DOI QR코드

DOI QR Code

A Study on the Control of the Temperature and Relative Humidity in Greenhouse by Adjusting the Amount of Natural Ventilation and Fog Spray Quantity

자연환기량과 포그분무량 조절에 의한 온실 온습도의 동시제어 기법 연구

  • Kim, Youngbok (School of the Agro-system Engineering, Major in the Bio-Machinery Engineering, CALS, IALS, Gyeongsang National University) ;
  • Sung, Hyunsoo (School of the Agro-system Engineering, Major in the Bio-Machinery Engineering, CALS, Gyeongsang National University) ;
  • Hwang, Seungjae (Department of Horticulture, CALS, IALS, Gyeongsang National University) ;
  • Kim, Hyeontae (School of the Agro-system Engineering, Major in the Bio-Machinery Engineering, CALS, IALS, Gyeongsang National University) ;
  • Ryu, Chanseok (School of the Agro-system Engineering, Major in the Bio-Machinery Engineering, CALS, IALS, Gyeongsang National University)
  • 김영복 (경상대학교 애그로시스템공학부 생물산업기계공학전공, 농업생명과학연구원) ;
  • 성현수 (경상대학교 애그로시스템공학부 생물산업기계공학전공, 대학원) ;
  • 황승재 (경상대학교 원예학과, 농업생명과학연구원) ;
  • 김현태 (경상대학교 애그로시스템공학부 생물산업기계공학전공, 농업생명과학연구원) ;
  • 유찬석 (경상대학교 애그로시스템공학부 생물산업기계공학전공, 농업생명과학연구원)
  • Received : 2016.08.06
  • Accepted : 2016.10.10
  • Published : 2016.10.30

Abstract

To develope a greenhouse fog cooling system to control the temperature and relative humidity simultaneously to the target value, a theoretical analysis and experiments were done. The control process includes the measuring of environmental variables, setting and coding of the water and heat balance equations to maintain the target temperature and relative humidity in greenhouse, calculating of the open level of the greenhouse roof window that governs the natural ventilation and spray water quantity, and operating of the motor to open/close the roof window and pump to spray for water. The study results were shown to be very good because the average air temperature in the greenhouse was kept to be about $28.2^{\circ}C$ with the standard deviation of about $0.37^{\circ}C$ compared to the target temperature of $28^{\circ}C$ and the average relative humidity was about 75.2% compared to the target relative humidity was 75% during the experiments. The average outside relative humidity was about 41.0% and the average outside temperature was $27.2^{\circ}C$ with the standard deviation of about $0.54^{\circ}C$. The average solar intensity in the greenhouse was 712.9 W. The wind velocity of outside greenhouse was 0.558 m/s with the standard deviation of 0.46 m/s.

Keywords

References

  1. Arbel, Avraham, Barak, M., and Shklyar, A., Combination of Forced Ventilation and Fogging Systems for Cooling Greenhouses, Article in Biosystems Engineering Vol. 84, No. 1, pp. 45-55, 2003. https://doi.org/10.1016/S1537-5110(02)00216-7
  2. Kim, M. K., Kim, K. S., and Kwon, H. J., The Cooling Effect of Fog Cooling System as Affected by Air Exchange Rate in Natural Ventilation Greenhouse. The Korean Society for Bio_Environment Control. Journal of environment Control, Vol. 10, No. 1, pp. 10-14, 2001.
  3. Kim, J. H., Kim, C. S., Koo, K. H., and Lee, K. M., A Fundamental Study for the Automatic Control System in Greenhouse Using Microcomputer(III) -A variation of temperature and humidity by the window opening ways of the even-Span type house-. Korean Society for Agricultural Machinery. Journal of Biosystems Engineering, Vol. 20, No. 2, pp. 162-172, 1995.
  4. Min, Y. B. et al. Cooling Control of Greenhouse Using Roof Window Ventilation by Simple Fuzzy Algorithm. Institute of Agriculture & Life Science, Gyeongsang National University. Journal of Agriculture & Life Science. Vol. 44, No. 4. pp. 69-77, 2010 (In korean).
  5. Handarto Handarto, Makio Hayashi, Katsumi Ohyama and Kozai, T., Developing control logic for a high-pressure fog cooling system operation for a naturally ventilated greenhouse, Environmental Control in Biology Vol. 44, No. 1, pp. 1-9, 2006. https://doi.org/10.2525/ecb.44.1
  6. Kim, Y. B., Sung, H. S., Yun, N. K., Lee, S. Y., Hwang, S. J., Kim, H. T., and Lee, J. P., Effects of the Open Level of the Side Window on the Control of the Temperature and Relative Humidity in the Fog Cooling Greenhouse, Vol. 45, No. 6, pp. 265-278, 2011.
  7. Shin, I. H., Kang, H. G., Lee, S. D., and Yoo, H. C., Analysis of the ventilation for natural air-conditioning (free cooling), Journal of the Korean Solar Energy Society, Vol. 2010, No. 11, pp. 363-368.
  8. Kim, S. J. and Na, S. Y., A Case Study on the Energy Conservation Design Strategies of the Multipurpose Greenhouse, Journal of the Korean Solar Energy Society, Vol. 26, No. 4, pp.101-107, 2006.
  9. Agmail, Waleed Ibrahim Ramadan, Raphael, Linker and Avraham, Arbel, Robust H-infinity Control of Greenhouse Ventilation and Fogging, Conference Paper of ASABE, Paper No. 096100, January 2009.
  10. Suhardiyanto, Herry and Romdhonah, Yayu, Determination of Convective Coefficient at the Outside Cover of a Monitor Greenhouse in Indonesia, Journal of Applied Sciences in Environmental Vol. 3, No1, pp. 37-46, 2008.
  11. Businger, J. A., The glasshouse climate, In Physics of Plant Environment, Amsterdam, North-Holland, pp. 277-318, 1963.
  12. Kittas, C., Katsoulas, N., Bartzanas, T., Boulard, T., and Mermier, M. Effect of vents' opening and insect screen on greenhouse ventilation, International Conference, Passive and Low Energy Cooling 59 for the Built Environment, pp. 59-64, 2005, Santorini, Greece.
  13. Kittas, C., Boulard, T., and Papadakis, G., Natural ventilation of a greenhouse with ridge and side openings: sensitivity to temperature and wind effects, Transactions of the ASAE, Vol. 40, No.2, pp. 415-425. https://doi.org/10.13031/2013.21268
  14. Molina-Aiza, F. D., Valeraa, D. L., Penaa, A. A., Gilb, J. A., and Lopeza, A., A study of natural ventilation in an Almeria-type greenhouse with insect screens by means of tri-sonic anemometry. Biosystems Engineering. Vol. 104, Issue 2, 2009, pp. 224-242. https://doi.org/10.1016/j.biosystemseng.2009.06.013
  15. Guerrero, F. V., Murat, K., Efren, F. R., Raphael, L., Avraham, A., Chieri, K., and Gene, A. G., Developing a Control Strategy for Greenhouses Equipped with Natural Ventilation and Variable Pressure Fogging: Evapotranspiration Models and Simulated Comparion of Fixed and Variable Pressure Fog Cooling, 2010 ASABE Annual International Meeting, Paper Number: 1009388, 2010.
  16. Teitel, M., Liran, O., Tanny, J., and Barak, M., Wind driven ventilation of a mono-span greenhouse with a rose crop and continuous screened side vents and its effect on flow patterns and microclimate. Biosystems Engineering, Vol. 101, pp. 111-122, 2008. https://doi.org/10.1016/j.biosystemseng.2008.05.012
  17. Liu, S. Z., He, Y., Zhang, Y. B., and Miao, X. W., Prediction and analysis model of temperature and its application to a natural ventilation multi-span plastic greenhouse equipped with insect-proof screen, J Zhejiang Univ Sci B., Vol. 6, No. 6, pp. 523-529, 2005. https://doi.org/10.1631/jzus.2005.B0523
  18. ASHRAE standard 41.6, RA 2006.
  19. Jolliet, O., HORTITRANS. a model for predicting and optimizing humidity and transpiration in greenhouses. Journal of Agricultural Engineering Research 57, pp. 23-37, 1994. https://doi.org/10.1006/jaer.1994.1003
  20. The Korean Federation of Seeding Industries, http://hkyugmyo.or.kr/bbs/board.php?bo_table=0001, Study group for plug seedling production. cafe.daum.net/plugseedling.
  21. Nam, S. W., Application of Heat Balance Model to Design of Ventilating and Cooling Greenhouses. The Korean Society for Bio_Environment Control. Journal of environment Control, Vol.9 ,No.4, pp. 201-206. (2000) ISSN 1229-4675.
  22. Handarto, M., Hayashi, E., Goto and Kozai, T Experimental Verification of Control Logic for Operation of a Fog Cooling System for a Naturally Ventilated Greenhouse. Environment Control in Biology, Vol. 45, No. 1, pp. 47-58, 2007. https://doi.org/10.2525/ecb.45.47
  23. Li, S. and Willitsa, D. H., Comparing low-pressure and high-pressure fogging systems in naturally ventilated greenhouses, Biosystems Engineering, Vol. 101, Issue. 1. pp. 69-77, 2008. https://doi.org/10.1016/j.biosystemseng.2008.06.004
  24. Jang, J. C., Kang, E. C., and Lee, E. J., Peak Cooling and Heating Load and Energy Simulation Study for a Special Greenhouse Facility, Journal of the Korean Solar Energy Society, pp. 72-76, 2009.