Seismic Capacity of Column-Rafter Joint for Metal Building System(PEB)

공업화박판강구조(PEB)를 위한 Column-Rafter 접합부의 내진성능

  • Received : 2016.05.09
  • Accepted : 2016.08.11
  • Published : 2016.08.30

Abstract

The purpose of this research is to develop the seismic reinforcement for PEB structure system and evaluate the seismic performance of PEB frames under cyclic load. The final goal of this research is to propose PEB system as steel ordinary moment frame system. Finite element analysis is performed before the experiment to develop the seismic joint reinforcement details of PEB structure system, called PI joint(${\pi}$ joint). PI joint has two types of joint details. One is tapered plate on the inner flange of rafter and column connection and the other is C-plate on the panel zone combined with tapered plate type. In this paper, the cyclic loading test is performed with three 3/8 scaled down PEB sub-assemblage frame specimen. The seismic performance of the specimens is evaluated by energy dissipation capacity, strength and response modification factor(R factor). As a result, it could be figured out that PEB can be categorized as steel ordinary moment frame and PI joint can enhance the seismic capacity of PEB structure.

Keywords

Acknowledgement

Supported by : 동부제철(주)

References

  1. ANSI, A., AISC 341-05 (2005). Seismic provisions for structural steel buildings, American Institute of Steel Construction, Inc. Chicago, IL.
  2. Bachman, R., & Shoemaker, W. (2004). MBMA Seismic Design Guide for Metal Building Systems 2000 IBC Edition.
  3. Beamish, M. (1987). Cyclic loading tests on steel portal frame knee joints, Bulletin of the New Zealand National Society for Earthquake Engineering, 20(1), 42-51.
  4. Buchanan, A., & R. Fairweather. (1993). Seismic design of glulam structures. Bulletin of the New Zealand National Society for Earthquake Engineering, 26(4), 415-436.
  5. Chen, C.-C., & C.-C. Lin. (2013). Seismic performance of steel beam-to-column moment connections with tapered beam flanges, Engineering structures, 48, 588-601. https://doi.org/10.1016/j.engstruct.2012.10.003
  6. Chung, K. S., Jeon, B. H., Park, M. W., & Do, B. H. (2012). Experimental Study on Structural Behavior of Tapered non-compact Frame with Snug-tightened Conditions, Journal of Korean Society of Steel Construction, 24(3), 257-265. https://doi.org/10.7781/kjoss.2012.24.3.257
  7. Code, Korea Building. (2009). Architectural institute of Korea, Seoul.
  8. Engelhardt, M. D., & T. A. Sabol. (1998). Reinforcing of steel moment connections with cover plates: benefits and limitations, Engineering structures, 20(4), 510-520. https://doi.org/10.1016/S0141-0296(97)00038-2
  9. Gholami, M., Deylami, A., & Tehranizadeh, M. (2013). Seismic performance of flange plate connections between steel beams and box columns, Journal of Constructional Steel Research, 84, 36-48. https://doi.org/10.1016/j.jcsr.2012.11.011
  10. Hibbitt, H., Karlsson, B., & Sorensen, P. (2011). Abaqus analysis user's manual version 6.10. Dassault Systemes Simulia Corp.: Providence, RI, USA.
  11. Hong, J.-K., & C.-M. Uang. (2012). Cyclic testing of a metal building moment frame system with web-tapered members, Journal of constructional steel research, 70, 248-255. https://doi.org/10.1016/j.jcsr.2011.09.005
  12. Ju, Y.-K. (2006). Simplified dynamic inelastic analysis of tall buildings, Proceedings of the Institution of Civil Engineers-Structures and Buildings, 159(3), 165-178. https://doi.org/10.1680/stbu.2006.159.3.165
  13. Ju, Y. K., Kim, M. H., Kim, J., & Kim, S. D. (2009). Component tests of buckling-restrained braces with unconstrained length, Engineering structures, 31(2), 507-516. https://doi.org/10.1016/j.engstruct.2008.09.014
  14. Kim, S. D., Kim, S. S., & Ju, Y. K. (2008). Strength evaluation of beam-column connection in the weak axis of H-shaped column, Engineering Structures, 30(6), 1699-1710. https://doi.org/10.1016/j.engstruct.2007.11.008
  15. Kim, Y. J., Kim, M. H., Jung, I. Y., Ju, Y. K., & Kim, S. D. (2011). Experimental investigation of the cyclic behavior of nodes in diagrid structures, Engineering Structures, 33(7), 2134-2144. https://doi.org/10.1016/j.engstruct.2011.03.004
  16. Lee, C. (2002). General Issues Influencing Improved Seismic Performance of Welded Steel Moment Connections, Journal of Korean Society of Steel Construction, 14(4), 50-61.
  17. Lee, H., & C. C. (1996). A Study on the Similitude of Member Behavior for Small-Scale Modeling of Reinforced Concrete Structure, Journal of the Korea Concrete Institute, 8(3), 9.
  18. Leelataviwat, S., Goel, S. C., & Stojadinovic, B. (2002). Energy-based seismic design of structures using yield mechanism and target drift, Journal of Structural Engineering, 128(8), 1046-1054. https://doi.org/10.1061/(ASCE)0733-9445(2002)128:8(1046)
  19. Oh, J., Ju, Y. K., Hwang, K. J., Kim, S. D., & Lho, S. H. (2016). FREE node for a single layer free-form envelope subjected to bending moment, Engineering Structures, 106, 25-35. https://doi.org/10.1016/j.engstruct.2015.09.030
  20. Park, M., Ju, Y.K., & Kim, S.D. (2006). Introduction of Improved Seismic Provision for Buckling-Restrained Brace, Journal of Korean Society of Steel Construction, 18(1), 63-69
  21. Popov, E. P., & S. M. Takhirov. (2002). Bolted large seismic steel beam-to-column connections Part 1: experimental study, Engineering structures, 24(12), 1523-1534. https://doi.org/10.1016/S0141-0296(02)00086-X
  22. Saffari, H., Rahgozar, R., & Jahanshahi, R. (2008). An efficient method for computation of effective length factor of columns in a steel gabled frame with tapered members, Journal of Constructional Steel Research, 64(4), 400-406. https://doi.org/10.1016/j.jcsr.2007.09.001
  23. Smith, M. D. (2013). Seismic Testing and Analytical Studies for the Development of New Seismic Force Resisting Systems for Metal Buildings, Thesis, University of California, San Diego.
  24. Tsavdaridis, K. D., Faghih, F., & Nikitas, N. (2014, October). Seismic evaluation of reduced web section (RWS) moment connections, Proceedings of the Hellenic National Conference of Steel Structures. Leeds.
  25. Uang, C.-M. (1991). Establishing R(or Rw) and Cd factors for building seismic provisions, Journal of structural engineering, 117(1), 19-28. https://doi.org/10.1061/(ASCE)0733-9445(1991)117:1(19)
  26. Vetr, M., Miri, M., & Haddad, A. (2012). Seismic Behavior of a New Reduced Beam Section Connection by Drilled Holes Arrangement (RBS_DHA) on the Beam Flanges through Experimental Studies, 15th World Conference of Earthquake Engineering (15WCEE), Lisbon, Portugal.

Cited by

  1. Experimental Study on the Flexural Capacity of H-shaped Steel Beam with the Concrete-Filled Tubular Flange vol.18, pp.4, 2018, https://doi.org/10.9798/KOSHAM.2018.18.4.1