DOI QR코드

DOI QR Code

수중 내 베타선 모니터링 센서 개발을 위한 기초연구

Feasibility Study on Development of an Underwater Beta-ray Monitoring Sensor

  • 투고 : 2016.08.16
  • 심사 : 2016.09.27
  • 발행 : 2016.09.30

초록

In this study, a beta monitoring sensor was developed as a part of basic research for quantitative beta monitoring underwater, and its performance was evaluated using a calibration source. A beta detection sensor was manufactured by using SiPM(silicon photomultiplier) and $CaF_2$:Eu, YAG:Ce, YAP:Ce scintillator. A large-area light guide was introduced to improve beta-ray detection efficiency. As calibration sources, the Beta source $^{90}Sr$, which is the main fission product of a nuclear accident, and the gamma source $^{137}Cs$ are used. In the performance evaluation, it is confirmed that scintillator $CaF_2:Eu$ gives the highest beta-ray detection response. Compared to gamma ray, beta-ray detection responsivity and detection efficiency are verified. Therefore, this study is expected to contribute to basic research in the development of an underwater beta-ray monitoring system.

키워드

참고문헌

  1. H. M. Park and K. S. Joo, "Development of a Real-time Radiation Level Monitoring Sensor for Building an Underwater Radiation Monitoring System", J. Sensor Sci. & Tech., Vol. 24, No. 2, pp. 1-5, 2015. https://doi.org/10.5369/JSST.2015.24.1.1
  2. Y. Zhang, C. Li, D. Liu, Y. Zhang, and Y. Liu, "Monte Carlo simulation of a NaI(Tl) detector for in situ radioactivity measurements in the marine environment", Appl. Radiat. Isot., Vol. 98, pp. 44-48, 2015. https://doi.org/10.1016/j.apradiso.2015.01.009
  3. C. K. Kim, H. T. Kim, J. Y. Kim, C. H. Lee, H. J. Yoo, D. U. Kang, M. S. Cho, M. S. Kim, D. H. Lee, Y. W. Kim, K. T. Lim, S. Y. Yang, G. S. Cho, "Replacement of a photomultiplier tube in a 2-inch thallium-doped sodium iodide gamma spectrometer with silicon photomultipliers and a light guide", Nucl. Eng. Technol., Vol. 47, pp 479-487, 2015. https://doi.org/10.1016/j.net.2015.02.001
  4. http://www.crystals.saint gobain.com/uploadedFiles/SGCrystals/ Documents/CaF2(Eu)%20data%20sheet.pdf/ (retrieved on Aug. 15, 2016).
  5. http://www.hamamatsu.com/resources/pdf/ssd/s13360_series_kapd1052e.pdf/ (retrieved on Aug. 15, 2016).
  6. S. H. Hang, S. H. Shin, H. I. Sim, S. K. Kim, H. S. Jeon, J. S. Jang, J. S. Kim, G. W. Kwon, K. W. Jang, W. J. Yoo and B. S. Lee, "Feasibility Study on Development of a Fiber-Optic Dual Detector to Measure Beta- and Gammarays Simultaneously", Trans. KIEE., Vol. 63, No. 2, pp. 284-290, 2014.
  7. https://ehs.ucsd.edu/rad/radionuclide/Y-90.pdf/(retrieved on Aug. 15, 2016).
  8. https://ehs.ucsd.edu/rad/radionuclide/Sr-90.pdf/(retrieved on Aug. 15, 2016)
  9. G. F. Knoll, Radiation detection and measurement, John Wiley & Sons, New York, pp. 4-5, 2000.
  10. H. M. Park, J. H. Kim, K. H. Park, C. J. Park, W. J. Han and K. S. Joo, "Evaluation of Photon Transmission Efficiency of Light Guides used in Scintillation Detectors using the LightTools Code", J. Radiation Protection., Vol. 41, No. 3, pp. 81-85, 2016. https://doi.org/10.14407/jrpr.2016.41.2.081

피인용 문헌

  1. Development and Comparison of Fiber-Optic Beta Radiation Sensors with Different Diameters of Their Sensing Probes vol.2017, 2017, https://doi.org/10.1155/2017/1452765