Abstract
A study of a precision test according to the control method of an injection molding machine was carried out. The effects of the screw stroke, holding pressure, melt temperature on both the hydraulic and electric injection molding machine were examined. In addition, hypothesis testing was performed to determine the deviation of the data obtained in the experiments. The conclusions obtained in this study were as follows. Significant deviations in the screw stroke, melt temperature and holding pressure occurred in that order. The hydraulic type showed significantly more variation between the products compared to the electric type. In addition, using a mini tab from the statistics program, a hypothesis was proposed and the P value of the injection stroke, holding pressure, melting temperature injection stroke and melting temperature had adopted a null hypothesis ($H_0$). The holding pressure, which showed mutual differences, adopted an alternative hypothesis ($H_1$).
본 연구는 사출 성형기의 제어 방법에 따른 정밀 검사에 대한 연구를 수행하였다. 실험을 통하여, 유압사출 성형기와 전동식 사출성형기의 스크루 스트로크, 보압, 용융 수지온도에 대하여 정밀도에 미치는 영향을 조사하였다. 또한, 실험에서 얻어진 데이터 편차에 대한 가설 테스트를 수행 하였다. 연구를 통하여 스크루 스트로크, 용융 수지온도, 보압 순으로 편차가 크게 발생하는 것을 알 수 있었다. 유압식 사출성형기가 전동식 사출성형기에 비해 제품 간의 산포가 크게 발생하는 것을 확인하였다. 또한 통계프로그램인 미니탭을 활용하여 스크루 스트로크, 용융 수지온도, 보압에 대한 가설을 설립 한 후 P값을 확인하여 스크루 스트로크, 용융수지온도는 귀무가설($H_0$)을 채택하였으며, 보압은 상호차이가 발생한 대립가설($H_1$)을 채택하였다.