Acknowledgement
Supported by : National Natural Science Foundation of China
References
- Bai, F.L., Hao, H., Bi, K.M. and Li, H.N. (2011), "Seismic response analysis of transmission tower-line system on a heterogeneous site to multi-component spatial ground motions", Adv. Struct. Eng., 286(3), 565-585.
- GB 18306-2015 (2015), Seismic Ground Motion Parameters Zonation Map of China, Standardization Administration of China Press, Beijing, China.
- GB 50260-2013 (2013), Code for Seismic Design of Electrical Installations, China Architecture & Building Press, Beijing, China.
- Ghobarah, A. and Aziz, T.S. (1996), "El-Attar M. response of transmission lines to multiple support excitation", Eng. Struct., 18(12), 936-946. https://doi.org/10.1016/S0141-0296(96)00020-X
- Hall, J.F., Holmes, W.T. and Somers, P. (1996), "Northridge earthquake of January 17, 1994", Earthquake Engineering Research Institute, California, USA.
- Lei, Y.H. and Chien, Y.L. (2009), "Seismic analysis of transmission towers under various line configurations", Struct. Eng. Mech., 31(3), 241-264 https://doi.org/10.12989/sem.2009.31.3.241
- Li, H.N., Shi, W.L. and Jia, L.G. (2004), "Limitations of effects of lines on in-plane vibration of transmission towers and simplified seismic calculation method", J. Vib. Control., 23(2), 1-7.
- Li, H.N., Shi, W.L., Wang, G.X. and Jia, L.G. (2005), "Simplified models and experimental verification for coupled transmission tower-line system to seismic excitations", J. Sound. Vib., 286(3), 565-585.
- Lu, X.L., Chen, Y. and Mao, Y.J. (2012), "Shaking table model test and numerical analysis of a super tall building with high-level transfer storey", Struct. Des. Tall Spec. Build., 21(10), 699-723. https://doi.org/10.1002/tal.632
- NCREE (1999), Investigation Report of Chi-Chi Earthquake, National Center for Research on Earthquake Engineering, Taiwan.
- Park, H.S., Choi, B.H., Kim, J.J. and Lee, T.H. (2016), "Seismic performance evaluation of high voltage transmission towers in South Korea", KSCE J. Civil Eng., 20(6), 2499-2505. https://doi.org/10.1007/s12205-015-0723-3
- Sedov, L. (1959), Similarity and Dimensional Methods in Mechanics, CRC Press.
- Shinozuka, M. (1995), "The Hanshin-Awaji earthquake of January 17, 1995 Performance of life lines", Report NCEER-95-0015, NCEER.
- Tian, L., Gai, X. and Qu, B. (2017b), "Shake table tests of steel towers supporting extremely long-span electricity transmission lines under spatially correlated ground motions", Eng. Struct., 132, 791-807. https://doi.org/10.1016/j.engstruct.2016.11.068
- Tian, L., Gai, X., Qu, B., Li, H.N. and Zhang, P. (2016), "Influence of spatial variation of ground motions on dynamic responses of supporting towers of overhead electricity transmission systems: an experimental study", Eng. Struct., 128, 67-81. https://doi.org/10.1016/j.engstruct.2016.09.010
- Tian, L., Li, H.N. and Liu, G.H. (2012), "Seismic response of power transmission tower-line system under multi-component multi-support excitations", J. Earthq. Tsunami, 6(4), 1250025-1-21. https://doi.org/10.1142/S179343111250025X
- Tian, L., Ma, R.S., Li, H.N. and Zhang, P. (2014), "Seismic Response of straight line type and broken line type transmission lines subjected to non-uniform seismic excitations", Adv. Steel. Constr., 10(1), 85-98.
- Tian, L., Niu, Y.H., Ma, R.S., Li, X.J., Yi, S.Y., Xin, A.Q. and Guo, W. (2017c), "Design study on shaking table test model of a long span transmission tower-line system coupling system", World Earthq. Eng., 33(3), 42-50.
- Tian, L., Pan, H.Y., Ma, R.S. and Qiu C.X. (2017a), "Collapse simulations of a long span transmission tower-line system subjected to near-fault ground motions", Earthq. Struct., 13(2), 211-220. https://doi.org/10.12989/EAS.2017.13.2.211
- Wang, W.M., Li, H.N. and Tian, L. (2013), "Progressive collapse analysis of transmission tower-line system under earthquake", Adv. Steel. Constr., 9(2), 161-174.
- Zhang, M.Z. (1997), "Study on similitude laws for shaking table tests", Earthq. Eng. Eng. Vib., 17(2), 52-58.
- Zhou, Y. and Lu, X.L. (2012), Method and Technology for Shaking Table Model Test of Building Structures, Science Press, Beijing, China.
Cited by
- Seismic and collapse analysis of a UHV transmission tower-line system under cross-fault ground motions vol.19, pp.6, 2020, https://doi.org/10.12989/eas.2020.19.6.457