DOI QR코드

DOI QR Code

Radiometric Calibration Method with Compensation of Nonlinearity of Detector for Hyper-Spectral Camera

  • 투고 : 2017.08.28
  • 심사 : 2017.09.22
  • 발행 : 2017.10.31

초록

In this paper, we propose a novel radiometric calibration method which can effectively compensate the nonlinearity of the detector for hyper-spectral camera. In general, the detector of hyper-spectral camera can produce nonlinear output depending on radiance and integral time. The conventional radiometric calibration methods extract the imprecise radiance profile from the spectral profile of the target due to this nonlinearity. In our proposed method, we use a quadratic equation instead of a linear equation to describe the relation between output of detector and radiance. Then, we use a fractional function to compensate variation of integration time. Thus, our proposed method can extract more precise spectral profile of radiance than conventional radiometric calibration method.

키워드

참고문헌

  1. Hong, Suk-Min, "Image Acquisition and Analysis by Hyper Spectral Sensor," The Korea Institute of Military Science and Technology, Annual Conference Journal Vol. 2, pp. 591-594, Sep. 2002.
  2. Kim, Sun-Hwa; Lee, Kyu-Sung; Ma, Jung-Lim; Kuk, Min-Jung, "Current Status of Hyperspectral Remote Sensing: Principle, Data Processing Techniques, and Applications," Korea journal of Remote Sensing, Vol. 21 No. 4, pp. 341-369, Aug. 2005. https://doi.org/10.7780/kjrs.2005.21.4.341
  3. Jeong, Jun-Ho; Kim, Jae-Hyup, "Measure Radiation and Correct Radiation in IR camera Image," Journal of the Korea Society of Computer and Information, Vol. 20, No. 4, pp. 57-67, Mar. 2015. https://doi.org/10.9708/jksci.2015.20.4.057
  4. Kim, Yeon-Soo, "Military use of Hyper Spectral Technology," Optical science and technology, Vol. 16 No. 4, pp. 36-40, Oct. 2012.
  5. Chang, An-jin; Choi, Jae-wan; Song, Ah-ram; Kim, Ye-ji; Jung, Jin-ha, "Vicarious Radiometric Calibration of RapidEye Satellite Image Using CASI Hyperspectral Data," Journal of Korean Society for Geospatial Information System, Vol. 23, No. 3, pp. 3-10, Sep. 2015. https://doi.org/10.7319/KOGSIS.2015.23.3.003
  6. Choe Se-woon; Woo, Young-woon, "Application of Hyperspectral Imaging System to Analyze Vascular Alteration for Preclinical Models," Journal of the Korea Society of Computer and Information, Vol. 20, No. 4, pp. 69-76, Mar. 2015. https://doi.org/10.9708/jksci.2015.20.4.069
  7. Yang, Jeong-Kyu; Park, Hee-Duk, "Real Time Relative Radiometric Calibration Processing of Short Wave Infra-Red Sensor for Hyper Spectral Imager," Journal of The Korea Society of Computer and Information, 21(11), pp1-7, 2016. https://doi.org/10.9708/JKSCI.2016.21.11.001
  8. Shin, Jung-Il; Yasser Maghsoudi; Kim, Sun-Hwa; Kang, Sung-Jin; Lee, Kyu-Sung, "Vicarious Radiometric Calibration of the Ground-based Hyperspectral Camera Image," Korean Journal of Remote Sensing, Vol. 24, No. 2, pp. 213-222, Apr. 2008. https://doi.org/10.7780/kjrs.2008.24.2.213
  9. Michael T Eismann, "Hyperspectral remote sensing," SPIE press, Bellingham, 725 page, 2012.
  10. Zadnik, J.; Guerin, D.; Moss, R.; Orbeta, A.; Dixon, R.; Simi, C. G.; Dunbar, S. and Hill, S., "Calibration procedures and measurements for the COMPASS hyperspectral imager," Proc. SPIE Vol. 5425, pp. 182-188, Aug. 2004.
  11. Green, R. O.; Eastwood, M. L.; Sarture, C. M.; Chrien, T. G.; Aronsson, M.; Chippendale, B. J.; Faust, J. A.; Pavri, B. E.; Chovit, C. J.; Solis, M.; Olah, M. R. and Williams, O., "Imaging Spectroscopy and the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS)," Remote Sensing of Environment, Vol. 65, pp. 227-248, Sep. 1998. https://doi.org/10.1016/S0034-4257(98)00064-9
  12. Thomas G. Chrien; Robert O. Green; Michael L. Eastwood, "Accuracy of the spectral and radiometric laboratory calibration of the Airborne Visible/Infrared Imaging Spectrometer," Proc. SPIE 1298, Imaging Spectroscopy of the Terrestrial Environment, Vol. 37, Sep. 1990.