CAD-CAM Konus type 부착장치를 이용한 하악 임플란트 피개의치 보철수복 증례

Mandibular implant-supported overdenture using CAD-CAM Konus type attachment: A case report

  • 박종희 (전북대학교 치의학전문대학원 치과보철학교실 및 구강생체과학연구소) ;
  • 김인주 (전북대학교 치의학전문대학원 치과보철학교실 및 구강생체과학연구소) ;
  • 김경아 (을지대학교 의과대학 치과학교실) ;
  • 송광엽 (전북대학교 치의학전문대학원 치과보철학교실 및 구강생체과학연구소) ;
  • 서재민 (전북대학교 치의학전문대학원 치과보철학교실 및 구강생체과학연구소)
  • Park, Jong-Hee (Department of Prosthodontics, School of Dentistry and Institute of Oral Bio-Science, Chonbuk National University) ;
  • Kim, In-Ju (Department of Prosthodontics, School of Dentistry and Institute of Oral Bio-Science, Chonbuk National University) ;
  • Kim, Kyoung-A (Department of Dentistry, School of Medicine, Eulji University) ;
  • Song, Kwang-Yeob (Department of Prosthodontics, School of Dentistry and Institute of Oral Bio-Science, Chonbuk National University) ;
  • Seo, Jae-Min (Department of Prosthodontics, School of Dentistry and Institute of Oral Bio-Science, Chonbuk National University)
  • 투고 : 2015.08.28
  • 심사 : 2015.09.22
  • 발행 : 2016.07.29

초록

하악 완전 무치악 환자의 보철수복에 있어 임플란트 식립 후 피개의치 제작은 첫 번째 치료 옵션으로 고려된다. 코너스 타입 부착장치를 이용한 피개의치는 견고한 지지를 제공하고 cross arch stabilization을 이루도록 하여 교합압을 균일하게 분산시키며, 의치에 의한 이차 고정으로 장기간의 안정성을 제공한다. 최근 소개된 팔라듐-은(Pd-Ag) 합금(Innovium)은 팔라듐, 은, 금 등의 귀금속 함량이 72% 이상인 CAD-CAM 시스템 전용 귀금속 합금으로 코너스 타입 부착장치를 제작하는데 적합한 물성을 가지고 있다. 본 증례에서는 완전 무치악 환자에서 상악에는 통상적인 총의치, 하악에는 임플란트를 4개 식립한 후에 코너스 타입 부착장치 피개의치 수복을 하였다. CAD-CAM 시스템을 이용하여 팔라듐-은 합금(Innovium)으로 제작된 코너스 타입 부착장치를 장착하였으며 이를 통해 의치의 유지와 안정을 향상시켰으며 만족할 만한 결과를 얻었기에 보고하고자 한다.

In edentulous mandible, implant supported overdenture was considered as a first treatment option. Konus type attachment supplies rigid support and cross arch stabilization so that more favorable force transmission and distribution can be attained. In the dentistry, computer aided design-computer aided manufacturing (CAD-CAM) system makes it possible to fabricate restorations with high precision and effectiveness. Recently, Palladium-silver (Pd-Ag) alloy which is millable has been developed. This article presents that application of CAD-CAM Konus type attachment can be provide satisfactory stability and function on four-implant supported mandibular overdenture.

키워드

참고문헌

  1. Zarb GA, Bolender CL, Eckert S, Fenton A, Jacob R, Mericske-Stern R. Prosthodontic treatment for edentulous patients. Complete dentures and implant supported prostheses 12th ed, St. Louis: Mosby; 2004.
  2. Feine JS, Carlsson GE, Awad MA, Chehade A, Duncan WJ, Gizani S, Head T, Lund JP, MacEntee M, Mericske-Stern R, Mojon P, Morais J, Naert I, Payne AG, Penrod J, Stoker GT, Tawse- Smith A, Taylor TD, Thomason JM, Thomson WM, Wismeijer D. The McGill consensus statement on overdentures. Mandibular two-implant overdentures as first choice standard of care for edentulous patients. Montreal, Quebec, May 24-25, 2002. Int J Oral Maxillofac Implants 2002;17:601-2.
  3. Thomason JM, Feine J, Exley C, Moynihan P, Muller F, Naert I, Ellis JS, Barclay C, Butterworth C, Scott B, Lynch C, Stewardson D, Smith P, Welfare R, Hyde P, McAndrew R, Fenlon M, Barclay S, Barker D. Mandibular two implant-supported overdentures as the first choice standard of care for edentulous patients--the York Consensus Statement. Br Dent J 2009;207:185-6. https://doi.org/10.1038/sj.bdj.2009.728
  4. Besimo C, Kempf B. In vitro investigation of various attachments for overdentures on osseointegrated implants. J Oral Rehabil 1995;22:691-8. https://doi.org/10.1111/j.1365-2842.1995.tb01068.x
  5. Meijer HJ, Kuiper JH, Starmans FJ, Bosman F. Stress distribution around dental implants: influence of superstructure, length of implants, and height of mandible. J Prosthet Dent 1992;68:96-102. https://doi.org/10.1016/0022-3913(92)90293-J
  6. Breitman JB, Nakamura S, Freedman AL, Yalisove IL. Telescopic retainers: an old or new solution? A second chance to have normal dental function. J Prosthodont 2012;21:79-83. https://doi.org/10.1111/j.1532-849X.2011.00797.x
  7. Kim IS, Kang DW, Kim BO, Yoo KH. Design and fabrication of inner Konus crown using three dimensional computer graphics. J Korean Acad Prosthodont 2000;38:544-51.
  8. Shimakura M, Nagata T, Takeuchi M, Nemoto T. Retentive force of pure titanium konus telescope crowns fabricated using CAD/CAM system. Dent Mater J 2008;27:211-5. https://doi.org/10.4012/dmj.27.211
  9. Miyazaki T, Hotta Y, Kunii J, Kuriyama S, Tamaki Y. A review of dental CAD/CAM: current status and future perspectives from 20 years of experience. Dent Mater J 2009;28:44-56. https://doi.org/10.4012/dmj.28.44
  10. Goodacre CJ. Palladium-silver alloys: a review of the literature. J Prosthet Dent 1989;62:34-7. https://doi.org/10.1016/0022-3913(89)90043-7
  11. Huget EF, Civjan S. Status report on palladium-silver-based crown and bridge alloys. J Am Dent Assoc 1974;89:383-5. https://doi.org/10.14219/jada.archive.1974.0426
  12. Bergler M, Holst S, Blatz MB, Eitner S, Wichmann M. CAD/CAM and telescopic technology: design options for implantsupported overdentures. Eur J Esthet Dent 2008;3:66-88.
  13. Beuer F, Schweiger J, Edelhoff D. Digital dentistry: an overview of recent developments for CAD/CAM generated restorations. Br Dent J 2008;204:505-11. https://doi.org/10.1038/sj.bdj.2008.350
  14. Kansu G, Aydin AK. Evaluation of the biocompatibility of various dental alloys: Part I-Toxic potentials. Eur J Prosthodont Restor Dent 1996;4:129-36.
  15. Ceragemgiosys. [cited 2015 February]. Available from:http://www.ceragembiosys.com