DOI QR코드

DOI QR Code

복강내압 측정을 위한 초소형 카데터 시스템

Micro-cathter System for Measurement of Intra-abdominal Pressure

  • Seo, Ho-Young (Dept. of Medical & Biological Eng., Graduate School, Kyungpook National University) ;
  • Na, Sungdae (Dept. of Medical & Biological Eng., Graduate School, Kyungpook National University) ;
  • Kim, Myoung Nam (Dept. of Biomedical Eng., School of Medicine, Kyungpook National University)
  • 투고 : 2017.07.19
  • 심사 : 2017.07.27
  • 발행 : 2017.08.31

초록

Recently, interest that intra-abdominal pressure has been increased as change of pathophysiology to critical patients. The intra-abdominal pressure is measured by cystometry what can be available for non-inclusively. However, conventional methods have some problems such as low SNR, weakness of environment temperature, and unsuitable size of sensor. In this paper, a new subminiature pressure sensor module and sensing system are proposed using a sensor of semiconductor type and FPCB. The module is more stable, flexible, and smaller than the conventional catheter. The performance of the developed module is evaluated by various quantitative analysis indexes. The proposed sensor has the high sensitivity and suitable size for measurement of cystometry more than the conventional method. In order to prove efficiency between conventional and proposed method, proposed method compared for sensitivity, fixable, and size. The proposed method will be help measurement of intra-abdominal pressure of patients due to high accuracy and comfortableness.

키워드

참고문헌

  1. E.J. Kimball, M.C. Mone, T.R. Wolfe, G.K. Baraghoshi, and S.C. Alder, "Reproducibility of Bladder Pressure Measurements in Critically Ill Patients," Intensive Care Medicine, Vol. 33, No. 7, pp. 1195-1198, 2007. https://doi.org/10.1007/s00134-007-0641-z
  2. S.J. Kim, J.S. Seo, M.H. Son, S.Y. Kim, K.H. Jung, E.H. Kang, et al., “The Effects of Intra-Abdominal Hypertension on the Prognosis of Critically Ill Patients in the Intensive Care Unit,” Tuberculosis and Respiratory Diseases, Vol. 61, No. 1, pp. 46-53, 2006. https://doi.org/10.4046/trd.2006.61.1.46
  3. P.K. Suominen, M.P. Pakarinen, P. Rautiainen, I. Mattila, and H. Sairanen, “Comparison of Direct and Intravesical Measurement of Intraabdominal Pressure in Children,” Journal of Pediatric Surgery, Vol. 41, No. 8, pp. 1381-1385, 2006. https://doi.org/10.1016/j.jpedsurg.2006.04.030
  4. Bulges Like a Lump in the Groin I Have Hernia?, http://www.kookje.co.kr (accessed Sep., 25, 2016).
  5. T.T. Levins, “Under Pressure: Rapid Identification and Treatment of Intra-abdominal Hypertension and Abdominal Compartment Syndrome May Save Lives,” Nursing in Critical Care, Vol. 2, No. 5, pp. 42-48, 2007. https://doi.org/10.1097/01.CCN.0000288846.69863.25
  6. B.K. Choi, H.Y. Lee, and J.H. Eom, Portable Bladder Pressure Monitoring Device, Patent No. 1014310510000, 2014.
  7. S.J. Kim, D.S. Lee, J.H. Kim, H.Y. Lee, B. Choi, S.W. Kim, et al., "Preliminary Report about the Efficacy of Prototype Pressure Sensor for the Real-Time Intravesical Pressure Monitoring in the Rabbit," The World Journal of Men's Health, Vol. 30, No. 1, pp. 80-86, 2012.
  8. J.L. Lee, Application of Sensor, Se-hwa publisher, GyeongGi-Do, 2001.