunochromatographic assay for the rapid and simultaneous detection of rotavirus and adenovirus in stool samples. Ann Lab Med 2014;34:216-222. https://doi.org/10.3343/alm.2014.34.3.216
- Carroll KC, Buchan BW, Tan S, et al. Multicenter evaluation of the Verigene Clostridium difficile nucleic acid assay. J Clin Microbiol 2013;51:4120-4125. https://doi.org/10.1128/JCM.01690-13
- Buss SN, Leber A, Chapin K, et al. Multicenter evaluation of the BioFire FilmArray gastrointestinal panel for etiologic diagnosis of infectious gastroenteritis. J Clin Microbiol 2015;53:915-925. https://doi.org/10.1128/JCM.02674-14
- Shin S, Kim M, Kim M, et al. Evaluation of the Xpert Clostridium difficile assay for the diagnosis of Clostridium difficile infection. Ann Lab Med 2012;32:355-358. https://doi.org/10.3343/alm.2012.32.5.355
- Stellrecht KA, Espino AA, Maceira VP, et al. Premarket evaluations of the IMDx C. difficile for Abbott m2000 Assay and the BD Max Cdiff Assay. J Clin Microbiol 2014;52:1423-1428. https://doi.org/10.1128/JCM.03293-13
- Orellana-Miguel MA, Alcolea-Medina A, Barrado-Blanco L, Rodriguez-Otero J, Chaves-Sanchez F. Algorithm proposal based on the C. Diff Quik Chek Complete ICT device for detecting Clostridium difficile infection. Enferm Infecc Microbiol Clin 2013;31:97-99. https://doi.org/10.1016/j.eimc.2012.01.003
Cited by
- Guideline for the Antibiotic Use in Acute Gastroenteritis vol.51, pp.2, 2018, https://doi.org/10.3947/ic.2019.51.2.217
- Cost-Effective Multiplex Fluorescence Detection System for PCR Chip vol.21, pp.21, 2018, https://doi.org/10.3390/s21216945
- Cloud-Based Software Architecture for Fully Automated Point-of-Care Molecular Diagnostic Device vol.21, pp.21, 2018, https://doi.org/10.3390/s21216980