DOI QR코드

DOI QR Code

Laparoscopic Splenectomy in Two Dogs Using SonicisionTM

  • Park, Tae-Yeong (Laboratory of Veterinary Surgery & Behavior, College of Veterinary Medicine, Gyeongsang National University) ;
  • Kim, Hyun-Jin (Laboratory of Veterinary Surgery & Behavior, College of Veterinary Medicine, Gyeongsang National University) ;
  • Kim, Jung-Hoon (Laboratory of Veterinary Surgery & Behavior, College of Veterinary Medicine, Gyeongsang National University) ;
  • Kim, Jun-Min (Laboratory of Veterinary Surgery & Behavior, College of Veterinary Medicine, Gyeongsang National University) ;
  • Seok, Seong-Hoon (Laboratory of Veterinary Surgery & Behavior, College of Veterinary Medicine, Gyeongsang National University) ;
  • Jung, Dong-In (Laboratory of Veterinary Internal Medicine, College of Veterinary Medicine, Gyeongsang National University) ;
  • Hong, Il-Hwa (Laboratory of Veterinary Pathology, College of Veterinary Medicine, Gyeongsang National University) ;
  • Lee, Hee-Chun (Laboratory of Veterinary Medical Imaging, College of Veterinary Medicine, Gyeongsang National University) ;
  • Yeon, Seong-Chan (Laboratory of Veterinary Surgery & Behavior, College of Veterinary Medicine, Gyeongsang National University)
  • 투고 : 2016.06.02
  • 심사 : 2016.08.16
  • 발행 : 2016.08.31

초록

A 10-year-old, 24.1 kg, intact female Siberian husky dog (case 1) and 11-year-old, 5.0 kg, intact male Shihtzu dog (case 2) presented with chief complaints of polydipsia, anorexia, vomiting and exercise intolerance (case 1) and stranguria (case 2). Splenic nodule (case 1) and mass (case 2) were identified in these patients through ultrasonographic examination. Laparoscopic splenectomy was conducted for the histopathologic evaluation. In addition, laparoscopic ovariohysterectomy, liver biopsy (case 1) and castration (case 2) were performed for treatment or diagnosis of primary symptoms. Under general anesthesia, 5 mm three-portal access laparoscopic splenectomy was performed using the Sonicision$^{TM}$ equipment. The dogs were rotated onto right lateral recumbency. The spleen was elevated using a fan or goldfinger retractor, which revealed the ventral aspect of the spleen. Resection of vessels was started at the caudal aspect of the spleen using the Sonicision$^{TM}$. The excised spleen was removed from the abdominal cavity using a 12 mm endo-bag via the enlarged instrument portal. There were no post-operative complications in either patient. Histopathologic diagnoses were splenic lymphoid hyperplasia (case 1) and splenic nodular hyperplasia (case 2). Based on our experience, laparoscopic splenectomy is sufficient to replace traditional splenectomy in small animal surgery. The use of the Sonicision$^{TM}$ could be a novel surgical technique for three-portal laparoscopic splenectomy, regardless of patient size.

키워드

참고문헌

  1. Brunt LM, et al., Comparative analysis of laparoscopic versus open splenectomy. Am J Surg 1996; 172: 596-601. https://doi.org/10.1016/S0002-9610(96)00241-3
  2. Cimino WW and LJ Bond, Physics of ultrasonic surgery using tissue fragmentation: Part I. Ultrasound Med Biol 1996; 22: 89-100. https://doi.org/10.1016/0301-5629(95)02021-7
  3. Delaitre B and B Maignien, Laparoscopic splenectomy: One case. Press Med 1991: 20.
  4. Gelmini R, et al., Sutureless and stapleless laparoscopic splenectomy using radiofrequency: LigaSure device. Surg Endosc 2006; 20: 991-994. https://doi.org/10.1007/s00464-005-0470-5
  5. Glasgow RE and SJ Mulvihill, Laparoscopic splenectomy. World J Surg 1999; 23: 384-388. https://doi.org/10.1007/PL00012313
  6. Katkhouda N, et al., Laparoscopic splenectomy: Outcome and efficacy in 103 consecutive patients. Ann Surg 1998; 228: 568-578. https://doi.org/10.1097/00000658-199810000-00013
  7. Kennedy JS, et al., High-burst-strength, feedback-controlled bipolar vessel sealing. Surg Endosc 1998; 12: 876-878. https://doi.org/10.1007/s004649900733
  8. Kim FJ, et al., Temperature safety profile of laparoscopic devices: Harmonic ACE (ACE), Ligasure V (LV), and plasma trisector (PT). Surg Endosc 2008; 22: 1464-1469. https://doi.org/10.1007/s00464-007-9650-9
  9. Kim FJ, et al., Evaluation of emissivity and temperature profile of laparoscopic ultrasonic devices (blades and passive jaws). Surg Endosc 2015; 29: 1179-1184. https://doi.org/10.1007/s00464-014-3787-0
  10. Park A, EM Targarona, and M Trias, Laparoscopic surgery of the spleen: State of the art. Langenbeck's Archives of Surgery 2001; 386: 230-239. https://doi.org/10.1007/s004230100222
  11. Stedile R, et al., Laparoscopic versus open splenectomy in dogs. Pesq Vet Bras 2009; 29: 653-660. https://doi.org/10.1590/S0100-736X2009000800009
  12. Tillson DM, Spleen. Textbook of Small Animal Surgery 2003: 1046-1062.
  13. Tsirline VB, et al., Evaluation of an innovative, cordless ultrasonic dissector. Sur Innov 2013; 20: 524-529. https://doi.org/10.1177/1553350612471206
  14. Zhang JT, et al., Laparoscopic splenectomy in goats. Vet Surg 2009; 38: 406-410. https://doi.org/10.1111/j.1532-950X.2009.00507.x