초록
Purpose: In order to fulfill the RAMS (Reliability Availability Maintainability and Safety) requirements in Korean railway systems, specific target metrics should be measured and met the requirements when ordering a new system. This paper presents a procedure to predict and demonstrate the availability, maintainability and safety of subway elevators, escalators and PSD (platform screen doors) systems. Methods: The system manufacturer predicts availability and maintainability with lab and field tested data. After installation, availability and maintainability are demonstrated based on the actual operational data. The data was collected from the FRACAS (Failure Report and Corrective Action System). Results: Methods and process of assessing and analyzing the availability, maintainability and safety are presented for elevating services and PSD systems. The data obtained through the actual operation of the equipment is analyzed and maintained to predict the RAMS based on the component and system level failure data acquired. Conclusion: This study presented an application using IEC 62278 and operational data which can be used in the design and development stage to achieve the RAMS target value of the subway elevators, escalators and PSD systems.