DOI QR코드

DOI QR Code

공동주택의 에너지 부하량 저감을 위한 블라인드 운영스케줄 검토

Blind Optimal Operating Schedule for Reviewing the Energy Load Reduction of Apartment House

  • 마쥔챠오 (부산대학교 건축공학과 대학원) ;
  • 이준기 (부산대학교 건축공학과 대학원) ;
  • 김성훈 (부산대학교 건축공학과 대학원) ;
  • 이갑택 (부산대학교 건축공학과 대학원) ;
  • 이경희 (부산대학교 건축공학과)
  • Ma, Jun-ChaO (Department of Architecture Engineering in the Graduate School, Pusan National University) ;
  • Lee, Jun-Gi (Department of Architecture Engineering in the Graduate School, Pusan National University) ;
  • Kim, Sung-Hoon (Department of Architecture Engineering in the Graduate School, Pusan National University) ;
  • Lee, Gab-Taek (Department of Architecture Engineering in the Graduate School, Pusan National University) ;
  • Lee, Kyung-Hee (Department of Architecture Engineering, Pusan National University)
  • 투고 : 2016.05.27
  • 심사 : 2016.07.27
  • 발행 : 2016.08.31

초록

In this study, through portion of the blind control which the user can adjust the deration and the main loads, night for energy reduction during the review of the energy difference between the cooling and heating load periods in order to present the best operation schedules of the blind control. The result, Cooling period, the venetian blind is installed the day or the day and night CASE adjusted to $0^{\circ}$ was identified as optimal for the operating schedule. Heating period, the day, without installed the blinds, the Venetian blind is installed only at night CASE adjusted to $0^{\circ}$ or $45^{\circ}$ angle of the slats, which have been identified as optimal for the operating schedule.

키워드

참고문헌

  1. U. H. Han, 1988, "A Study on the improvement of the thermal environment in apartment houses", DC thesis, Keimyung University, Daegu, Korea.
  2. G. W. Park and K. H. Lee, 2001, "A Study on the Cooling Load in Relation to Directions of the Apartment Houses", Journal of the Architecture Institute of Korea, Vol. 17, No. 1, pp. 121-128.
  3. S. H. Yoon, H. K. Jang and Y. T. Kim, 2009, "Analysis on the Characteristics of Thermal Load Classified by the Household in Apartment House", Journal of the Architecture Institute of Korea, Vol. 25, No. 10, pp. 289-296.
  4. S. H. Kim, J. G. Lee, Y. T. Kim and K. H. Lee, 2016, "Energy Load according to the Units of Apartment House", Journal of the Korean society for Power System Engineering, Vol. 19, No. 2, pp. 78-83.
  5. D. W. Lee, J. G. Lee, G. T. Lee, Y. T. Kim and K. H. Lee, 2015. "The Study on Lighting Load of Lower-part in Apartment Houses", Journal of the Korean Society for Power System Engineering. Vol. 20, No. 1, pp. 63-68.
  6. G. S. Choi and J. Y. Sohn, 2010. "Energy Performance Evaluation of Apartment Building in Case of Applying a Blind Integrated Window System", Vol. 22, No. 7, pp. 429-435.
  7. D. S. Hwang, 2012. "The Study on the Affection of Indoor Thermal Environment by Blind Location and Angle in Apartment House", MS thesis, Pusan National University, Busan, Korea.
  8. J. G. Lee, G. T. Lee and K. H. Lee, "Comparison of the Energy Load according to the Balcony Types and Blind Installation", Journal of the Korean Society for Power System Engineering. Vol. 19, No. 3, pp. 63-68. https://doi.org/10.9726/kspse.2015.19.3.063