DOI QR코드

DOI QR Code

A Study on Effect of the Image Applying to Breast Implants in Breast Specific Gamma Imaging

유방전용감마카메라에서 유방 보형물이 영상에 미치는 영향에 관한 고찰

  • Lee, Juyoung (Department of Radiological Technology, Songho College) ;
  • Lee, Tae Soo (Department of Biomedical Engineering Graduate School, Chungbuk National University) ;
  • Park, Hoon-Hee (Department of Radiological Technology, Shingu College)
  • 이주영 (송호대학교 방사선과) ;
  • 이태수 (충북대학교 대학원 의용생체공학과) ;
  • 박훈희 (신구대학교 방사선과)
  • Received : 2017.09.18
  • Accepted : 2018.02.12
  • Published : 2018.02.28

Abstract

There are limits to check the lesion as inserting a breast implant patients. So the application of BSGI based on Nuclear Medicine examination has increased. In this study, therefore we confirmed the effect of the image applying to breast implants in Breast Specific Gamma Imaging. We utilized Dilon 6800 BSGI scanner and developed the phantom. The self-development phantom was a rectangular shape of $230{\times}190{\times}80mm$ size and had 5 spheres which consisted of diameters of 10, 13, 17, 22, 28 mm in central part. We injected $^{99m}TcO_4$ into the self-development phantom in the proportion of four to one and made each additional phantom filled with 0.9 % sodium chloride, silicon and paraffin. Each additional phantom was placed between detector and self-development phantom. Each image was acquired five times depending on the type and thickness of the additional phantom. Statistical analysis with SPSS ver.18 was applied. In the test of variation according to the thickness of all additional phantoms, as the phantoms which 0.9% sodium chloride, silicon and paraffin increased, the attenuation variation was higher(P<0.005). There was no significant difference in the attenuation variation and the quality of image for type of the additional phantom. Therefore, if the effect of the image applying to breast implants in Breast Specific Gamma Imaging is confirmed, the higher diagnostic value can be achieved.

Keywords

References

  1. Claire E, Stephanie W, Anita P, et. al. "Breast-Specific Gamma Imaging Influences SurgicalManagement in Patients with Breast Cancer", Breast J., Vol. 19, No. 5, pp. 512-519, 2013. https://doi.org/10.1111/tbj.12147
  2. Stanley J. G, Ward P, Milton J. G, et. al., "SNM Practice Guideline for Breast Scintigraphy with Breast-Specific g-Cameras 1.0.", J Nucl Med., Vol. 38, No. 4, pp. 219-224, 2010. https://doi.org/10.2967/jnmt.110.082271
  3. John W, Jocelyn A. R, Kristen G, et. al., "Quantification of Radio-tracer Uptake in Axillary Lymph Nodes using Breast Specific Gamma Imaging(BSGI): Benign Radio-tracer Extravasation versus Uptake Secondary to Breast Cancer", Breast J., Vol. 15, No. 6, pp. 579-582, 2009. https://doi.org/10.1111/j.1524-4741.2009.00834.x
  4. Hui T, Lei J, Yusen G, et. al., "Visual and semi-quantitative analyses of dual-phase breast-specific gamma imaging with Tc-99m-sestamibi in detecting primary breast cancer", Ann Nucl Med., Vol. 28, No. 1, pp. 17-24, 2014. https://doi.org/10.1007/s12149-013-0776-7
  5. Kim B, Moon B, Cha E., "A comparative study of breast-specific gamma imaging with the conventional imaging modality in breast cancer patients with dense breasts", Ann Nucl Med., Vol. 26, No. 10, pp. 823-829, 2014. https://doi.org/10.1007/s12149-012-0649-5
  6. Yu S, Wei W, Hua-W. Y, et. al., "Clinical usefulness of breast-specific gamma imaging as an adjunct modality to mammography for diagnosis of breast cancer: a systemic review and meta-analysis", Eur J Nucl Med Mol Imaging., Vol. 40, pp. 450-463, 2013.
  7. Dennis D, Jules L, Leo R, et. al., "Contrast-noise-ratio (CNR) analysis and optimisation of breast-specific gamma imaging (BSGI) acquisition protocols", EJNMMI Research Vol. 21, No. 3, 2013.
  8. Lee A, Chang J, Lim W, et. al., "Effectiveness of breast-specific gamma imaging (BSGI) for breast cancer in Korea: a comparative study", Breast J., Vol. 18, No. 5, pp. 453-458, 2012. https://doi.org/10.1111/j.1524-4741.2012.01280.x
  9. Park J, Lee A, Jung K, et. al., "Diagnostic Performance of Breast-Specific Gamma Imaging (BSGI) for Breast Cancer: Usefulness of Dual-Phase Imaging with 99mTc-sestamibi", Nucl Med Mol Imaging., Vol. 47, pp. 18-26, 2013. https://doi.org/10.1007/s13139-012-0176-2
  10. Francesco G, Naomi A, John N. A, et. al., "The EANM and SNMMI practice guideline for lymphoscintigraphy and sentinel node localization in breast cancer", Eur J Nucl Med Mol Imaging., Vol. 40, pp. 1932-1947, 2013.
  11. Orazio S., "The importance of standardized interpretation of molecular breast imaging with dedicated gamma cameras", Eur J Nucl Med Mol Imaging., Vol. 39, pp. 967-970, 2012. https://doi.org/10.1007/s00259-012-2095-y