LH has been using ultra high strength reinforcing bars (SD500 and SD600), since 2011. Such a change requires an adjustment of the old extra rates of bar splice to reflect use of ultra high strength reinforcing bars, as these rates had been set based on SD400 bars. It is particularly difficult to calculate precisely rebar lap-splice locations for large areas, such as those in apartment buildings. This research aims to adjust the extra rates of bar splice to reflect a reasonable rate; the rebar lap-splice length is not an exact estimation, but instead, an extra rates of bar splice is set and the rebar lap-splice length is increased by 2% (D 10) - 7% (025) depending on the bar size. The subjects of this study are LH apartments undergoing frame construction. We studied the quantity estimations from the design drawings, and analyzed the settlement quantities of construction field. The results of the study revealed that, when each of the quantities are analyzed, consider adjusting the extra rates of bar splice of some rebar to 1% - 3.5%. This was caused by an overuse of reinforcing bars in onsite construction and the use of supporting bars that have not been reflected in the documents, among other reasons. Based on the results of our study, an improvement plan for the current extra rates of bar splice seems to be necessary, cutting or raising the rate depending on the analysis of the data. Through this study, we expect to contribute to the calculation of reasonable construction costs, improvements in the quality of rebar work, and improvements in the capacity of design techniques for apartment buildings.

Keywords

References

  1. 대한건축학회(2013, 2006), 건축공사 표준시방서
  2. 대한건축학회(2009), 건축구조설계기준(KBC 2009)
  3. 한국토지주택공사(2014), 공사원가산정지침
  4. 한국콘크리트학회(2005), 최신콘크리트공학
  5. 한국콘크리트학회(2012), 콘크리트구조설계기준
  6. 한국콘크리트학회(2013), 콘크리트 표준시방서
  7. ACI(2014), ACI 318-14 Building Code and Commentary
  8. CEB/FIP(1990), Model Code 1990, Chap 4. Concrete Structures
  9. 건축도시연구정보센터 홈페이지 http://www.auric.or.kr/
  10. 대한건축학회 홈페이지 http://www.aik.or.kr/
  11. 토목연구정보센터 홈페이지 http://www.ceric.net/
  12. 한국건축시공학회 홈페이지 http://www.kic.or.kr/
  13. 한국콘크리트학회 홈페이지 http://www.kci.or.kr/