References
- Alt V, Hannig M, WOstmann B, Balkenhol M. Fracture strength of temporary fixed partial dentures: CAD/CAM versus directly fabricated restorations. Dent Mater 2011;27:339-47. https://doi.org/10.1016/j.dental.2010.11.012
- Schoenbaum TR. Dentistry in the digital age: an update. Dent Today 2012;31:108, 110, 112-3.
- Poticny DJ, Klim J. CAD/CAM in-office technology: innovations after 25 years for predictable, esthetic outcomes. J Am Dent Assoc 2010;141:5S-9S. https://doi.org/10.14219/jada.archive.2010.0356
- Stawarczyk B, Ender A, Trottmann A, Ozcan M, Fischer J, Hämmerle CH. Load-bearing capacity of CAD/CAM milled polymeric three-unit fixed dental prostheses: effect of aging regimens. Clin Oral Investig 2012;16:1669-77. https://doi.org/10.1007/s00784-011-0670-4
- Tinschert J, Zwez D, Marx R, Anusavice KJ. Structural reliability of alumina-, feldspar-, leucite-, mica- and zirconiabased ceramics. J Dent 2000;28:529-35. https://doi.org/10.1016/S0300-5712(00)00030-0
- Stawarczyk B, Sener B, Trottmann A, Roos M, Ozcan M, Hammerle CH. Discoloration of manually fabricated resins and industrially fabricated CAD/CAM blocks versus glassceramic: effect of storage media, duration, and subsequent polishing. Dent Mater J 2012;31:377-83. https://doi.org/10.4012/dmj.2011-238
- Stawarczyk B, Ozcan M, Trottmann A, Schmutz F, Roos M, Hammerle C. Two-body wear rate of CAD/CAM resin blocks and their enamel antagonists. J Prosthet Dent 2013;109:325-32. https://doi.org/10.1016/S0022-3913(13)60309-1
- Luthardt RG, Holzhüter MS, Rudolph H, Herold V, Walter MH. CAD/CAM-machining effects on Y-TZP zirconia. Dent Mater 2004;20:655-62. https://doi.org/10.1016/j.dental.2003.08.007
- Lin WS, Ercoli C, Feng C, Morton D. The effect of core material, veneering porcelain, and fabrication technique on the biaxial flexural strength and weibull analysis of selected dental ceramics. J Prosthodont 2012;21:353-62. https://doi.org/10.1111/j.1532-849X.2012.00845.x
-
Addison O, Cao X, Sunnar P, Fleming GJ. Machining variability impacts on the strength of a
CAD-CAM ceramic. Dent Mater 2012;28:880-7. https://doi.org/10.1016/j.dental.2012.04.017 - El Zohairy AA, De Gee AJ, Mohsen MM, Feilzer AJ. Microtensile bond strength testing of luting cements to prefabricated CAD/CAM ceramic and composite blocks. Dent Mater 2003;19:575-83. https://doi.org/10.1016/S0109-5641(02)00107-0
- 3M ESPE. Lava ultimate technical product profile: 2011. Available at: http://multimedia.3m.com/mws/media/781394O/lava-ultimate-technical-product-profile golbal.pdf
- Chen C, Trindade FZ, de Jager N, Kleverlaan CJ, Feilzer AJ. The fracture resistance of a CAD/CAM Resin Nano Ceramic (RNC) and a CAD ceramic at different thicknesses. Dent Mater 2014;30:954-62. https://doi.org/10.1016/j.dental.2014.05.018
- Joda T, Huber S, Bürki A, Zysset P, Bragger U. Influence of Abutment Design on Stiffness, Strength, and Failure of Implant-Supported Monolithic Resin Nano Ceramic (RNC) Crowns. Clin Implant Dent Relat Res 2015;17:1200-7. https://doi.org/10.1111/cid.12215
- Vargas MA, Bergeron C, Diaz-Arnold A. Cementing all-ceramic restorations: recommendations for success. J Am Dent Assoc 2011;142:20S-4S. https://doi.org/10.14219/jada.archive.2011.0339
- Spitznagel FA, Horvath SD, Guess PC, Blatz MB. Resin bond to indirect composite and new ceramic/polymer materials: a review of the literature. J Esthet Restor Dent 2014;26:382-93. https://doi.org/10.1111/jerd.12100
- el-Mowafy O. The use of resin cements in restorative dentistry to overcome retention problems. J Can Dent Assoc 2001;67:97-102.
- Sorensen JA, Kang SK, Avera SP. Porcelain-composite interface microleakage with various porcelain surface treatments. Dent Mater 1991;7:118-23. https://doi.org/10.1016/0109-5641(91)90057-6
- Thompson JY, Stoner BR, Piascik JR, Smith R. Adhesion/cementation to zirconia and other non-silicate ceramics: where are we now? Dent Mater 2011;27:71-82. https://doi.org/10.1016/j.dental.2010.10.022
- Semmelman JO, Kulp PR. Silane bonding porcelain teeth to acrylic. J Am Dent Assoc 1968;76:69-73. https://doi.org/10.14219/jada.archive.1968.0017
- Jochen DG, Caputo AA. Composite resin repair of porcelain denture teeth. J Prosthet Dent 1977;38:673-9. https://doi.org/10.1016/0022-3913(77)90013-0
- Ferrando JM, Graser GN, Tallents RH, Jarvis RH. Tensile strength and microleakage of porcelain repair materials. J Prosthet Dent 1983;50:44-50. https://doi.org/10.1016/0022-3913(83)90164-6
- Blatz MB, Sadan A, Kern M. Resin-ceramic bonding: a review of the literature. J Prosthet Dent 2003;89:268-74. https://doi.org/10.1067/mpr.2003.50
- Ozcan M. Evaluation of alternative intra-oral repair techniques for fractured ceramic-fused-to-metal restorations. J Oral Rehabil 2003;30:194-203. https://doi.org/10.1046/j.1365-2842.2003.01037.x
- Amaral R, Ozcan M, Bottino MA, Valandro LF. Microtensile bond strength of a resin cement to glass infiltrated zirconiareinforced ceramic: the effect of surface conditioning. Dent Mater 2006;22:283-90. https://doi.org/10.1016/j.dental.2005.04.021
- Ozcan M. The use of chairside silica coating for different dental applications: a clinical report. J Prosthet Dent 2002;87:469-72. https://doi.org/10.1067/mpr.2002.124365
- Bailey LF, Bennett RJ. DICOR surface treatments for enhanced bonding. J Dent Res 1988;67:925-31. https://doi.org/10.1177/00220345880670060701
- Egilmez F, Ergun G, Cekic-Nagas I, Vallittu PK, Ozcan M, Lassila LV. Effect of surface modification on the bond strength between zirconia and resin cement. J Prosthodont 2013;22:529-36. https://doi.org/10.1111/jopr.12030
- Sorensen JA, Engelman MJ, Torres TJ, Avera SP. Shear bond strength of composite resin to porcelain. Int J Prosthodont 1991;4:17-23.
- Chen JH, Matsumura H, Atsuta M. Effect of different etching periods on the bond strength of a composite resin to a machinable porcelain. J Dent 1998;26:53-8. https://doi.org/10.1016/S0300-5712(96)00078-4
- Chen JH, Matsumura H, Atsuta M. Effect of etchant, etching period, and silane priming on bond strength to porcelain of composite resin. Oper Dent 1998;23:250-7.
- Szep S, Gerhardt T, Gockel HW, Ruppel M, Metzeltin D, Heidemann D. In vitro dentinal surface reaction of 9.5% buffered hydrofluoric acid in repair of ceramic restorations: a scanning electron microscopic investigation. J Prosthet Dent 2000;83:668-74. https://doi.org/10.1067/mpr.2000.106873
- Braga RR, Meira JB, Boaro LC, Xavier TA. Adhesion to tooth structure: a critical review of "macro" test methods. Dent Mater 2010;26:e38-49.
- Scherrer SS, Cesar PF, Swain MV. Direct comparison of the bond strength results of the different test methods: a critical literature review. Dent Mater 2010;26:e78-93.
- Papia E, Larsson C, du Toit M, Vult von Steyern P. Bonding between oxide ceramics and adhesive cement systems: a systematic review. J Biomed Mater Res B Appl Biomater 2014;102:395-413. https://doi.org/10.1002/jbm.b.33013
- Sano H, Shono T, Sonoda H, Takatsu T, Ciucchi B, Carvalho R, Pashley DH. Relationship between surface area for adhesion and tensile bond strength-evaluation of a micro-tensile bond test. Dent Mater 1994;10:236-40. https://doi.org/10.1016/0109-5641(94)90067-1
- Pashley DH, Carvalho RM, Sano H, Nakajima M, Yoshiyama M, Shono Y, Fernandes CA, Tay F. The microtensile bond test: a review. J Adhes Dent 1999;1:299-309.
- Blatz MB, Phark JH, Ozer F, Mante FK, Saleh N, Bergler M, Sadan A. In vitro comparative bond strength of contemporary self-adhesive resin cements to zirconium oxide ceramic with and without air-particle abrasion. Clin Oral Investig 2010;14:187-92. https://doi.org/10.1007/s00784-009-0278-0
- Soares CJ, Soares PV, Pereira JC, Fonseca RB. Surface treatment protocols in the cementation process of ceramic and laboratory-processed composite restorations: a literature review. J Esthet Restor Dent 2005;17:224-35. https://doi.org/10.1111/j.1708-8240.2005.tb00119.x
- Borges GA, Sophr AM, de Goes MF, Sobrinho LC, Chan DC. Effect of etching and airborne particle abrasion on the microstructure of different dental ceramics. J Prosthet Dent 2003;89:479-88. https://doi.org/10.1016/S0022-3913(02)52704-9
- Swift EJ Jr, Brodeur C, Cvitko E, Pires JA. Treatment of composite surfaces for indirect bonding. Dent Mater 1992;8:193-6. https://doi.org/10.1016/0109-5641(92)90082-N
- Kern M, Thompson VP. Sandblasting and silica coating of a glass-infiltrated alumina ceramic: volume loss, morphology, and changes in the surface composition. J Prosthet Dent 1994;71:453-61. https://doi.org/10.1016/0022-3913(94)90182-1
- Hantsche H. Comparison of basic principles of the surfacespecific analytical methods: AES/SAM, ESCA (XPS), SIMS, and ISS with X-ray microanalysis, and some applications in research and industry. Scanning 1989;11:257-80. https://doi.org/10.1002/sca.4950110602
- Pashley DH, Sano H, Ciucchi B, Yoshiyama M, Carvalho RM. Adhesion testing of dentin bonding agents: a review. Dent Mater 1995;11:117-25. https://doi.org/10.1016/0109-5641(95)80046-8
- Imamura GM, Reinhardt JW, Boyer DB, Swift EJ Jr. Enhancement of resin bonding to heat-cured composite resin. Oper Dent 1996;21:249-56.
- Janda R, Roulet JF, Wulf M, Tiller HJ. A new adhesive technology for all-ceramics. Dent Mater 2003;19:567-73. https://doi.org/10.1016/S0109-5641(02)00106-9
- Stawarczyk B, Krawczuk A, Ilie N. Tensile bond strength of resin composite repair in vitro using different surface preparation conditionings to an aged CAD/CAM resin nanoceramic. Clin Oral Investig 2015;19:299-308. https://doi.org/10.1007/s00784-014-1269-3
- D’Arcangelo C, Vanini L. Effect of three surface treatments on the adhesive properties of indirect composite restorations. J Adhes Dent 2007;9:319-26.
- Behr M, Proff P, Kolbeck C, Langrieger S, Kunze J, Handel G, Rosentritt M. The bond strength of the resin-to-zirconia interface using different bonding concepts. J Mech Behav Biomed Mater 2011;4:2-8. https://doi.org/10.1016/j.jmbbm.2010.08.002
- Lebon N, Tapie L, Vennat E, Mawussi B. Influence of CAD/CAM tool and material on tool wear and roughness of dental prostheses after milling. J Prosthet Dent 2015;114:236-47. https://doi.org/10.1016/j.prosdent.2014.12.021
Cited by
- Effect of alumina-blasting pressure on adhesion of CAD/CAM resin block to dentin vol.37, pp.5, 2018, https://doi.org/10.4012/dmj.2017-237
- Microtensile bond strengths of adhesively bonded polymer-based CAD/CAM materials to dentin pp.1881-1361, 2019, https://doi.org/10.4012/dmj.2017-442
- Roughness, surface energy, and superficial damages of CAD/CAM materials after surface treatment vol.22, pp.8, 2018, https://doi.org/10.1007/s00784-018-2365-6
- Surface deterioration of monolithic CAD/CAM restorative materials after artificial abrasive toothbrushing vol.10, pp.4, 2018, https://doi.org/10.4047/jap.2018.10.4.271
- Effect of Different Surface Treatment Methods on Micro-Shear Bond Strength of CAD-CAM Restorative Materials to Resin Cement. vol.33, pp.2, 2019, https://doi.org/10.1080/01694243.2018.1514992
- Dental Cements for Luting and Bonding Restorations vol.61, pp.4, 2017, https://doi.org/10.1016/j.cden.2017.06.006
- Adhesive Systems Used in Indirect Restorations Cementation: Review of the Literature vol.7, pp.3, 2019, https://doi.org/10.3390/dj7030071
- Bonding Strength of Universal Adhesives to Indirect Substrates: A Meta‐Analysis of in Vitro Studies vol.29, pp.4, 2016, https://doi.org/10.1111/jopr.13147
- Repair bond strength of resin composite to three aged CAD/CAM blocks using different repair systems vol.12, pp.3, 2020, https://doi.org/10.4047/jap.2020.12.3.131
- Influence of surface treatment on bonding of resin luting cement to CAD/CAM composite blocks vol.39, pp.5, 2016, https://doi.org/10.4012/dmj.2019-247
- Influence of Low-Pressure Plasma on the Surface Properties of CAD-CAM Leucite-Reinforced Feldspar and Resin Matrix Ceramics vol.10, pp.24, 2016, https://doi.org/10.3390/app10248856
- Effect of Different Surface Treatment Methods on Bond Strength of Dental Ceramics to Dental Hard Tissues: A Systematic Review vol.26, pp.5, 2021, https://doi.org/10.3390/molecules26051223
- Effect of Two Immediate Dentin Sealing Approaches on Bond Strength of Lava™ CAD/CAM Indirect Restoration vol.14, pp.7, 2016, https://doi.org/10.3390/ma14071629
- Comparison of Mechanical Properties of Chairside CAD/CAM Restorations Fabricated Using a Standardization Method vol.14, pp.11, 2021, https://doi.org/10.3390/ma14113115
- Shear‐bond strength and optical properties of short fiber‐reinforced CAD/CAM composite blocks vol.129, pp.5, 2016, https://doi.org/10.1111/eos.12815