A Study of Measuring Vibration for Reproducing Waterhammer of Plant Equipment

플랜트 기자재 수충격 진동재현을 위한 진동측정에 관한 연구

  • OH, Jung-Soo (Division of Machinery Testing Center, korea Testing Certification) ;
  • Cho, Sueng-Hyun (Division of Machinery Testing Center, korea Testing Certification)
  • 오정수 (한국기계전기전자시험연구원 기계금속센터) ;
  • 조승현 (한국기계전기전자시험연구원 기계금속센터)
  • Received : 2017.10.19
  • Accepted : 2017.11.03
  • Published : 2017.11.30

Abstract

In this study, among the various types of plant equipment, valves, which are susceptible to water hammer, were selected as the diagnosis target. In order to effectively measure the vibration, an accelerometer was adapted for use in this difficult environment. The results showed that the maximum peak-to-peak vibration displacement caused by the action of water hammer on the valve was 21.40 mm, which would affect the structural stability of the valve and pipe. Meanwhile, the measured data was applied to the HIL simulator to verify the reproduction of the vibration. In the future, field data will be applied to the HIL simulator for the purpose of assessing the fatigue, durability and expected residual life of the plant equipment.

본 연구에서는플랜트 기자재 중 수충격에 취약한 밸브를 대상으로 수충격에 의한 진단결과를 나타내었다. 수충격에 의한 진동 상태를 살펴보기 위하여 진단환경 등을 고려하여 진동측정 센서로 가속도계를 선정했다. 플랜트 기자재의 작동환경을 진단하기 위해 실제 플랜트 송배수 라인의 밸브를 대상으로 수충격 발생 시 발생된 진동데이터를 취득했으며 현장데이터 분석결과 최대 진동변위 P-P 값은 21.40 mm로 나타나 수충격에 인한 밸브 자체 및 파이프 연결구조 및 지지대 안정성에 적지 않은 영향을 미칠 것이라 파악되었다. 또한 현장데이터를 중 일부 데이터를 HIL 시뮬레이터의 작동 데이터로 적용 비교함으로써 수 mm 레벨의 현장데이터의 진동재현성을 확인할 수 있었다. 한편, 이번 진단사례를 통해 향후 높은 수준의 진동 측정을 위해서는 충격 측정범위가 높은 센서의 도입이 필요할 것으로 사료되며 보다 정확한 진동재현을 위해 플랜트 기자재의 구속조건 등을 분석하여 다축 피로 내구 안정성 시험과 가속 수명예측 등에 활용할 예정이다.

Keywords

References

  1. C. H. Park, W. S. Yoon, K. S. Chang," A Study on the Development of Experiment Method for ACC Using Powertrain HILS", The Korean Society of Automotive Engineers, vol. 7, no. 6, pp. 165-173, 1999.
  2. Y. C. Bae, Y. S. Lee and Y. H. Kim, "Countermeasure on High Vibration of Branch Pipe with Pressure Pulsation Transmitted from Main Steam Header, Transactions", The Korean Society for Noise and Vibration Engineering", vol. 15, no. 8, pp. 988-995, 2005. DOI: https://doi.org/10.5050/KSNVN.2005.15.8.988
  3. Y. H. Kim, "Examination on High Vibration and Branch Vent Pipe's Failure of Complex Piping System Suppling Condensate-water in Power Site", The Korean Society for Noise and Vibration Engineering, Annual Autumn Conference, pp. 380-384, 2010.
  4. J. S. Suh, "A Study on the Measurement of the Pipeline Displacement Using Accelrometers", The Korean Society for Noise and Vibration Engineering, vol. 24, no. 6, pp. 476-482, 2016. DOI: https://doi.org/10.5050/KSNVE.2014.24.6.476
  5. Y. S. Choi, K. M. Jeong, "Study on the Correction of Laser Range Fider Measurement Error", Korea Society for Precision Engineering, Annual Spring Conference, pp. 433-434, 2011.
  6. Hewlett Packard Co., "Laser Measurement System User's Guide, Manual Part no. 00528-90010," 1984.