• 제목/요약/키워드: No-load condition

Search Result 363, Processing Time 0.022 seconds

Analysis of No-load Characteristics in LLC Resonant Converter (LLC 공진형 컨버터의 무부하 특성 분석)

  • Kwon, Min-Jun;Lee, Woo-Cheol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.3
    • /
    • pp.398-405
    • /
    • 2018
  • LLC resonant converter is popular with industrial fields because it can be achieved high efficiency by zero voltage switching (ZVS). As interest grew, analysis of characteristics in LLC resonant converter have been actively studied. Generally, characteristic of LLC resonant converter is analyzed based on first harmonic approximation(FHA). The FHA analysis represents the characteristics of LLC resonant converter by obtaining the series resonant operation. FHA analysis of LLC resonant converter in load condition is correct. but it is not correct in no load condition. This paper proposed analysis of characteristics considering the parasitic components to overcome the limitation of FHA and analyze no-load characteristics. The validity of the proposed method has been investigated by simulation and experimental results.

A Study on Rotor Eddy Current Loss and Thermal Analysis of PM Synchronous Generator for Wind Turbine (풍력터빈 PM형 동기발전기의 와전류손실과 열 해석에 관한 연구)

  • Choi, Man Soo;Chang, Young Hag;Park, Tae Sik;Jeong, Moon Seon;Moon, Chae Joo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.11
    • /
    • pp.1575-1581
    • /
    • 2014
  • In this paper, eddy current loss, iron loss and heat transfer of PMSG with 2,000kW capacities were analyzed for wind turbine. The PMSG with 3 split magnet was analyzed using ansoft maxwell commercial program and, generator was tested by Back to Back converter with no load condition at laboratory. Rotor surface temperature was measured by Pt100 sensors for investigating heat transfer from rotor to atmosphere. The simulation results shows 27.4kW eddy current loss in no load condition and 50.2kW eddy current loss in rated load condition with 3 split magnet, and also shows 4.3kW iron loss in no load condition and 7.3kW iron loss rated load condition. The heat transfer coefficient of convection between rotor surface and atmosphere was investigated by $9.6W/m^2{\cdot}K$. Therefore the heat transfer from rotor to atmosphere was about 17kW(54%) and from rotor to air-gap was about 14.6kW(46%) in no load condition. It is identified that the cooling system for stator have to include the 46% of iron loss, and heat dissipation structure of rotor surface have to be suggested and designed for efficiency improvement of generator.

The preliminary study of developing strong corrugated box board against aggravated service condition(I) (환경변화에 강한 골판지 개발을 위한 기초연구(제1보))

  • 서영범;오영순
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.30 no.1
    • /
    • pp.29-43
    • /
    • 1998
  • This study was to investigate the effect of .compressive load and cyclic humidity(2$0^{\circ}C$, 65% and 90% RH) on the physical and mechanical properties of corrugated board. Corrugated boards in the study were under compressive load and under cyclic humidity, and their properties were compared to those without load. Results were summarized as follows ; 1 Statistically significant correlation was shown between the ring crush of the boards and the compressive strength of cylinder specimen made from the boards. So we could study the compressive behavior of board with cylinder specimen. 2. The boards under the compressive load increased their moisture content and thickness much more than those without load both in constant and in cyclic RH. 3. The compressive and tensile strength of board samples were inversely and closely proportional to the sheet moisture content regardless of their load and humidity history. 4. The moisture content did not show any significant proportionality to the change of burst strength of boards within this experiment. 5. Board reconditioning in standard condition led to the recovery of the strength loss that had occurred under various load and humidity condition. 6. The handsheets prepared from the boards that had experienced compressive load and cyclic humidity, and those with no-load and 65% RH did not show any significant difference in strength properties. No physical damage or load-carrying properties of the wood fiber were observed by the compressive load and cyclic humidity history.

  • PDF

Study on the Oil Dilution of the Farm Kerosee Engine while Using Impure Fuels (불량연료 사용시 농용등유 엔진의 Oil Dilution 현상에 관한 연구)

  • 김만수;김성래;오세인
    • Journal of Biosystems Engineering
    • /
    • v.2 no.1
    • /
    • pp.1-6
    • /
    • 1977
  • The dilution of crankcase oil with unburned portions of the fuel during operating is one source of the oil contaminations which will reduce engine life.It has been learned that major causes of oil dilution may be the result of using impure fuels which were mixed with water, dust, and some others, but very little was known about this. This study was conducted to develop a more intimate understanding about oil dilution of the farm kerosene engine while using impure fuel mixed with expecially diesel. Fuels being used in this study were 9 kinds of mixed fuels, kerosene and diesel. Farm kerosenen engine of 10 P.S. was tested at no-load of 1000 and 2000 rpm., such as 1/4, 2/4, 3/4, 4/4, and 11/10 loads for understanding about oil dilution of keresene engine.The result of this study are summarized as follows : 1. The amounts of oil dilution of the engine being tested was increased with increase in the applied loads and the contents of diesel in the mixed fuels when using fuels other than kerosenen and diesel, whereas at $D_100$ fuel the comount of oil dilution decreased in some cases. The lowest value was measured to be 20 cc/hr, at $K_90$ fuel of no-load condition, and the highest value to be 293cc/hr. at $K_{10}$ fuel of 4/4 load condition. 2. When the engine was operated at no-load condition, the amount of oil dilution at 100rpm. was much more than at 2000 rpm. 3. Because the fuel consumption and the oil dilution showed a similar tendency along the applied loads, the excessive fuel consumption of engines was supposed to be one of the important factors affecting oil dilution. 4. The temperature of crankcse oil was varied invesely with oil dilution, but they were not thought to be factors to determine each other variable. 5. The tested engine could be operated with high percentage of diesel mixed fuel from no-load condition to fully loaded condition, but it would be impossible to operate the engine for long hous continuously due to excessive speed fluctuation.

  • PDF

The Effect of Ground Condition, Tire Inflation Pressure and Axle Load on Steering Torque (노면상태, 타이어 공기압 및 축하중이 조향력에 미치는 영향)

  • Park W. Y.;Kim S. Y.;Lee C. H.;Choi D. M;Lee S. S.;Lee K. S.
    • Journal of Biosystems Engineering
    • /
    • v.29 no.5 s.106
    • /
    • pp.419-424
    • /
    • 2004
  • In this study, a series of soil bin experiment was carried out to investigate experimentally the effect of the tire inflation pressure and axle load of tire on the steering torque for the off-road condition. The experiment was performed at the three levels of off-road conditions(ground I, ground II and ground III) and on-road condition(ground IV), four levels of tire inflation pressure(120 kPa, 170 kPa, 220 kPa and 270 kPa), and four levels of axle load(1470N, 1960N, 2450N and 2940N). The results of this study are summarized as follows: 1. Steering torque at the off-road conditions were higher than that on the on-road conditions for all levels of tire inflation pressure and axle load. 2. As the axle load increased, steering torque also increased f3r all experimental ground conditions. 3. For the axle load of 1470N the biggest steering torque was measured on the ground condition I, but as the axle load increased to the value of 2940N the biggest steering torque was measured on the ground condition III. From the above results, it was found that for the low axle load, steering torque gets higher on the soft ground condition, but for the high axle load, steering torque gets higher on hard ground condition for whole range of experimental conditions. 4. As the tire inflation pressure decreased, steering torque increased on the on-road condition, but no specific trend was not found at the off-road conditions.

The Studies on the Foot Stability and Kinesiology by Direction of Carry a Load during Gait (보행 시 부하의 위치에 따른 발의 안정성 및 운동학적 분석에 관한 연구)

  • Lee, Sang-Yeol;Bae, Sung-Soo
    • The Journal of Korean Physical Therapy
    • /
    • v.21 no.2
    • /
    • pp.97-101
    • /
    • 2009
  • Purpose: This study examined how the direction of carrying a load affects the foot stability and kinesiology while walking. Methods: The heel rotation, Hallux stiffness, foot balance, metatarsal load, toe out angle, subtalar joint flexibility were measured in 40 adults (men and women) who carried a load back and forth, walking on a 2-meter-long board. The measurement was carried out three times and the mean of the measurements was used to compare the difference between the front, back and the condition without a load. Results: While walking, heel rotation and hallux stiffness occurred most when a front load was applied compared to a back load or no load condition (p<0.05). A metatarsal load also appeared to be the highest with the frond load, but there was no significant difference in the balance of the whole foot. Both the toe out angle and subtalar joint flexibility appeared to increase significantly (p<0.05). Conclusion: Applying the front load causes subtalar joint instability and increases the plantar foot pressure imbalance during walking.

  • PDF

Development of Control Algorithm and Detection of the Small Leakage Current (미소 누전전류 검출 및 차단제어기 설계)

  • 반기종;김낙교
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.53 no.3
    • /
    • pp.161-165
    • /
    • 2004
  • In this paper, we have designed the ground faults detection and interrupting controller at normal condition of AC 120v to 240v rating voltage. Ground faults in electrical network have the characteristics of low current, 60㎐ frequency to 2㎑frequency. The load condition are no load and 20A load. The trip level of the controller is 6㎃ with ground faults. The Controller algorithm is implemented using pic16c71 microprocessor.

A Study on the Change of Physical Capability of Waterproofing Layer after the Application of Static Load and Moving Load to a Non-Exposed Type Waterproofing Layer (비노출 방수층에 작용하는 정하중과 동하중 작용 후의 방수층 물성변화에 관한 연구)

  • Seon, Yun-Suk;Kim, Jin-Seong;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2007.04a
    • /
    • pp.141-145
    • /
    • 2007
  • The part in the structure that is most affected by changes of external temperature is the protective concrete layer that protects a waterproofing layer. Also, the waterproofing layer that is situated under or on the back of such a protective concrete layer is affected by temperature and the behavior of the protective concrete layer under the condition of consolidation or close adhesion. In particular, in many cases, the damage is serious mainly around the projection (such as a parapet), crack, and joint (expansion joint). However, there is no proper way of examining again the non-exposed waterproofing layer once it has been constructed. Therefore, there is an assessment only on the physical property of materials and the capability of the layer in construction, and there is no actual assessment in consideration of its environmental condition or the condition of the use of buildings after construction. Therefore, in order to create more pleasant buildings and to enhance the durability of structures, this study conducts research into the change of capability of non-exposed waterproofing material after the application of a static load and moving load on the waterproofing layer situated under or on the back of protective concrete.

  • PDF

The Reaction Characteristics of NOx/N2O and NH3 in Crematory Facility SCR Process with Load Variation (부하변동이 큰 화장시설 SCR 공정에서 NOx/N2O 및 NH3 동시 저감 특성 연구)

  • Park, Poong Mo;Lee, Ha Young;Yeo, Sang-Gu;Yoon, Jae-Rang;Dong, Jong In
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.33 no.6
    • /
    • pp.605-615
    • /
    • 2017
  • Efficient simultaneous reduction conditions for $NO_x$ and $NH_3$-slip was investigated in SCR (Selective Catalytic Reduction) process with load variation by applying dual catalysts (SCR catalyst, $NH_3$ decomposition catalyst) system. $N_2O$ formation characteristics were analyzed to look into possible undesirable reaction pathways. In the experiments of catalyst characteristics, various operational variables were tested for the combined catalytic system, such as $NH_3/NO_x$ ratio, temperature, oxygen concentration and $H_2O$. The reaction characteristics of $NO_x$, $NH_3$ and $N_2O$ were analyzed and optimal conditions could be evaluated for the combustion facility with varied load. In terms of $NO_x/NH_3$ simultaneous reduction and $N_2O$ formation suppression, optimal condition was considered NSR 1.2 and temperature $300^{\circ}C$. At this operational condition, $NO_x$ conversion was 98%, $NH_3$ reduction efficiency was 95%, generated $N_2O$ concentration 9.5 ppm with inlet $NO_x$ concentration of 100 ppm. In $NH_3-SCR$ process with $NH_3$ decomposition catalyst, $NO_x$ and $NH_3$ can be considered to be reduced simultaneously at limited conditions. The results of this study may be utilized as basic data at facilities requiring simultaneous $NO_x$ and $NH_3$ reduction for facilities with load variation.

A Study on the Accelerated Life Evaluation of Drive Shaft for Independent Suspension type AWD Vehicle (독립현가형 AWD 차량의 구동축 가속 수명 평가에 관한 연구)

  • Kim, Do-Sik
    • Journal of Applied Reliability
    • /
    • v.11 no.4
    • /
    • pp.343-356
    • /
    • 2011
  • This paper proposes an accelerated life evaluation of drive shaft. The life test of drive shaft for independent suspension type AWD vehicle should be performed by use of the least test sample because many number of samples can't be used for the test because of its mass capacity and high price. We calculated the no failure test time by application of no failure test concept, and the already performed test data for drive shaft are applied for some kinds of reliability coefficients which are needed for calculation of life test time. And, for analysis of real driving condition of vehicle, the load spectrum is prepared using the needed road condition and vehicle data. The inverse power model is used for accelerated life test. The equivalent torque of load spectrum is achieved by use of Miner's Rule, and then the final accelerating condition is determined by decision of the accelerated test torque. This paper shows that the accelerated life test results corresponds with the target life and the proposed life test method can be very well applied to no failure life test for mass capacity machinery components.