Abstract

Generally, in order to implement the CRM(Critical Conduction Mode), the analog controller is used rather than a digital controller because the control is simple and uses less power. However, according to the semiconductor technology development and various user needs, digital control system based on a DSP is on the rise. Therefore, in this paper, the CRM bridgeless PFC converter based on a digital control is proposed. It is necessary to detect the inductor current when it reaches zero and peak value, for calculating the on time and off time by using the current information. However, in this paper, the on-time and off-time are calculated by using the proposed algorithm without any current information. If the switching-times are calculated through the steady-state analysis of the converter, they do not reflect transient status such as starting-up. Therefore, the calculated frequency is out of range, and the transient current is generated. In order to solve these problems, limitation method of the on-time and off-time is used, and the limitation values are varied according to the voltage reference. In addition, in steady state, depending on the switching frequency, the inductance is varied because of the resonance between the inductor and the parasitic capacitance of the switching elements. In order to solve the problem, inductance are measured depending on the switching frequency. The measured inductance are used to calculate the switching time for preventing the transient current. Simulation and experimental results are presented to verify the proposed method.

Keywords

References

  1. L. Huber, Y. Jang, and M. M. Jovanovic, "Performance evaluation of bridgeless PFC boost rectifiers," IEEE Trans. Power Electron, vol. 23, no. 3, pp. 1381-1390, May 2008. https://doi.org/10.1109/TPEL.2008.921107
  2. F. Musavi, W. Eberle, and W. G. Dunford, "A highperformance singlephase bridgeless interleaved PFC converter for plug-in hybrid electric vehicle battery chargers," IEEE Trans. Ind. Appl., vol. 47, no. 4, pp. 1833-1843, Jul./Aug. 2011. https://doi.org/10.1109/TIA.2011.2156753
  3. L. Huber, B. T. Irving, and M. M. Jovanovic, "Closed-loop control methods for interleaved DCM /CCM boundary boost PFC converters," in Proc. IEEE Appl. Power Electron. Conf. pp. 991-997, Feb. 2009.
  4. X. Xiaojun, L. Wei, and A. Q. Huang, "Two-phase interleaved critical mode PFC boost converter with closed loop interleaving strategy," IEEE Trans. Power Electron, vol. 24, no. 12, pp. 3003-3013, Dec. 2009. https://doi.org/10.1109/TPEL.2009.2019824
  5. J. Zhang, J. Shao, F. C. Lee, and M. M. Jovanovic, "Evaluation of input current in the critical mode boost PFC converter for distributed power systems," in Proc. IEEE Applied Power Electronics Conf. (APEC), pp. 130-136, Feb. 2001.
  6. Byung-Gyu Yu, Sung-Se Lee, Sang-Kyu Han, Gun-Woo Moon. "Boundary Current Mode Operated Bridgeless Boost Converter for Power Factor Correction." Power Electronics Annual Conference, pp. 90-94, Nov. 2003.
  7. D. S. Padimiti and M. Ferdowsi, "Review of Digital Control Techniques for Automotive DC-DC Converters," IEEE Vehicle Power and Propulsion Conference, pp. 653-657, 2005.
  8. X. Huang, T. Nergaard, J. S. Lai, X. Xu, and L. Zhu, "A DSP based controller for high-power interleaved boost converters," in Proc. IEEE Applied Power Electronics Conf. (APEC), pp. 327-333, Mar, 2003.