Abstract
In this study, we develop a model of an open center and load-sensing system and for a main control valve to analyze system characteristics and efficiency using SimulationX. In order to analyze the operating characteristics of the pressure and flow of the main control valve of an open center system, a test was performed at each port. The reliability of the model was confirmed by comparing the similarity of the analysis results with the test results before analyzing the operating characteristics of the system. Development of the load sensing main control valve was performed by adding a flow sharing valve and a notched shape to the open center system based on it's the proven reliability. The authors performed the simulation under the same load conditions in order to compare the efficiency of the systems. Additionally, the combined operation performance was investigated by means of analyzing the characteristics of flow distribution under different load conditions.
본 연구에서는 오픈센터 시스템과 부하 감지형 시스템의 해석모델을 개발하고 시스템의 특성과 효율을 분석하였다. 오픈 센터 방식의 메인 컨트롤 밸브의 압력과 유량 특성을 분석하기 위해 각각의 포트별로 시험을 수행하였다. 시스템의 특성 분석 전 단계에서 시험 결과와 해석 결과를 비교함으로써 해석모델의 신뢰성을 검토하였다. 신뢰성이 검증된 오픈 센터 방식의 메인컨트롤 밸브에 유량 분배 밸브를 추가하여 부하 감지형 메인 컨트롤 밸브의 해석모델을 개발하였다. 두 가지 시스템의 효율을 분석하기 위해 동일한 부하 조건에서 해석을 수행하였으며 각각의 부하 특성에 따른 효율을 검토하였다. 또한, 서로 다른 부하 조건에서 유량 분배 시스템의 특성을 분석함으로써 복합 동작에 대한 성능도 검토 하였다.