DOI QR코드

DOI QR Code

The CO Gas Concentration Characteristics in a Sound Proof Road Tunnel According to the Upper Opening Installation Distance Interval

방음터널 내부의 상부배출구 간격에 따른 CO 농도분포 특성

  • 박명식 (수원과학대학교 건축기계설비)
  • Received : 2016.07.18
  • Accepted : 2016.09.22
  • Published : 2016.09.30

Abstract

When we construct a road near an apartment complex, we consider a soundproof wall. To make residential places quieter, we may consider a soundproof road tunnel. Such a tunnel, however, would become highly concentrated with soot from vehicles whenever a traffic jam might occur. To create an optimum design, this study utilizes the PHOENICS-VR software. The work considers three cases: (1) no openings (2) openings at 30m intervals, and (3) openings at 60m intervals on the upper side of the tunnel. The study finds that in the second case shows CO concentration distributions were 15% less than those without openings. And the CO concentration distributions of the second and third cases are almost the same. The findings suggest that we should make the soundproof tunnel to reduce construction fees.

Keywords

References

  1. ASHAE, "Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings (ANSI Approved)", ASHRAE Standard 62.2, 2016.
  2. B. H. Turk, D. T. Grimsrud, J. T. Brown, K. L. Geisling- Sobotka, J. Harrison, R. J. Prill, "3248 -- Commercial Building Ventilation Rates and Particle Concentrations", ASHRAE Conference Proceeding, 1989.
  3. W. T. Fay, T. H. Kuehn, D. Y. H. Pui, M. H. Bergin, "3263 (RP-531) -- Dust Concentration Modeling for Industrial Operations", ASHRAE Conference Proceeding, 1989.
  4. Elena L. Nirlo, Neil Crain, Richard Corsi and Jeffrey A. Siegel, "Formaldehyde Concentrations and Control in Retail Buildings", AHRAE proceedings, 2013.
  5. Vaculik, F., Plett, E. G., "CH-93-22-2 -- Carbon Dioxide Concentration Based Ventilation Control", AHRAE Conference Proceeding, 1993.
  6. Vaculik, F., Plett, E. G., "3165 -- New Ventilation based on Spatial Distribution of Contaminant Concentration Aided by Numerical Simulation Efficiency Scales", AHRAE Conference Proceeding, 1988.
  7. Larry Dlugosz, CIH, "SE-14-C066 -- Ambient Airborne Particle Concentrations in Hospital Inpatient Rooms", AHRAE Conference Proceeding, 2014.
  8. H. Ezzat Khalifa, Qingyan Chen, Chun Chen, Atila Novoselac, "Seminar 39 -- Evaluating Particle Concentration and Distribution in Industrial and Transportation Ventilation", AHRAE Conference Proceeding, 2013.
  9. D. J. Moschandreas, "AC-83-10-1 -- Pollutant and Pollutant Concentrations Encountered in Various Indoor Environments", ASHRAE Conference Proceeding, 1983.
  10. R. L. Petersen, D. J. Wilson, "VA-89-10-3 -- Analytical Versus Wind Tunnel Determined Concentrations Due to Laboratory Exhaust", ASHRAE Conference Proceeding, 1989.
  11. Xinlei Wang, Yuanhui Zhang, Zhongchao Tan, "DE-05-03-1-Comparison of Different Instruments for Particle Concentration Measurements", ASHRAE Conference Proceeding, 2005.
  12. Levine, K. B., Sterling, E. M., Collett, C. W., "CH-93-22-4 -- Estimation of Outdoor Air Ventilation Rates Using $CO_2$ Concentrations", ASHRAE Conference Proceeding, 1993.
  13. Thompson, R. S. "IN-91-03-2 -- Concentrations from Above-Roof Releases of Laboratory Exhaust - A Wind Tunnel Study", ASHRAE Conference Proceeding, 1991.
  14. Paul W. Francisco, Jeffrey R. Gordon, William B. Rose, "Indoor Combustion Product Concentrations Resulting from the Use of Unvented Gas Fireplaces", ASHRAE Conference Proceeding, 2008.
  15. David Faulkner, William J. Fisk, Douglas P. Sullivan, James M. Thomas, Jr., "Characterizing Building Ventilation with the Pollutant Concentration Index: Results from Field Studies", ASHRAE Conference Proceeding, 1998.
  16. D. J. Wilson, G. Winkel, "HO-2696 (RP-204) -- The Effect of Varying Exhaust Stack Height on Contaminant Concentration at Roof Level", ASHRAE Conference Proceeding, 1982.
  17. Schulman, L. L., Scire, J. S., "IN-91-03-3 -- The Effect of Stack Height, Exhaust Speed, and Wind Direction on Concentrations from a Rooftop Stack", ASHRAE Conference Proceeding, 1991.
  18. Hitomi Tsutsumi, PhD, Fumihiko Shinoda, Shin-ichi Tanabe, Hitomi Takeuchi, Nobuhiro Hirasuga, Motohiko Iwase, Masakazu Setsujima, Kouichi Nakahara, "Effects of Various Indoor Environmental Factors on the Decay of Chlorine Dioxide Gas Concentration: Implication on Its Use Against Pandemic Flu", ASHRAE Conference Proceeding, 2011.
  19. Daniel J. Hirnikel, "4606 -- Validation of a CFD Model for Temperature and Particulate Concentration in a Test Room with Mixed Air and Displacement Ventilation", ASHRAE Conference Proceeding, 2003.
  20. Kishor Khankari, "ST-16-C004 -- Analysis of Contaminant Flow Path and Laboratory Ventilation Effectiveness", ASHRAE Conference Proceeding, 2016.