DOI QR코드

DOI QR Code

Improvement of Performance based wooden building National Fire Safety Codes

성능에 기반을 둔 목조건축물 화재안전기준 개선방안

  • 오택흠 (서울소방재난본부 중랑소방서) ;
  • 박찬석 (우송정보대학교 소방안전관리과)
  • Received : 2016.04.18
  • Accepted : 2016.06.23
  • Published : 2016.06.30

Abstract

Because National Fire Safety Codes is mixed performance criteria and specification, and it defines the fire extinguish equipment type and standards that need to be installed in a building as one method. Therefore, to fully reflect the fire risk characteristics of the building, such as the wooden building there is a limit. In this study, suggested to the performance criteria drawn methodologies through fire load of wooden buildings studies, theory on performance and performance analysis to fire extinguish equipment of the wooden buildings is installed according to current fire safety codes.

Keywords

References

  1. H.J. Park(2014), "The comment of H.J. Park, the member of Congress in the 2014 parliamentary audit", Parliament proceedings of Republic of Korea. 11:2-3.
  2. The Ministry of Cultural Heritage (2014), "Cultural Heritage Administration Statistics Book". the report of the Ministry of Cultural Heritage. 1:23-24.
  3. CIB(1982), "The Performance Concept and its Terminology", CIB Report. 64:11-12.
  4. The Ministry of Public Safety and Security, (2012), "The criteria of PBD Methods of fire extinguish equipments". the law of MPSS. 2:118.
  5. The Ministry of Cultural Heritage (2014), "Guidelines of the cultural heritage disaster prevention system construction business", The regulation of MCH, 4:12.
  6. The Ministry of Public Safety and Security, (2010), "The technical criteria of manual fire extinguisher". the law of MPSS. 13.
  7. The Ministry of Cultural Heritage (2009), "A result of the real fire test for the construction of wooden cultural heritage optimum automatic fire extinguishing equipment". the articles of the Ministry of Cultural Heritage. 1:10-15.
  8. H.S. You, et al.(2008),"Development for the water curtain nozzle and an actual proof fire experiment on wooden building", Fire Society convention Papers(South Korea), 4:37-43.
  9. http://www.nfds.go.kr
  10. NFPA(2013), "Standard for the Installation of Sprinkler Systems", National Fire Protection Association, 2013 Edition:13.
  11. NFPA(2013), "Standard for the Installation of Standpipe and Hose Systems", National Fire Protection Association, 2013 Edition,:14.
  12. NFPA(2013), "Standard for Water Spray Fixed Systems for Fire National Fire Protection Association, 2013 Edition:15.
  13. NFPA(2013), "National Fire Alarm and Signaling Code"National Fire Protection Association, 2013 Edition:72.
  14. NFPA(2001),"Code for Fire Protection of Historic Structures, 2001 Edition:914.