References
- Ministry of Land, Infrastructure and Transport, "The Evacuative and Fireproof Construction of Buildings", Minister Decree No:149 (2014).
- Ministry of Land, Infrastructure and Transport, "Standards for Accreditation and Management of Fire Resistant Construction", Notification No:2016-416(2016).
- Korea Institute of Civil Engineering and Building Technology, Certificate List of Fire Resistant Construction", http://g4b.go.kr/ (2016).
- Ministry of Land, Infrastructure and Transport, "Detail Instructions for Accreditation and Management of Fire Resistant Construction", Document No:8703 (2016).
- Korea Agency for Technology and Standards, "Method for Calculating Fire Protective Thickness of Structural Steel According to Section Factor", KS F 2848:2010 (2010).
- T. Lennon, D. B. Moore, Y. C. Wang and C. G. Bailey 'Designer' guide to EN 1991-1-2, 1992-1 -2, 1993-1-2 and 1994-1-2 : HandBook for the fire design of steel, composite and concrete structures to the Eurocodes, thomas telford ltd. London, UK (2010).
- Korea Institute of Civil Engineering and Building Technology, "Fire safety comprehensive research institute", http://www.kict.re.kr/ (2016).
- S. M. Jeon and J. J.Kim..'Experimental Study on Separate Evaluations of Fire Resistance of SFRM for Steel Beams and Columns' Journal of the Architectural Institute of Korea, Vol. 18, No. 9, pp. 125-132 (2002).
- S. H. Kim, C. Y. Ok and S. M. Choi, "Clarification of the Thermal Properties of Intumescent Paint and Suggestion of the Required Fire Protection Thickness for Steel and Composite columns", J. Korean Soc. Adv. Comp. Struc. Vol. 6, No. 1, pp. 21-29. 125-132(2015) https://doi.org/10.11004/kosacs.2015.6.1.021
- C. W. Jung, N. Y. Jee and I. K. Kwon, "Study on the Determination of Fire Protection Thickness based on Section Factor", Proceedings of 2003 Spring Annual Conference, Korean Institute of Building Construction, pp. 139-142 (2003).
- Chi-Yeol Ok, Jae-Jun Kim. "Study of the Standard Testing Specifications for a Nonloading Performance Evaluation of Coating Material-sprayed Circular Steel Structures." FIRE SCIENCE AND ENGINEERING, 30.3 (2016.6): 7-15. https://doi.org/10.7731/KIFSE.2016.30.3.007
- Korea Agency for Technology and Standards, "Methods of fire Resistance Test for Elements of Building Construction- General Requirements", KS F 2257-1:2014(2014).
- Korea Agency for Technology and Standards, "Methods of Fire Resistance Test for Elements of Building Construction- Specific Requirements for Columns", KS F2257-7:2014 (2014).
- I. K. Kwon, N. Y. Jee and H. Y. Kim, "Experimental Study on the Determination of Fire Protection Thickness through Section Factors of Structural Steels", Journal of the Architectural Institute of Korea, Vol. 18, No. 9, pp. 125-132 (2002).
- C. W. Jung, N. Y. Jee and I. K. Kwon, "Study on the Determination of Fire Protection Thickness based on Section Factor", Proceedings of 2003 Spring Annual Conference, Korean Institute of Building Construction, pp. 139-142 (2003).
- S. H. Lee, K. H. Kim, M. S. Lee, H. Y. Kim, H. D. Kim, T. H. Song, C. Y. Ok, B. K. Jin, et al., "Development of Fire Resistance Design Method in Building", KICT 2004- 376, Korea Institute of Civil Engineering and Building Technology (2004).