Assessment of Structural Performance for a Lightweight Soundproof Tunnel Composed of Partitioned Pipe Truss Members

격벽화된 파이프 트러스 요소로 구성된 경량방음터널의 구조적 성능 평가

  • 노명현 (포스코 철강솔루션마케팅실 구조연구그룹) ;
  • 안동욱 (포스코 철강솔루션마케팅실 구조연구그룹) ;
  • 주형중 ((주)아이시스이엔씨)
  • Received : 2016.02.05
  • Accepted : 2016.02.29
  • Published : 2016.03.31

Abstract

In this paper, the full-size structural performance test for a lightweight soundproof tunnel composed of partitioned pipe truss members is carried out to investigate the structural performance. In addition, a nonlinear structural analysis of the same finite element model as the full-size testing model is performed to compare the test result. The test and analysis results showed that the lightweight soundproof tunnel ensures the structural safety against wind loads, snow loads and load combinations. As a result, the full-size test and analysis results meet all the design load conditions, hence the proposed lightweight soundproof tunnel is ready for the field application.