DOI QR코드

DOI QR Code

Maximum TE Setting Range for Quantitatively Evaluating T2 Relaxation Time : Phantom Study

T2 이완시간의 정량적 평가에 있어서 Maximum TE의 설정 범위에 대한 연구 : 팬텀연구

  • Park, Jin Seo (Department of Radiological Science, Konkuk University Medical Center) ;
  • Kim, Seong-Ho (Department of Radiological Science, Konkuk University Medical Center)
  • 박진서 (건국대학교병원 영상의학과) ;
  • 김성호 (건국대학교병원 영상의학과)
  • Received : 2017.10.16
  • Accepted : 2017.12.14
  • Published : 2018.02.28

Abstract

This study aimed to evaluate the range of maximum TE that could measure T2 relaxation time accurately by setting diverse maximum TE with using contrast medium phantoms. Contrast medium phantoms ranging from low to high concentrations were made by using Gadoteridol. The relaxation time and relaxation rate were compared and evaluated by conducting T2 mapping by using reference data based on various TEs and data obtained from different maximum TEs. It was found that accurate T2 relaxation time could be expressed only when the maximum TE over a certain range was used in the section with long T2 relaxation time, such as the low concentration section of saline or gadolinium contrast medium. Therefore, the maximum TE shall be longer than the T2 relation time for accurately maturing the T2 relaxation of a certain tissue or a substance.

Keywords

References

  1. Wang W. C. Electromagnetic wave theory .New York, Wiley Online Library; 1986.
  2. Wangsness R. K. Electromagnetic fields. Electromagnetic Fields, 2nd, Wiley-VCH; 1986.
  3. Jones G. P. "pin-lattice relaxation in the rotating frame: weak-collision case. Physical Review. 1966.
  4. McRobbie D. W, Elizabeth A. M, and Martin J. G. MRI from Picture to Proton. Cambridge university press. 2017.
  5. Vymazal J, Hajek M, Patronas N, Giedd J. N, Bulte J. W, Baumgarner C, et al. The quantitative relation between T1-weighted and T2-weighted MRI of normal gray matter and iron concentration. Journal of magnetic resonance imaging. 1995;5(5):554-560. https://doi.org/10.1002/jmri.1880050514
  6. Stanisz G. J, Odrobina E. E, Pun J, Escaravage M, Graham S. J, Bronskill M. J, et al. T1, T2 relaxation and magnetization transfer in tissue at 3T, Magnetic resonance in medicine. 2005;54(3):507-512. https://doi.org/10.1002/mrm.20605
  7. Ferreira V. M, Piechnik S. K, Dall'Armellina E, Karamitsos T. D, Francis J. M, Choudhury R. P, et al. Non-contrast T1-mapping detects acute myocardial edema with high diagnostic accuracy: a comparison to T2-weighted cardiovascular magnetic resonance, Journal of cardiovascular magnetic resonance. 2012; 14(1):42.
  8. Crawley, Adrian P. and R. Mark Henkelman. A comparison of one-shot and recovery methods in T1 imaging, Magnetic resonance in medicine. 1988;7(1): 23-34. https://doi.org/10.1002/mrm.1910070104
  9. Drain L. E. A Direct Method of Measuring nuclear spin-lattice relaxation times, Proceedings of the Physical Society. Section A. 1949;62(5):301-306. https://doi.org/10.1088/0370-1298/62/5/306
  10. Hahn E. L. An accurate nuclear magnetic resonance method for measuring spin-lattice relaxation times, Physical Review. 1949;76(1):145. https://doi.org/10.1103/PhysRev.76.145
  11. Tofts P. S, Du Boulay E. P. G. H. Towards quantitative measurements of relaxation times and other parameters in the brain, Neuroradiology. 1990;32(5):407-415. https://doi.org/10.1007/BF00588474
  12. Tofts P. S. Methods for quantitative relaxation parameter mapping: measuring T1 and T2, Proc Int Soc Magn Reson Med. 2009:1-6.
  13. Jeong H.K, Kim S. H, Kang C. H, Lee S. H, Kim M. K, Lee Y, et al. Signal Change of Iodinated Contrast Agents in MR Imaging, Journal of the Institute of Electronics and Information Engineers. 2016;53(12):131-138. https://doi.org/10.5573/ieie.2016.53.12.131
  14. Prasad N. G. N, Rao, J. N. The estimation of the mean squared error of small-area estimators, Journal of the American statistical association. 1990;85(409):163-171. https://doi.org/10.1080/01621459.1990.10475320
  15. Levinson N. The Wiener (root mean square) error criterion in filter design and prediction, Studies in Applied Mathematics. 1946;25(1-4):261-278.
  16. ManjMn J. V , Carbonel l -Cabal l ero, Lul l J. J, GarcMa-MartM G, MartM-BonmatM L, Robles M. MRI denoising using non-local means, Medical image analysis. 2008;12(4):514-523. https://doi.org/10.1016/j.media.2008.02.004
  17. Haacke E. M, Brow, R. W, Thompson M. R, Venkatesan R. Magnetic resonance imaging, physical principles and sequence design. New York, Wiley-Liss. 1999.
  18. Langlois S, Desvignes M, Constans J. M, Revenu M. MRI geometric distorsion: A simple approach to correcting the effects of non-linear gradient fields, Journal of magnetic resonance imaging. 1999;9: 821-831. https://doi.org/10.1002/(SICI)1522-2586(199906)9:6<821::AID-JMRI9>3.0.CO;2-2