DOI QR코드

DOI QR Code

Zirconia ceramic fixed dental prosthesis with all-on-4 concept implants for irradiated maxilla: A case report

방사선 조사된 상악골에서 all-on-4 임플란트에 의해 지지되는 지르코니아 고정성 보철물 수복 증례

  • Choi, Eun-Joo (Department of Oral and Maxillofacial Surgery, College of Dentistry, Wonkwang University) ;
  • Cho, Hye-Won (Department of Prosthodontics, College of Dentistry, Wonkwang University)
  • 최은주 (원광대학교 치과대학 구강악안면외과학교실) ;
  • 조혜원 (원광대학교 치과대학 치과보철학교실)
  • Received : 2016.12.13
  • Accepted : 2017.02.03
  • Published : 2017.04.28

Abstract

The implant-supported fixed dental prosthesis in irradiated maxilla needs meticulous treatment planning due to low bone healing capacity. All-on-4 concept implantation can reduce the number of implants to be placed avoiding bone grafting procedure. Conventionally, prefabricated angled abutments for tilted implants have been used. However, in this case, it was replaced with computer-aided design and computer-aided manufacturing (CAD/CAM) abutment. This case report described all-on-4 concept implantation and fabrication of CAD/CAM zirconia fixed dental prostheses using CAD/CAM titanium abutments.

방사선치료를 받은 상악에 임플란트 지지 고정성 보철물을 이용하여 수복하는 것은 골치유능력이 낮기 때문에 상세한 치료계획이 필요하다. All-on-4 개념에 의한 임플란트 식립은 골이식을 피하면서 임플란트를 매식할 수 있어 유리하다. 일반적으로 경사된 임플란트에는 기성 경사형 지대주를 사용해왔다. 본 임상증례에서는 computer-aided design and computer-aided manufacturing (CAD/CAM)으로 제작된 지대주를 사용하였다. 본 증례는 all-on-4 개념에 의해 임플란트를 매식하고 CAD/CAM titanium 지대주를 제작한 다음 CAD/CAM zirconia 고정성 보철물로 수복하여 좋은 결과를 얻었기에 보고하고자 한다.

Keywords

References

  1. Zarb G, Bolender C, Eckert S, Jacob R, Fenton A, Mericske-Stern R. Prosthodontic treatment for edentulous patients. 12th ed. St. Louis: Elsevier Mosby; 2004. p. 427.
  2. Beumer J III, Curtis TA, Marunick MT. Maxillofacial rehabilitation: prosthodontic and surgical considerations. St. Louis: Ishiyaku Euro America, Inc.; 1996. p. 65-70, 85.
  3. Malo'P, Nobre Md, Lopes A. The rehabilitation of completely edentulous maxillae with different degrees of resorption with four or more immediately loaded implants: a 5-year retrospective study and a new classification. Eur J Oral Implantol 2011;4:227-43.
  4. Malo'P, de Arau'jo Nobre M, Lopes A, Francischone C, Rigolizzo M. "All-on-4" immediate-function concept for completely edentulous maxillae: a clinical report on the medium (3 years) and longterm (5 years) outcomes. Clin Implant Dent Relat Res 2012;14:e139-50. https://doi.org/10.1111/j.1708-8208.2011.00395.x
  5. Malo'P, de Arau'jo Nobre MA, Lopes AV, Rodrigues R. Immediate loading short implants inserted on low bone quantity for the rehabilitation of the edentulous maxilla using an All-on-4 design. J Oral Rehabil 2015;42:615-23. https://doi.org/10.1111/joor.12291
  6. Barnea E, Tal H, Nissan J, Tarrasch R, Peleg M, Kolerman R. The Use of Tilted Implant for Posterior Atrophic Maxilla. Clin Implant Dent Relat Res 2016;18:788-800. https://doi.org/10.1111/cid.12342
  7. Kim KS, Kim YL, Bae JM, Cho HW. Biomechanical comparison of axial and tilted implants for mandibular full-arch fixed prostheses. Int J Oral Maxillofac Implants 2011;26:976-84.
  8. Abdulmajeed AA, Lim KG, Narhi TO, Cooper LF. Completearch implant-supported monolithic zirconia fixed dental prostheses: A systematic review. J Prosthet Dent 2016;115:672-7. https://doi.org/10.1016/j.prosdent.2015.08.025
  9. Papaspyridakos P, Lal K. Computer-assisted design/computerassisted manufacturing zirconia implant fixed complete prostheses: clinical results and technical complications up to 4 years of function. Clin Oral Implants Res 2013;24:659-65. https://doi.org/10.1111/j.1600-0501.2012.02447.x
  10. Rojas-Vizcaya F. Full zirconia fixed detachable implant-retained restorations manufactured from monolithic zirconia: clinical report after two years in service. J Prosthodont 2011;20:570-6. https://doi.org/10.1111/j.1532-849X.2011.00784.x
  11. Pozzi A, Holst S, Fabbri G, Tallarico M. Clinical reliability of CAD/CAM cross-arch zirconia bridges on immediately loaded implants placed with computer-assisted/template-guided surgery: a retrospective study with a follow-up between 3 and 5 years. Clin Implant Dent Relat Res 2015;17:e86-96. https://doi.org/10.1111/cid.12132
  12. Kern JS, Kern T, Wolfart S, Heussen N. A systematic review and meta-analysis of removable and fixed implant-supported prostheses in edentulous jaws: post-loading implant loss. Clin Oral Implants Res 2016;27:174-95.
  13. Tsuge T, Hagiwara Y. Influence of lateral-oblique cyclic loading on abutment screw loosening of internal and external hexagon implants. Dent Mater J 2009;28:373-81. https://doi.org/10.4012/dmj.28.373
  14. Roumanas E, Nishimura R, Beumer J, Moy P, Weinlander M, Lorant J. Craniofacial defects and osseointegrated implants: Six-year follow-up report on the success rates of craniofacial implants at UCLA. Int J Oral Maxillofac Implants 1994;9:579-85.
  15. Chang JS, Ji W, Choi CH, Kim S. Catastrophic failure of a monolithic zirconia prosthesis. J Prosthet Dent 2015;113:86-90. https://doi.org/10.1016/j.prosdent.2014.07.016
  16. Lee DH. CAD/CAM-fabricated template for locating implant abutment screws in cement-retained anatomic zirconia restorations. J Prosthet Dent 2015;114:343-5. https://doi.org/10.1016/j.prosdent.2015.04.007
  17. Heintze SD, Rousson V. Survival of zirconia- and metal-supported fixed dental prostheses: a systematic review. Int J Prosthodont 2010;23:493-502.