DOI QR코드

DOI QR Code

A Study on Performance Evaluation of a Vertically Closed Deep Geothermal Circulation Simulator

수직 밀폐형 심부지열 순환 시뮬레이터의 성능 평가에 관한 연구

  • 배정형 (조선대학교 기계공학과) ;
  • 이동운 (조선대학교 기계공학과) ;
  • 윤충만 (조선대학교 기계공학과) ;
  • 류연수 (한국농어촌공사 농어촌연구원) ;
  • 정상화 (조선대학교 기계공학과)
  • Received : 2016.07.13
  • Accepted : 2016.07.29
  • Published : 2016.10.31

Abstract

While greenhouses have been utilized as a sustainable alternative to traditional soil farming, they are often powered by diesel boilers that necessitate vast amounts of non-renewable energy and emit toxic fumes. Thus, geothermal heat pumps have been proposed as a more energy-efficient substitution for diesel boilers. Currently, most horticultural facilities in the United States use shallow geothermal systems, and are often equipped with horizontal underground heat exchangers as well as heat pump equipment. These shallow geothermal systems require a large drilling site and heat pump to function, which results in high maintenance costs. The heat pump itself consumes a large amount of power, which degrades system performance. Conversely, high temperatures can be attained within a single borehole in deep geothermal vertical closing systems without using a heat pump. This setup can dramatically reduce the power consumption and improve system performance. In this study, we have modeled a circulation simulator after the circulation systems in deep geothermal facilities to analyze a 2000-meter borehole in Naju-Sanpo-myeon. The simulator is operated by manipulating various putative parameters affecting system performance to analyze the system's coefficient of performance.

Keywords

References

  1. Ryoo, Y. S., "A Study on the Loadsharing for Geothermal Heat pump System and Boiler in Horticultural Greenhouse," Rural Research Institute, 11-D150769-000025-01, pp.8-13, 2012.
  2. Kim, S. S., 'A Study on the Heat Pump System by Using Geothermal Energy', Department of Mechanical & Precision Engineering Graduate School Gyeong Sang National University , 2010.
  3. Sohn, B. H., "Performance Analysis of Ground-Coupled Heat Pump System with Slinky-Type Horizontal Ground Heat Exchanger," Korean Journal of Air-Conditioning and Refrigeration Engineering 24(3), pp.230-239, 2012. https://doi.org/10.6110/KJACR.2012.24.3.230
  4. Bae, J. H., "A Study on the Deep-geothermal Water Simulation Monitoring using LabVIEW," KSMPE Conference, pp.202-202, 2016.
  5. Sohn, B. H., Cho, C. S., Shin, H. J., and An, H. J., "Cooling and heating performance evaluation of a GSHP system, Korean Journal of Air-conditioning and Refrigeration Engineering," Vol. 17, No. 1, pp.71-81, 2005.
  6. Sohn, B. H., Choi, J. M., and Choi, H., "Performance Simulation of Ground-Coupled Heat Pump(GHP) System for a Detached House, Korean journal of Air-conditioning and Refrigeration Engineering, Vol 23, No. 6, pp.392-399, 2011. https://doi.org/10.6110/KJACR.2011.23.6.392
  7. Lee, J. Y., Chung, J. T. Woo, J., and Choi, J. M., "Influence of the Secondary Fluid Glow rate of the Performance of a GSHP System, Korean Journal of Air-conditioning and Refrigeration Engineering, Vol. 22, No.10, pp.649-656, 2010.
  8. Kang, S. H., Choi, J. M., Moon, J., and kWon, H., "Heating Performance of a Ground source Multi-heat pump for a Greenhouse, Korean Journal of Air-conditioning and Refrigeration Engineering, Vol.22, No. 6, pp.337-344, 2010.
  9. Kim, H. C., and Lee, Y. G., 'Heat flow in the Republic of KOREA', Journal of Geophysical Research, Vol.112, B05413, doi:10.1029/2006JB009, pp.266. 2007.
  10. Chae, H. B., and Nam, Y. J., Kim, D. K., 'Study on the experimental analysis for a hybrid heat pump using the renewable heat source', The Society Of Air-Conditioning And Refrigerating Engineers Of Korea, Conference of Autumn, pp.416-419. 2013.
  11. Jung, S. H., and Kim, D. G., Gong, S. H., 'Development of Electrical and Oil Heater for energy saving', Journal of the Korean Society of Manufacturing Process Engineers, Vol.10, No.5, pp.38-43. 2011.
  12. Jung, S. H., 'Thermal Insulation Property due to Internal Air-layer Content of Warm Multi Layer Materials by using Numerical Analysis', Journal of the Korean Society of Manufacturing Process Engineers, Vol.11, No.4, pp.97-103. 2012.
  13. Lee, C. H., and Kim, D. M., Yang, H. S., Kim, S. J., 'Design and Analysis of Cryogenic Turbo Expander for HTS Power Cable Refrigeration system', Journal of the Korean Society of Manufacturing Process Engineers, Vol.14, No3, pp.141-148. 2015. https://doi.org/10.14775/ksmpe.2015.14.3.141
  14. Lee, S. H., and Moon, H. J., Hue, S. B., Choi, S. D., 'Development of LED Module Control-based PWM Current for Control of Heat-dissipation', Journal of the Korean Society of Manufacturing Process Engineers, Vol.14, No.6, pp.129-135. 2015. https://doi.org/10.14775/ksmpe.2015.14.6.129