초록
LLC resonant converter is popular with industrial fields because it can be achieved high efficiency by zero voltage switching (ZVS). As interest grew, analysis of characteristics in LLC resonant converter have been actively studied. Generally, characteristic of LLC resonant converter is analyzed based on first harmonic approximation(FHA). The FHA analysis represents the characteristics of LLC resonant converter by obtaining the series resonant operation. FHA analysis of LLC resonant converter in load condition is correct. but it is not correct in no load condition. This paper proposed analysis of characteristics considering the parasitic components to overcome the limitation of FHA and analyze no-load characteristics. The validity of the proposed method has been investigated by simulation and experimental results.