Abstract
Residual stress is defined as stress that already exists on a structural member from the effects of welding and plastic deformation before the application of loading. Due to such residual stress, welded H-section compression members under centroidal compression load can undergo buckling and failure for strength values smaller than the predicted buckling load and specified compressive strength. Therefore, this study was carried out to evaluate the effect of residual stress from welding on the determination of the buckling load and specified compressive strength of the H-section compression member according to the column length variation. A three-dimensional nonlinear finite element analysis was performed for the H-section compression member where the welded joint was fillet welded by applying heat inputs of 3.1kJ/mm and 3.6kJ/mm using the SAW welding method.
확장단부판 접합부는 강구조물의 보-기둥 접합부 혹은 변단면 부재로 구성된 PEB 구조시스템에 적용되는 접합부의 한 형태이다. 확장단부판 접합부는 접합부를 구성하는 단부판의 두께, 고장력볼트의 게이지 거리, 고장력볼트 축부의 직경, 고장력볼트의 개수 등의 영향으로 상이한 거동특성을 나타낸다. 확장단부판 접합부는 미국 및 유럽 등지에서는 다양한 형태로 강구조물의 기둥-보 접합부에 적용되고 있으나 우리나라에서는 널리 적용되고 있지 않다. 이러한 이유로는 확장단부판 접합부에 대한 설계강도식 제안, 접합부상세 제안, 내진성능 평가, 제작 및 시공지침서 개발 등이 적절히 이루어지지 못하고 있기 때문이다. 따라서 이 연구는 비보강 확장단부판 접합부의 국내 적용을 위한 기초자료를 제공하기 위하여 진행하였다. 이를 위하여 두께 12mm의 비보강 확장단부판에 대한 비선형 유한요소해석 및 실험을 수행하였다.