• Title/Summary/Keyword: 이음조정률

Search Result 2, Processing Time 0.017 seconds

Comparison of the quantity estimations from the design phase and the settlement quantities of construction field to improve the extra rates of bar splice (철근 이음조정률의 개선을 위한 설계견적 수량과 현장시공 정산 수량의 비교분석 연구)

  • Kim, Sang-Yeon;Choi, Bo-Mi
    • Land and Housing Review
    • /
    • v.8 no.4
    • /
    • pp.257-266
    • /
    • 2017
  • LH has been using ultra high strength reinforcing bars (SD500 and SD600), since 2011. Such a change requires an adjustment of the old extra rates of bar splice to reflect use of ultra high strength reinforcing bars, as these rates had been set based on SD400 bars. It is particularly difficult to calculate precisely rebar lap-splice locations for large areas, such as those in apartment buildings. This research aims to adjust the extra rates of bar splice to reflect a reasonable rate; the rebar lap-splice length is not an exact estimation, but instead, an extra rates of bar splice is set and the rebar lap-splice length is increased by 2% (D 10) - 7% (025) depending on the bar size. The subjects of this study are LH apartments undergoing frame construction. We studied the quantity estimations from the design drawings, and analyzed the settlement quantities of construction field. The results of the study revealed that, when each of the quantities are analyzed, consider adjusting the extra rates of bar splice of some rebar to 1% - 3.5%. This was caused by an overuse of reinforcing bars in onsite construction and the use of supporting bars that have not been reflected in the documents, among other reasons. Based on the results of our study, an improvement plan for the current extra rates of bar splice seems to be necessary, cutting or raising the rate depending on the analysis of the data. Through this study, we expect to contribute to the calculation of reasonable construction costs, improvements in the quality of rebar work, and improvements in the capacity of design techniques for apartment buildings.

수배전 시스템의 에너지 절약$\cdot$이용합리화 3. 액티브 콘덴서

  • 대한전기협회
    • JOURNAL OF ELECTRICAL WORLD
    • /
    • s.264
    • /
    • pp.84-89
    • /
    • 1998
  • 지금까지 수전설비의 역률조정에는 진상콘덴서가 사용되었고 콘덴서뱅크의 투입-해별에 따라 Step 모양으로 제어하여, 역률 개선효과는 0.98$\~$0.97정도가 일반적이었다.그러나 자에너지(에너지 절약$\cdot$이용합리화)에 대한 관심이 높아지는 가운데, 부하기기에 대해서는 파워일렉트로닉스 기술을 이용한 인버터화 등에 의하여 자에너지화가 도모되고 있다. 또한 코제너레이션의 설치에 의한 설비 전체로서의 에너지의 유효활동도 이루어져, 역률조정에서도 변동이 적고 가능한 한 고역률을 유지할 것을 요망하고 있다. 또 자에너지화에 크게 기여하고 있는 인버터 등에서 발생하는 전기공해라고도 할 수 있는 고조파전류가 많이 발생하고, 이 고조파전류의 유입으로 진상콘덴서의 과열$\cdot$이음발생 등의 이상을 일으키는 경우가 최근에 많이 발생하고 있다. 이와 같은 배경에서 액티브필터 제어기술을 적용하여 전력용콘덴서를 사용하지 않는 무효전력보상장치인 액티브 콘덴서(active condenser)를 제품화하여 시장에 내놓았다. 액티브 콘덴서는-무효전류 연속제어에 의하여 전원역률을 1.0으로 유지 -고속응답성 -대용량 IGBT(Insulted Gate Bipolar transistor)소자의 채용에 의한 소형화 -고조파의 영향을 받지 않음 등 지금까지의 진상콘덴서에는 없는 우수한 장점이 있어, 자에너지와 고조파문제에 유효한 수단이 되고 있다.

  • PDF