DOI QR코드

DOI QR Code

Study of Energy Cost for Performing Flush-out in Newly Constructed Multi-residential Buildings during Winter Season

겨울철 신축 공동주택의 플러쉬아웃 시행 시 난방비용에 관한 연구

  • Lee, Ki Yong (Graduate School of Architectural Engineering, Hanyang University) ;
  • Kim, Kee Han (Building and Urban Research Institute, Korea Institute of Civil Engineering and Building Technology) ;
  • Park, Jun-Seok (Department of Architectural Engineering, Hanyang University)
  • 이기용 (한양대학교 대학원 건축공학과) ;
  • 김기한 (한국건설기술연구원) ;
  • 박준석 (한양대학교 건축공학과)
  • Received : 2016.01.22
  • Accepted : 2016.03.02
  • Published : 2016.03.10

Abstract

Newly constructed multi-residential buildings with more than 500 households should be flushed out indoor contaminants using a mechanical ventilation system or large fans after the completion of construction and prior to occupancy by the Heath-friendly Housing Construction Standards since 2014. In addition, the standard recommends to maintain indoor temperature over $16^{\circ}C$ and relative humidity below 60% while performing the flush-out. However, it is difficult to maintain these recommended indoor conditions, especially during winter season because additional energy cost is needed for space heating. Therefore, in this study, additional energy cost including heating and ventilation energy cost in multi-residential household for flush-out during winter season was estimated using building energy simulation program called EnergyPlus. Additional energy cost according to various conditions for performing flush-out (such as performance period, ventilation rate, and heating set-point temperature) was analyzed. Based on the results of the energy simulation, the energy cost was estimated to be ranged from 14,625 to 29,452\/household in Incheon city and from 3,521 to 26,268\/household in Gwangju City. There was no significant change in energy cost according to the performing terms of flush-out between Incheon and Gwangju City.

Keywords

References

  1. MOLIT, 2014, Criteria for Health-friendly Housing Construction, Notice No. 2013-612, Ministry of Land, Infrastructure and Transport.
  2. Kim, K. H., Lee, K. Y., and Park, J. S., 2015, A Study on the Current Status and Improvement in Performing Flush-out in Multi-family Residential Buildings, Korean Journal of The Architectural Institute, Vol. 31, No. 8, pp. 129-137.
  3. DOE, Weather Data Sources, Department of Energy. (http://apps1.eere.energy.gov/buildings/energyplus/weatherdata_sources.cfm).
  4. KEPCO, 2013, Electric Cost Table, Korea Electric Power Corporation(http://cyber. kepco.co.kr).
  5. Korea City Gas Association, 2015, City Gas Cost Table(http://www.citygas.or.kr/).
  6. Lee, B. J. et al., 2003, Survey on Energy Consumption according to Heating Methods in Apartment Houses, Proceedings of the SAREK Winter Annual Conference, p. 118.
  7. Park, S. H. et al., 2014, A Survey on Energy Consumption through Operational Level in Apartment Buildings, Korean Journal of The Architectural Institute, Vol. 30, No. 2, pp. 233-240.
  8. Construction Cost Research Institute, Calculation Method for Ground Floor Construction Cost(http://www. anycost.or.kr).
  9. Lee, K. Y., Kim, K. H., and Park, J. S, 2015, An Analysis of Energy Cost for Performing Flush-out in Winter, Proceedings of The Architectural 2015 Annual Autumn Conference, Vol. 35, No. 2, pp. 59-60.