DOI QR코드

DOI QR Code

An Experimental Study on Block Shear Strength of Austenitic Stainless Steel (STS304) Fillet-welded Connection

오스테나이트계 스테인리스강(STS304) 필릿 용접접합부의 모재 블록전단강도에 관한 실험적 연구

  • Received : 2016.10.20
  • Accepted : 2016.12.22
  • Published : 2017.01.30

Abstract

Many studies on structural behaviors of stainless steel structural members have been performed thanks to their superior material properties such as ductility, fire resistance and corrosion resistance. Austenitic stainless steels (STS304) with nickel have been used the most in building structure among stainless steel groups. This paper focused on the block shear fracture behavior of base metal in fillet-welded connection fabricated with austenitic stainless steel. Although the block shear behavior for welded connection due to stress triaxiality and shear-lag effect is different from that of bolted connection, the block shear strength equation of welded connection in current design specifications has been referred to that of bolted connection. Main parameters are weld length and welding method (Arc and TIG welding). It is known from test results that there was no big difference in ultimate strengths according to welding method. Predictions by current specifications (KBC, AISC and EC) and existing proposed equations were compared with those of test results. Most of strength equations underestimated overly test strengths and predictions by Oosterhof et al.'s equation was close to block shear strength of base metal in fillet-welded connections.

Keywords

Acknowledgement

Supported by : 한국연구재단(교육부)

References

  1. Johnson, A.L & Winter, G. (1996). Behavior of stainless steel columns and beams, Journal Structural Division, 92(10), 92-118.
  2. American Iron and Steel Institute(1968). Specification for the design of light gage cold-formed stainless steel structural members, AISI, USA.
  3. Lee, M.J. (1989). Mechanical Properties and Buckling Strength of Stainless Steel Members, Architectural Institute of Korea, AIK, 5(6), 319-326.
  4. Kim, T.S., Jeong, H.Y., Kim, M.S. & Lim, J.S. (2010). An Experimental Study on Behavior of Single Shear Bolted Connections with Thin-walled Stainless Steel, Architectural Institute of Korea, AIK, Vol.26, No.5, pp.11-18. (in Korean).
  5. Architectural Institute of Korea(2009). Korean Building Code and Commentary, AIK, Korea.
  6. American Institute of Steel Construction(2001). Manual of Steel Construction-Load and Resistance Factor Design, AISC, Chicago, IL, USA.
  7. American Institute of Steel Construction(2011). Steel Construction Manual, 14th ed, AISC, Chicago, IL, USA.
  8. Architectural Institute of Korea(2016). Korean Building Code and Commentary, AIK, Korea.
  9. Jo, J.B., Jung, K.S. & Lee, J.W. (2006). Plate Thickness and Weld Size on the Strength of Fillet Welded Lap Joints, Korean Society of Steel Construction, KSSC, 18(3), 331-337.
  10. Kim, T.S. (2013). Ultimate Strength of Fillet-Welded Connection in Thin-Walled Austenitic Stainless Steel, Architectural Institute of Korea, AIK, 29(9), 31-38.
  11. Topkaya, C.A. (2004). Finite element parametric study on block shear failure of steel tension members, Journal of Constructional Steel Research, 60, 1615-1635. https://doi.org/10.1016/j.jcsr.2004.03.006
  12. Topkaya C.A. (2007). Block shear failure of gusset plates with welded connection, Engineering Structures, 29(1), 11-20. https://doi.org/10.1016/j.engstruct.2006.04.003
  13. Oosterhof S.A. & Driver R.G. (2010). Effects of connection geometry on block shear failure of welded lap plate connections, Journal of Constructional Steel Research, 67, 525-532.
  14. Eurocode 3(1996). Design of steel structures - Part 1.3: general rules - Supplementary rules for cold-formed members and sheeting, European Committee for Standardization, Chiswick High Road, London, UK.
  15. Canadian Standards Association(2009). CAN/CSA-S16-09 - Design of Steel Structures, Mississauga (ON), CA.
  16. Korean Standard(2013). Stainless steel welding rods and wires, KS D 7026, Seoul, Korea.
  17. Korean Standard(2008). Stainless steel covered electrodes, KS D 7014, Seoul, Korea.
  18. Korean Standard(2007). Test pieces for tensile test for metallic materials, KS D 0801, Seoul, Korea.
  19. Korean Standard(2003). Method of tensile test for metallic materials, KS D 0802, Seoul, Korea.
  20. Japan Industrial Standards(2011). Metallic materials Tensile testing Method of test at room temperature, JISZ 2241, Japan Industrial Standards, Tokyo.
  21. Kim, T.S. & Kuwamura, H. (2007). Finite element modeling of volted connections in thin-walled stainless steel plates under static shear, Thin-Walled Structures, Vol. 45, No. 4, pp.407-421. https://doi.org/10.1016/j.tws.2007.03.006
  22. Kim, T.S. & Kim, M.S. (2013). An Experimental Study on Structural Behaviors of Double Shear Bolted Connections Fabricated with Ferritic Stainless Steel (STS430), Korean Society of Steel Construction, KSSC, Vol. 25, No. 5, pp.463-474 (in Korean). https://doi.org/10.7781/kjoss.2013.25.5.463
  23. American Institute of Steel Construction(2011). Steel construction manual, USA: AISC, Chicago(IL), USA.
  24. Jo, J.B. & Lee, H.Y. (2012). Proposal of Estimation Equation for Nominal Strength of Longitudinal Fillet Welds with Different Types of Steel, Korean Society of Steel Construction, KSSC, Vol.24, No.5, pp.503-510. (in Korean). https://doi.org/10.7781/kjoss.2012.24.5.503
  25. Hwang, B.K. & Kim, T.S. (2015). Experimental Study on the Ultimate Strength of Ferritic Stainless Steel(STS430) Fillet Welded Connections under tensile load, Proceedings of the 26th Annual Conference, KSSC, pp.47-48. (in Korean).