References
- Hall JR. Blood contamination of anesthesia equipment and monitoring equipment. Anesth Analg 1994;78(6):1136-1139.
- Morell RC, Ririe D, James RL, Crews DA, Huffstetler K. A survey of laryngoscope contamination at a university and a community hospital. Anesthesiology 1994;80(4):960. https://doi.org/10.1097/00000542-199404000-00038
- Lee SO. A survey on hospital infection. J Nurs Acad Soc 1993;23(3):325-338 (Korean). https://doi.org/10.4040/jnas.1993.23.3.325
- Kim JM. Current state of nosocomial infections in Korea. Korean J Med 1999;57(4):572-577 (Korean).
- Cullen MM, Trail A, Robinson M, Keaney M, Chadwick PR. Serratia marcescens outbreak in a neonatal intensive care unit prompting review of decontamination of laryngoscopes. J Hosp Infect 2005;59(1):68-70. https://doi.org/10.1016/j.jhin.2004.08.003
- Jones BL, Gorman LJ, Simpson J, Curran ET, McNamee S, Lucas C, et al. An outbreak of Serratia marcescens in two neonatal intensive care units. J Hosp Infect 2000;46(4):314-319. https://doi.org/10.1053/jhin.2000.0837
- Rutala WA, Weber DJ; Healthcare Infection Control Practices Advisory Committee (HICPAC). Guideline for disinfection and sterilization in healthcare facilities, 2008 [cited 2017 Apr 28]. Available from: https://www.cdc.gov/hai/pdfs/disinfection_nov_2008.pdf.
- Ministry of Government Legislation. Guidelines for medical instruments and material disinfection in healthcare facilities [cited 2014 Aug 13]. Available from: http://www.law.go.kr/admRulLsInfoP.do?admRulSeq=2000000014476 (Korean).
- AORN Recommended Practices Committee. Recommended practices for cleaning, handling and processing anesthesia equipment. AORN J 2005;81(4):856-857, 860-870. https://doi.org/10.1016/S0001-2092(06)60365-7
- Muscarella LF. Reassessment of the risk of healthcare-acquired infection during rigid laryngoscopy. J Hosp Infect 2008;68(2):101-107. https://doi.org/10.1016/j.jhin.2007.11.004
- Kim HY, Lee EJ, Jang EK, Park YA. A study for infection control standards for medical devices in NICU. J Korean Clin Nurs Res 2010;16(2):69-84 (Korean).
- Williams D, Dingley J, Jones C, Berry N. Contamination of laryngoscope handles. J Hosp Infect 2010;74(2):123-128. https://doi.org/10.1016/j.jhin.2009.09.015
- Negri de Sousa AC, Levy CE, Freitas MI. Laryngoscope blades and handles as sources of cross-infection: an integrative review. J Hosp Infect 2013;83(4):269-275. https://doi.org/10.1016/j.jhin.2012.10.015
- Esler MD, Baines LC, Wilkinson DJ, Langford RM. Decontamination of laryngoscopes: a survey of national practice. Anaesthesia 1999;54(6):587-592. https://doi.org/10.1046/j.1365-2044.1999.00755.x
- Simmons SA. Laryngoscope handles: a potential for infection. AANA J 2000;68(3):233-236.
- Lowman W, Venter L, Scribante J. Bacterial contamination of re-usable laryngoscope blades during the course of daily anaesthetic practice. S Afr Med J 2013;103(6):386-389. https://doi.org/10.7196/SAMJ.6385
- Call TR, Auerbach FJ, Riddell SW, Kiska DL, Thongrod SC, Tham SW, et al. Nosocomial contamination of laryngoscope handles: challenging current guidelines. Anesth Analg 2009;109(2):479-483. https://doi.org/10.1213/ane.0b013e3181ac1080
- EBIOX. Trionic: advanced environmental hygiene [cited 2014 Mar 2]. Available from: http://www.ebiox.co.uk/products/view/trionic/.
- Qureshi T, Barbut F, Pernet P, Neyme D, Maury E, Offenstadt G. Laryngoscope handles in a medical intensive care unit: the level of bacterial and occult blood contamination. J Hosp Infect 2008;68(1):94-95. https://doi.org/10.1016/j.jhin.2007.10.014
- Telang R, Patil V, Ranganathan P, Kelkar R. Decontamination of laryngoscope blades: is our practice adequate? J Postgrad Med 2010;56(4):257-261. https://doi.org/10.4103/0022-3859.70930
- Howell V, Thoppil A, Young H, Sharma S, Blunt M, Young P. Chlorhexidine to maintain cleanliness of laryngoscope handles: an audit and laboratory study. Eur J Anaesthesiol 2013;30(5):216-221. https://doi.org/10.1097/EJA.0b013e3283607827
- Hwang SH, Park DU, Ha KC, Cho HW, Yoon CS. Airborne bacteria concentrations and related factors at university laboratories, hospital diagnostic laboratories and a biowaste site. J Clin Pathol 2011;64(3):261-264. https://doi.org/10.1136/jcp.2010.084764
- Machan MD, Monaghan WP, McDonough J, Hogan G. Emerging evidence in infection control: effecting change regarding use of disposable laryngoscope blades. AANA J 2013;81(2):103-108.
- Anderson K, Gambhir S, Glavin R, Kinsella J. The use of an anaesthetic simulator to assess single-use laryngoscopy equipment. Int J Qual Health Care 2006;18(1):17-22. https://doi.org/10.1093/intqhc/mzi091
Cited by
- Contamination and Disinfection of Rigid Laryngoscopes: A Literature Review vol.110, pp.1, 2017, https://doi.org/10.1002/aorn.12724
- A cost comparison between reusable flexible and disposable laryngoscopes vol.43, pp.2, 2022, https://doi.org/10.1016/j.amjoto.2021.103321