Since the 1980s, the number of large space buildings in Korea has consistently been increasing due to large scale international competitions such as the Olympics and the World Cup, demands for environmental improvement, and development of structural systems. Due to these reasons, this paper conducted a comparative analysis on terrorism risk factors of large space structure and skyscrapers in Korea. The results suggest that the total risk level of high-rise and large space structure was "medium level risk" and that the terrorism risk level for large space structure was as high as that for high-rise buildings. As it relates to the risk levels depending on scenarios, terrorism risks to large space structure were higher than high-rise buildings in the "internal explosion" and "internal intrusion" categories. And the results of analyzing explosion-related scenarios except for CBR suggest that terrorism risks to large space structure were highest when it comes to Internal-Explosive followed by Internal-Intrusion and Explosive-Zone I; and the results showed a regular pattern. On the other hand, in the case of high-rise buildings, terrorism risks were highest in Internal-Explosive followed by Explosive-Zone I and Explosive-Zone II; and the results showed an irregular pattern.

Keywords

References

  1. Cho Hong-Sick.,"A terrorist attack on Paris by IS and the war against terrorism by France", The check of pending issues by the Korea National Strategy Institute, 2015, No. 288.
  2. Do Gi-Young., Yoon Sung-Won., "Explosive- Terror Risk Curve by RVS", Journal of the Korean Association for Spatial Structures, Vol. 13, No. 3, 2013, PP. 57-64. https://doi.org/10.9712/KASS.2013.13.3.057
  3. Kim Du-Hyeon., Ahn Kwang-Ho., "Counterterrorism Safety Measures in Public Facilities", The Journal of the Korea Security Science Association, No. 22, 2010, PP.37-64.
  4. Yu Young-Su., Yoon Sung-Won., Ju Young Kyu., "Risk Assessment of Tall Buildings in Korea by comparative study of Modified RVS and IRVS system", Journal of the Korean Association for Spatial Structures, Vol. 12, No. 4, 2012, PP.91-98. https://doi.org/10.9712/KASS.2012.12.4.091
  5. Song Jin-Young., Yoon Sung-Won., "Analysis on the Risk of Explosive Terror in Domestic Buildings", Journal of the Korean Association for Spatial Structures, Vol. 12, No. 2, 2012, PP.73-80. https://doi.org/10.9712/KASS.2012.12.2.073
  6. Lee Ju-Na., "A Study on the Establishment Feature and the Development of Large Buildings in Korea ", Journal of the korean Association for Spatial Structures, Vol. 9, No. 2, 2009, PP.65-75.
  7. FEMA., "FEMA 455-Handbook for Rapid Visual Screening of Buildings to Evaluate Terrorism Risks", 2009.
  8. FEMA., "FEMA 426-Reference Manual to Mitigate Potential Terrorist Attacks Against Building", 2003.
  9. FEMA.,"FEMA 452-Risk Assessment, A How to Guide to Mitigate Potential Terrorist Attacks Against Buildings", 2005.
  10. Song Jin-Young., Yoon Sung-Won., "A Comparative Analysis of Terrorism Threet Level of Domestic Tall Buildings and General Buildings Through Rapid Visual Screening", Journal of the korean Association for Spatial Structures, Vol. 11, No. 4, 2011, PP.89-99. https://doi.org/10.9712/KASS.2011.11.4.089