• 제목/요약/키워드: Greenhouse temperature

검색결과 1,037건 처리시간 0.023초

열펌프-잠열축열 시스템의 온실 난방 특성 연구 (Greenhouse Heating Characteristics of Heat Pump-Latent Heat Storage System)

  • 강연구;송현갑
    • Journal of Biosystems Engineering
    • /
    • 제25권5호
    • /
    • pp.379-384
    • /
    • 2000
  • In order to use the natural thermal energy as much as possible for greenhouse heating, the air-air heat pump system involved PCM(phase change material) latent heat storage system was composed, and three types of greenhouse heating system(greenhouse system, greenhouse-PCM latent heat storage system, greenhouse-PCM latent heat storage-heat pump system) were recomposed from the greenhouse heating units to analyze the heating characteristics. The results could be concluded as follows; 1) In the greenhouse heated by the heat pump under the solar radiation of 406.39W/$m^2$, the maximum PCM temperature in the latent heat storage system was 24$^{\circ}C$ and the accumulated thermal energy stored in PCM mass of 816kg during the daytime was 100,320kJ. In the greenhouse without heat pump under the maximum solar radiation of 452.83W/$m^2$, the maximum PCM temperature in the latent heat storage system was 22$^{\circ}C$ and the accumulated thermal energy stored during the daytime was 52.250kJ. 2) In the greenhouse-PCM system without heat pump the heat stored in soil layers from the surface to 30cm of the soil depth was 450㎉/$m^2$. 3) In all of the greenhouse heating systems, the difference between the air temperature in greenhouse and the ambient temperature was about 20~23$^{\circ}C$ in the daytime. In the greenhouse without heat pump and PCM latent heat storage system the difference between the ambient temperature and the air temperature in the greenhouse was about 6~7$^{\circ}C$ in the nighttime, in the greenhouse with only PCM latent heat storage system the temperature difference about 7~13$^{\circ}C$ in the nighttime and in the greenhouse with the heat pump and PCM latent heat storage system about 9~14$^{\circ}C$ in the nighttime.

  • PDF

FOG SYSTEM 을 이용한 여름철 온실냉방 (Greenhouse Cooling by Fog System)

  • 서원명
    • 한국농공학회지
    • /
    • 제41권1호
    • /
    • pp.60-71
    • /
    • 1999
  • This study was performed to improve underirable warm greenhouse environment by fog cooling system in summer season. The resultsof droplet size analysis and cooling effects for fog cooling system are summarized as follows ; 1. At the pump pressure of 70kgf/$\textrm{cm}^2$ , the mean (SMD) drop size was 22.6${\mu}{\textrm}{m}$ and the maximum and minimum drop size was 45.68${\mu}{\textrm}{m}$ and 1.73${\mu}{\textrm}{m}$ , respectively, and almost all of the drop size was less than 40${\mu}{\textrm}{m}$. 2. The temperature of fog cooling greenhouse with 60% shading was dropped more than 2$^{\circ}C$ below the ambient temperature , while the greenhouse temperature without shading was 1$^{\circ}C$ higher than the ambient temperature. 3. It was found that fog spraying intervals were significantly influential on cooling effect. 4. When the greenhouse was ventilated sufficiently by natural vent system, green house temperature could be maintained by 2.5$^{\circ}C$ lower than the ambient temperature, while it was difficult to drop the greenhouse temperature below ambient temeperature without sufficient ventilation. 5. It was found that the temperature of experimental greenhouse could be maintained 3$^{\circ}C$ to 14$^{\circ}C$ lower that of control greenhouse though there were variations depending on experimental and weather conditions.

  • PDF

시설원예용 난방온실의 온열환경 분석에 관한 연구 (A Study on Thermal Environment Analysis of a Greenhouse)

  • 송뢰;박윤철
    • 한국지열·수열에너지학회논문집
    • /
    • 제14권3호
    • /
    • pp.15-20
    • /
    • 2018
  • To study the effects of solar energy in a greenhouse, outdoor air temperature and wind speed on inside air temperature, a simulation model for forecasting the greenhouse air temperature was conducted on the basis of the energy and mass balance theory. Application of solar energy to the greenhouse is major area in the renewable energy research and development in order to save energy. Recently, considering the safety and efficiency of the heating of greenhouse, clean energy such as geothermal and solar energy has received much attention. The analysed greenhouse has $50m^2$ of ground area which located in jocheon-ri of Jeju Province. Experiments were carried out to collect data to validate the model. The results showed that the simulated air temperature inside a plastic greenhouse agreed well with the measured data.

잠열축열 장치를 갖춘 온실의 난방 열 특성 예측모형개발 (Modeling of a Greenhouse Equipped with Latent Heat Storage System)

  • 노정근;송현갑
    • 한국태양에너지학회 논문집
    • /
    • 제21권3호
    • /
    • pp.51-60
    • /
    • 2001
  • A greenhouse equipped with latent heat storage system was built to obtain various thermal properties, such as greenhouse air temperature, soil surface temperature, energy flow in latent heat storage, etc., which could be used in validation of greenhouse numerical model to be developed in this study. This numerical model expressed with Newton-Raphson method was programed by C-language and utilized to simulate greenhouse thermal behavior. Greenhouse air temperature and soil surface temperature predicted by the greenhouse model developed in this study were very close to the measured data obtained through almost 3 years of experiment. Therefore, it is concluded that the greenhouse model developed and verified by measured data could be utilized for simulating various thermal behaviors of greenhouses equipped with latent heat storage system to be used for energy saving purposes.

  • PDF

성주지역 참외전용 온실의 모델개발 및 환경분석(1) -성주 시설 참외단지 단동하우스의 온도 분포 특성- (Modelling Development and Environmental Analysis of Oriental Melon Greenhouse in SUNGJU(1) -Characteristics on distribution of air temperature for cultivating oriental melon in tunnel type greenhouse in Sungiu-)

  • 송재관;박규식;구건효
    • 생물환경조절학회지
    • /
    • 제7권4호
    • /
    • pp.311-323
    • /
    • 1998
  • 현재 경북지방의 수박 및 참외재배에 가장 많이 이용되고 있는 대형터널 하우스의 온도 변화를 분석한 결과, 터널하우스 내 기온은 일몰과 함께 강하하여 외기온과 비슷한 온도를 유지하는 시간은 일몰 후 약 2시간 30분 전후로 나타났으며, 자연환기장치인 환기공 및 수동식 측창이 설치되어 재배기간중 하우스내 최고기온은 4$0^{\circ}C$ 이상 유지되지는 않았다. 하우스야간온도는 높이별 위치에 관계없이 거의 같은 온도로 유지되었으며, 재배기간중 야간온도는 외기온보다 2~3$^{\circ}C$정도 높게 유지할 수 있었지만, 외기온이 적온 이하일 때는 보온의 필요성이 있었다. 또 재배기간중 20cm 깊이의 지온은 2$0^{\circ}C$ 이상을 유지할 수 있어서 적정지온 확보에는 문제가 없었으며, 일변동폭은 3~5$^{\circ}C$ 정도이고 관수로 인한 지온저하는 5~6$^{\circ}C$ 정도였다

  • PDF

열펌프에 의한 그린하우스 난방시스템의 열특성과 시뮬레이션 모델개발 (Thermal Characteristics and Simulation Model Development for Greenhouse Heating System with Heat Pump)

  • 노정근;송현갑
    • Journal of Biosystems Engineering
    • /
    • 제26권2호
    • /
    • pp.155-162
    • /
    • 2001
  • The greenhouse heating system with heat pump was built for development of simulation model and validation. The computer simulation model for the system to predict temperature of air and soil and moisture content of soil in the greenhouse were developed, and its validity was justified by actual data. From the analysis of experimentally measured data and the simulation output, following results were obtained. 1. The expected values of inside air temperature for the heating system with heat pump were very much close to the experimental values. 2. In the heating system with heat pump, the expected values of day time surface temperature of soil by computer simulation were very much similar to the measured values, but those of night time were higher than the measured value by at most 2.0$\^{C}$. 3. The simulation model predicted temperature of greenhouse film as of 1$\^{C}$ below than the mean value of ambient air and greenhouse air temperature. 4. Heat loss value of daytime was found to be larger than that of nigh as much as 1.3 to 2.3 times for the heating system with heat pump. 5. In the heating system with heat pump, when the lowest ambient temperature was -8$\^{C}$∼-7$\^{C}$ the air temperature of greenhouse was 5$\^{C}$∼6$\^{C}$, thus the heat pump heating system contributed in greenhouse heating by 13$\^{C}$.

  • PDF

Micro-computer를 이용(利用)한 Greenhouse의 온도제어(溫度制御) System 개발(開發)에 관한 연구(硏究) (A Study on the Development of Greenhouse Temperature Control System by Using Micro-computer)

  • 서원명;민영봉;윤용철
    • Journal of Biosystems Engineering
    • /
    • 제15권2호
    • /
    • pp.134-142
    • /
    • 1990
  • This study was carried out for the development of greenhouse temperature control system by modifying an APPLE-II microcomputer attached with several interface systems. The interface systems are composed of 12 bit A/D converter, output port, multiplexer, time clock, etc. Under the operation of developed system, the greenhouse temperature was to be manipulated within the setting temperatures assumed to be appropriate for certain plant growth. The temperature control equimpents installed in the greenhouse are one-speed propeller type fan and two-phase electric heater, which are selectively started or stopped according to the control logic programmed in the control system. The results are summarized as follows : 1. The difference between two temperatures measured by the developed system and the self-recording thermometer calibrated with standard thermometer was less than $1^{\circ}C$. 2. When the temperature were measurd by 12 bit A/D converter and both electric heater and ventilation fan were controlled by developed ON/OFF logic, greenhouse temperature showed narrow fluctuation bands of less than $1^{\circ}C$ near the setting temperatures. 3. The temperature acquisition and control system developed in this study is expected to be applicable to environment control system such as greenhouse only by modifying the logic based on long term experimental data. 4. In order to reduce the measurement error and to increase the system control efficiency, it is recommended that continuous study should be carried out in the aspect of eliminating various systematic noises and improving the environmental control logic.

  • PDF

A Study on the Greenhouse Water Curtain System: Heat Transfer Characteristics

  • 손원명;한길영
    • 한국농공학회지
    • /
    • 제32권E호
    • /
    • pp.80-87
    • /
    • 1990
  • Energy balance equations Were developed to describe the heat transfer mechanisms in a double layer plastic greenhouse with a water curtain system. Heat transfer variables were determined by using various temperature data measured in a conventional prototype semicircular cross-section greenhouse over a range of water temperatures and water flow rates. The heat transfer coefficient between flowing water and greenhouse air was independent of water flow rates. But the heat transfer coefficient between water surface and the stagnant air space within the double plastic layer was dependent on water flow rates. Substituting the heat transfer coefficients, determined from the energy balance equations in the heat transfer equations, demonstrated various relationships among ambient air temperature, greenhouse air temperature, water temperature, and water flow rates. The heating benefits were linearly related to not only the inside and outside air temperatures but also to the water temperature. The energy conservation effects of the water curtain system were found even initial water temperatures were considerably lower than the greenhouse setting temperatures. Sensitivity analysis for heat transfer coefficients demonstrated that the heat transfer coefficient between greenhouse air and the stagnant air within the plastic layers was the most significant coefficient in the estimation of heating effects.

  • PDF

차광 방법에 따른 온실내부의 온도 변화(농업시설) (Variations of the Inside Temperature of Greenhouse According to Shading Methods)

  • 이현우;이석건;김길동;이종원
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2000년도 학술발표회 발표논문집
    • /
    • pp.321-326
    • /
    • 2000
  • This study was performed to analyze the variation of inside temperature of greenhouse according to shading methods. We used two shading method of external and internal method. The shading effect of external screen was superior to internal screen. Soil temperature of greenhouse without screen was higher than outside soil temperature, but the value of greenhouse with internal and external screen was lower than outside.

  • PDF

온실(溫室) 난방(暖房)을 위한 태양열(太陽熱)-지하(地下) 잠열(潛熱) 축열(蓄熱) 시스템 개발(開發) (Development of Solar Energy-Underground Latent Heat Storage System for Greenhouse Heating)

  • 송현갑;류영선
    • Journal of Biosystems Engineering
    • /
    • 제19권3호
    • /
    • pp.211-221
    • /
    • 1994
  • In this study, to maximize the solar energy utilization for greenhouse heating during the winter season, solar energy-underground latent heat storage system was constructed, and the thermal performance of the system has been analyzed to obtain the basic data for realization of greenhouse solar heating system. The results are summarized as follows. 1. $Na_2SO_4{\cdot}10H_20$ was selected as a latent heat storage material, its physical properties were stabilized and the phase change temperature was controlled at $13{\sim}15^{\circ}C$. 2. Solar radiation of winter season was the lowest value in December, and Jinju area was the highest and the lowest value was shown in Jeju area. 3. The minimum inner air temperature of greenhouse with latent heat storage system(LHSS) was $7.0{\sim}7.5^{\circ}C$ higher than that of greenhouse without LHSS and was $7.0{\sim}11.2^{\circ}C$ higher than the minimum ambient air temperature. 4. Greenhouse heating effect of latent heat storage system was getting higher according to the increase of solar radiation and was not concerned with the variation of minimum ambient air temperature. 5. The relative humidity of greenhouse with latent heat storage system was varied from 50 to 85%, but that of greenhouse without LHSS was varied from 30 to 93%. 6. The heating cost of greenhouse with solar energy-latent heat storage system was about 24% of that with the kerosene heating system.

  • PDF